· HMS-2000C-4T *Note: “1600” means peak power 1600 W, “1800” means peak power 1800 W, “2000” means peak power 2000 W. *Note: HMS-1600C/1800C/2000C-4T is only compatible with Hoymiles gateway DTU-Pro-S and DTU-Lite-S. 1.2 Target Group This manual is only for qualified technicians. For safety purposes, only those who have been trained or demonstrate relevant skills can install and maintain this microinverter under the guidance of this document.
All repairs must be done with qualified spare parts which must be installed in accordance with their intended use and by a licensed contractor or authorized Hoymiles service representative. • Liabilities arising from components that are not produced by Hoymiles are on the part of their re- spective manufacturers. •...
Moreover, microinverter only carries a few dozen volts of DC voltage (less than 80 volts), which reduces safety hazards to the greatest extent. Hoymiles microinverters feature module-level monitoring. Microinverter data are collected by DTU via wireless transmission and are sent to Hoymiles motoring platform S-Miles Cloud.
Sub-1G Microinverter This manual is about Hoymiles 4-in-1 microinverter. With the output power up to 2000 VA, Hoymiles new HMS-2000C series rank among the highest for 4-in-1 microinverters. Each microinverter connects to four PV modules at most with dual MPPT and modules-level monitoring, en- abling greater energy harvest and easier maintenance.
Hoymiles HMS-1600C-4T/HMS-1800C-4T/HMS-2000C-4T can be used with 12AWG or 10AWG AC Trunk Ca- ble and the AC Trunk Connector which are provided by Hoymiles. The number of microinverters on each 12AWG or 10AWG AC branch shall not exceed the limit as shown below.
Page 14
A ) Select the appropriate AC Trunk Cable according to the spacing between microinverters. The connec- tors of the AC Trunk Cable should be spaced based on the spacing between microinverters to ensure that they can be properly matched. (Hoymiles provides AC Trunk Cable with different AC Trunk Con- nector spacing.) B ) Determine how many microinverters you plan to install on each AC branch and prepare AC Trunk Connectors accordingly.
1.Check if the grid configuration parameter is correct and upgrade. Grid configuration parameter error 2. If the fault still exists, contact your dealer or Hoymiles technical support team. 1.Check if the firmware is correct and has been upgraded. 2.Check the communication between DTU and Hoymiles monitoring system, and between DTU and microinverter.
Page 18
If not, contact the local power operator or change the grid frequency change rate limit the grid profile in the grid profile via Hoymiles monitoring system with the consent of the local power operator.
Page 19
MPPT-B Input undervoltage 2. If the PV module open-circuit voltage is within the normal range, contact your dealer or Hoymiles technical support team. 1. Please confirm whether this port is connected to the PV module. PV-1 No input 2.
1. The microinverter is powered by the DC side. If the LED light is not on, please check the DC side connection. If the connection and input voltage are normal, contact your dealer or Hoymiles technical support team. 2. All the faults are reported to the DTU. Refer to the local DTU app or Hoymiles Monitoring Platform for more information.
Make sure that PV modules’ DC voltage is within the allowable range shown in the Technical Data section of this manual. If the problem persists, please call Hoymiles customer support. Do not try to repair the microinverter by yourself. If the troubleshooting fails, please return it to the factory for replacement.
5 kg and can be fully closed. 7.2 Storage and Transportation Hoymiles packages are specially designed to protect components so as to facilitate transportation and subsequent handling. Transportation of the equipment, especially by road, must be done in a way that can protect the components (particularly the electronic components) from violent shocks, humidity, vibration, etc.
Single-phase Microinverter HMS-1600C/1800C/2000C-4T Technical Data 8. Technical Data Be sure to verify the following before installing Hoymiles Microinverter System. Verify that the voltage and current specifications of the PV module match those of the microinverter. • The maximum open circuit voltage rating of the PV module must be within the operating voltage range of the microinverter.