Download Print this page

Datalogic LT-700 Quick Start Manual

Linear array lighting system

Advertisement

Quick Links

LT-700 LINEAR ARRAY
LIGHTING SYSTEM
DESCRIPTION
The LT-700 Linear Array Lighting System provides a high intensity light
source designed for the following applications:
with uneven, noisy and scratched surfaces
where dot peening or laser etching codes are directly marked onto
metal surfaces or PCBs and need to be highlighted. Here the use
of more than one LT-700 at different positions can remove any
shadowing effect.
in the presence of highly reflective surfaces (metal, glass, etc.)
causing direct reflections. Low light path to surface angles strongly
reduce direct reflections.
MECHANICAL DIMENSIONS
33
68
[1.28]
[2.68]
31.0
54.0
[1.22]
[2.13]
M 3 n°2
DEPTH 5
15.5
8.0
[0.61]
[0.31]
54.0
[2.13]
M 3 n°2
DEPTH 5
Matrix 210™ Straight Model
The Matrix 410™ reader does not mount directly to the
BK-21-000 bracket.
NOTE
WIRING
M 3 n°2
DEPTH 5
8.0
15.5
Wire Color
CBX/Matrix Signal
[0.31]
[0.61]
Red
Vdc
Black
GND
White
Earth
mm
Green
O1- or O2-
[inch]
Yellow
O1+ or O2+
Matrix 210™ 90° Model
Matrix 410™
Meaning
10 to 30 Vdc
Ground
Shield/Earth Ground
Control Signal -
Control Signal +
MOUNTING LT-700
The following parts are required for mounting:
LT-700 Linear Array Lighting System
Accessory BK-21-000 LT-700 Fixing Bracket
A
C
D
Example BK-21-000 Assembly
A
1.
Mount the rotating bracket
(2 pieces) onto the Reader Mounting
B
B'
Bracket
(for straight models) or
the M3 screws. Do not completely tighten the screws.
C
2.
Mount the LT-700 sliding bracket
using 2 of the M3 screws and 2 washers. Do not completely
tighten the screws.
D
3.
Mount the LT-700
onto the LT-700 sliding bracket
the M3 screws and 2 washers. Do not completely tighten the
screws.
4.
Mount the Matrix 210™ reader to the Reader Mounting Bracket
B'
(for straight models) or
(for 90° models).
If LT-700 is used with Matrix 410™, the reader must be mounted
separately.
5.
Mount the entire assembly to the reading station frame (i.e. Bosch
profile).
6.
Wire the LT-700 to the CBX according to the Wiring table.
7.
Follow the Positioning instructions in the following paragraph.
B
B'
(for 90° models) using 2 of
A
onto the rotating bracket
C
using 2 of
B

Advertisement

loading

Summary of Contents for Datalogic LT-700

  • Page 1 CBX/Matrix Signal Meaning [0.31] [0.61] [0.61] [0.31] 10 to 30 Vdc If LT-700 is used with Matrix 410™, the reader must be mounted separately. Black Ground White Earth Shield/Earth Ground Mount the entire assembly to the reading station frame (i.e. Bosch 54.0...
  • Page 2 By reducing clearance, LT-700 can be positioned closer to  © 2012 - 2017 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS RESERVED.  Without limiting the the code surface to maximize illumination. rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a...