Electrical Specifications; Standard Operation; Edge Lighting - Energizer Homepower HP-6M Series Owner's Manual

Table of Contents

Advertisement

Electrical Specifications

The Energizer Homepower HP-6 Series system can intelligently control the charge and discharge based on several
parameters including connected loads, solar generation, and external environmental conditions. It is sensitive
to the temperature variations & may limit charge or discharge based on internal cell temperature. Therefore, it is
recommended to avoid installations in locations that may be directly exposed to sunlight for prolonged periods of
time, and/or locations with sustained high or low temperatures. The Energizer Homepower HP-6 Series units are
designed to operate optimally in an average ambient temperature range between 0 °C to 30 °C.
Homepower Series
HP-6M
HP-6M/1S
Rated Energy
(kWh)
6.14
1
Usable Capacity
(kWh)
5.8
2
Dimensions
1244/420/183 1244/646/183 1244/872/183 1244/1098/183 1244/222/183
(H/W/D; mm)
Weight (kg):
98.5
Ingress Protection
OTR
(Operating
4
Temperature Range)
Recommended OTR
Protection Class
Operating Altitude Range
Operating Humidity (RH)
Mains Connection
Inverter
Nominal Output Voltage (V)
Nominal AC Frequency (Hz)
PF Range
Nominal Power (W)
Nominal AC Current (A)
Cooling
Rated Energy is determined as per battery standard IEC 62619:2017.
1
Usable Capacity is calculated as 95% of Rated Energy.
2
HP-6S unit is considered a sub-system of the Main Unit (HP-6M) and is never installed in a stand-alone manner.
3
Performance de-rating expected in extreme ambient temperature.
4
Table 1. Technical Specifications (HP-6 Series)
V23-00211
Energizer Homepower HP-
HP-6M/2S
HP-6M/3S
12.28
18.42
24.56
11.6
17.4
23.2
168.5
238.5
308.5
IP65
Charge: 0 to 45 °C,
Discharge: -20 to 50 °C
0 to 30 °C
Class I
<2000 m
0 - 95%
Single-phase, L/N/PE
230 V a.c.
50 Hz (Self-Adapting)
1 (adj 0.8 leading - 0.8 lagging)
3600 W
16 A
Natural Convection
12
© Energizer 2021
6
Series
Energizer Homepower HP-
Homepower Series
Battery
Battery Type
Rated Capacity
Nominal Voltage
Max Current
Additional Features
Supported Communication
Interfaces
Monitoring
HP-6S
3
Rated Capacity is determined as per battery standard IEC 62619:2017.
5
6.14
5.8
70.0

Standard Operation

The Energizer Homepower HP-6 Series system is designed for both indoor & outdoor installations and can be
monitored using a variety of interfaces including Edge Lighting, an LCD panel, the Energizer Homepower App
and Customer Portal.

Edge Lighting

The Edge Lighting is designed to convey at-a-glance
information about system operating states such as
Normal, Stand-by and Fault.
Fig. 4. Energizer Homepower HP-6 Series Edge Lighting
V23-00211
6
Series
HP-6M
HP-6M/1S
HP-6M/2S
LFP (Lithium Iron Phosphate)
120 Ah
240 Ah
5
51.2 V d.c.
71 A d.c.(charge/discharge)
2.4G Wi-Fi, Ethernet, Cellular/4G (to Cloud)
Energizer Homepower Monitoring (App & Web platform)
Table 1. Technical Specifications (HP-6 Series)
13
HP-6M/3S
HP-6S
360 Ah
480 Ah
120 Ah
© Energizer 2021