Download Print this page

Datalogic SG2-B Series Quick Manual

Safety light curtains with infrared beams

Advertisement

Quick Links

 The stopping system of the machine must be electrically controlled.
 This control system must be able to stop the dangerous movement of the machine within the total machine stopping
time T as per par. 1.1.3 of the manual included in the CD supplied and during all working cycle phases.
 Mounting and connection of the safety light curtain must be carried out only by qualified personnel, according to the
indications included in the special sections (refer to sections 2; 3; 4; 5) and in the applicable Standards.
 The safety light curtain must be securely installed so that access to the dangerous zone is not possible without
interrupting the beams (see section 2 "Installation mode").
 The personnel operating in the dangerous area must be well trained and must have adequate knowledge of all the
operating procedures of the safety light curtain.
 The TEST/RESET button must be located outside the protected area as the operator must check the protected area
during all Test and Reset operations.
 Please carefully read the instructions for the correct functioning before powering the light curtain.
Precautions to be observed for the choice and installation of the device
Make sure that the protection level assured by the SG2 device (Type 2) is compatible with the real danger
 The outputs (OSSD) of the ESPE must be used as machine stopping devices and not as command devices. The
machine must have its own START command.
 The dimension of the smallest object to be detected must be larger than the resolution level of the device.
 The ESPE must be installed in a room complying with the technical characteristics indicated in chapter 10 "Technical
data" of the manual included in the CD supplied.
 Do not place the device near intense and/or flashing light sources and, in particular, close to receiving unit front surface.
 The
presence
of
This condition has to carefully evaluated with the support of the DATALOGIC AUTOMATION Technical service.
 The operating distance of the device can be reduced in presence of smog, fog or airborne dust.
 A sudden change in environment temperature, with very low minimum peaks, can generate a small condensation layer
on the lenses and so jeopardise functioning.
The failure to respect the safety distance reduces or cancels ESPE the protection function.
For more detailed information about calculation of safety distance,please refer to the complete manual
SAFETY INFORMATION
The following points must be observed for a correct and safe use
of the safety light curtains of the SG2 series:
level of the machine to be controlled, according to EN 954-1 and EN 13849-1.
intense
electromagnetic
contained in the CD supplied.
SG2-B SERIES
Safety light curtains with infrared beams
QUICK GUIDE
disturbances
could
1
jeopardise
device
operation.

Advertisement

loading

Summary of Contents for Datalogic SG2-B Series

  • Page 1 This condition has to carefully evaluated with the support of the DATALOGIC AUTOMATION Technical service.  The operating distance of the device can be reduced in presence of smog, fog or airborne dust.  A sudden change in environment temperature, with very low minimum peaks, can generate a small condensation layer on the lenses and so jeopardise functioning.
  • Page 2 CONNECTIONS RECEIVER (RX) EMITTER (TX) NOT USED +24 VDC OSSD1 +24 VDC TEST/RESET NOT USED OSSD2 1 = brown = +24 VDC 1 = brown = +24 VDC 2 = white = OSSD 1 2 = white = NOT USED 3 = blue = 0V 3 = blue...
  • Page 3 Switch OFF and switch ON the supply circuit; if the failure continues contact yellow BLINKING) DATALOGIC AUTOMATION Error status Optical error (red ON yellow BLINKING) Reset. If the failure continues contact DATALOGIC AUTOMATION No power supply Check connections and input voltage correct value. (LEDs OFF) If the failure continues contact DATALOGIC AUTOMATION...
  • Page 4 WARRANTY DATALOGIC AUTOMATION warrants its products to be free from defects. DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION products.