Download Print this page

Datalogic SG-BODY Series Quick Manual

Safety light curtains with infrared beams

Advertisement

Quick Links

This Quick Reference Guide does not replace the Instruction Manual. Download
the Instruction Manual by reading the QR code here or at www.datalogic.com.
Click on Support > Search by product and enter the SG
select your product from the dropdown list. Click on the Manuals & Technical
Literature link to download your Instruction Manual. The Instruction Manual must
be available at all times when installing and working with the product.
The following points must be observed for a correct and safe use of the safety light curtains of the SG-
BODY series:
 The stopping system of the machine must be electrically controlled.
 This control system must be able to stop the dangerous movement of the machine within the total machine stopping
time T as per paragraph 2.4.3 of the Instruction Manual and during all working cycle phases.
 Mounting and connection of the safety light curtain must be carried out only by qualified personnel, according to the
indications included in the special sections (refer to sections 3; 4; 5; 7) and in respect to the applicable Standards.
 The safety light curtain must be securely installed so that access to the dangerous zone is not possible without
interrupting the beams.
 The personnel operating in the dangerous area must be well-trained and must have adequate knowledge of all the
operating procedures of the safety light curtain.
 The TEST, RESET/RESTART and OVERRIDE buttons must be located outside the protected area as the operator must
check the protected area during all Test, Restart and Override operations.
 Please carefully read the instructions for the correct functioning before powering the light curtain.
Precautions to be observed for the choice and installation of the device
Make sure that the protection level assured by the SG-BODY device (Type2/Type4) is compatible with the
real danger level of the machine to be controlled, according to EN 13849-1.
 The outputs (OSSD) of the ESPE must be used as machine stopping devices and not as command devices. The
machine must have its own START command.
 The dimension of the smallest object to be detected must be larger than the resolution level of the device.
 The ESPE must be installed in a room complying with the technical characteristics indicated in section 11 "Technical
data" of the Instruction Manual.
 Do not place the device near intense and/or flashing light sources and, in particular, close to receiving unit front surface.
 The presence of intense electromagnetic disturbances could jeopardise device operation. This condition has to be
carefully evaluated with the support of the Datalogic Technical service.
 The operating distance of the device can be reduced in presence of smog, fog or airborne dust.
 A sudden change in environment temperature, with very low minimum peaks, can generate a small condensation layer
on the lenses and so jeopardise functioning.
 Reflecting surfaces near the safety light curtain light beam (above, under or lateral) can cause passive reflections that
can jeopardise functioning.
 The safety device must be installed at a distance which is major or equal to the minimum safety distance S to ensure
that the operator can not reach the dangerous area until the moving dangerous object has been blocked by the ESPE.
The failure to respect the safety distance reduces or cancels ESPE the protection function. For more detailed
information about calculation of safety distance, please refer to the Instruction Manual.
SG-BODY MUTING SERIES
Safety light curtains with infrared beams
SAFETY INFORMATION
1
QUICK GUIDE
BODY
family name, then

Advertisement

loading

Summary of Contents for Datalogic SG-BODY Series

  • Page 1 Safety light curtains with infrared beams QUICK GUIDE This Quick Reference Guide does not replace the Instruction Manual. Download the Instruction Manual by reading the QR code here or at www.datalogic.com. Click on Support > Search by product and enter the SG BODY family name, then select your product from the dropdown list.
  • Page 2 CONNECTIONS RECEIVER (RX) EMITTER (TX) N. C. external cont act +24 Vdc EARTH MUTING OSSD2 ENABLE OVERRIDE1 OSSD1 N.C. Error! Objects cannot be created from editing field 0 V / 24 V (*) OVERRIDE2 codes. RESET / RESTART/ RESTART MODE +24 Vdc Error! Objects cannot be created from editing field OVERRIDE STATUS...
  • Page 3: Alignment Procedure

    ALIGNMENT PROCEDURE The alignment between the emitting and the receiving units is necessary to obtain the correct functioning of the light curtain. A good alignment prevents output instability caused by dust or vibrations. The alignment is perfect if the optical axes of the first and the last emitting unit beams coincide with the optical axes of the corresponding elements of the receiving unit.
  • Page 4 A Keep the receiver in a steady position and set the emitter until the yellow LED ( SYNC) is OFF. This condition shows the effective alignment of the first beam (synchronisation beam). B Rotate the emitter, pivoting on the lower optics axis, until the yellow LED ( LAST) is OFF.
  • Page 5: Dip Switches Configuration

    DIP SWITCHES CONFIGURATION The device does not accept configuration changes during normal functioning. A change is accepted only beginning from the successive powering of the device. Particular attention has to be taken during the configuration dip-switch management and use.  Muting time-out “...
  • Page 6 FAILURE LOCKOUT switching device and activate EDM failure, OSSDs OFF (recoverable) RESET line. If ESPE does not reset user must contact Datalogic Automation Technical Support. User must check Override lines connection and turn OFF/ON ESPE. FAILURE LOCKOUT Override connection failure,...
  • Page 7 User must check dip-switch configuration and turn LOCKOUT Dip switch failure OFF/ON ESPE. If the problem persists user must contact Datalogic. (not recoverable) User must check power supply connection. If the ESPE OFF Power supply failure problem persists user must contact Datalogic.
  • Page 8 The warranty period for this product is 36 months. See General Terms and Conditions of Sales for further details. Under current Italian and European laws, Datalogic is not obliged to take care of product disposal at the end of its life.