8. Exposure Controls & Personal Protection
8.1. Control Parameters
8.1.1.
Occupational Exposure Limit Values:
Component
Country/Region
ppm
USA (OSHA)
-
South Korea
-
Aluminium
Ireland
-
7429-90-5
Germany (DFG)
-
Denmark
-
Australia (SWA)
-
USA (OSHA)
-
South Korea
-
Graphite
Ireland
-
7782-42-5
Germany (DFG)
-
Denmark
-
Australia (SWA)
-
Netherlands
-
Copper
Poland
-
7440-50-8
Latvia
-
Germany (DFG)
-
8.1.2.
Biological Limit Values: no information available
Biological
Component
Source
Monitoring Index
Phosphate (1-),
hexafluoro-,
SCOEL (EU)
Fluoride in Urine
Lithium
8.1.3.
Monitoring Methods
EN 1402 Workplace Atmospheres – guide for the application and use of procedures
for the assessment of exposure to chemical and biological agents.
GBZ/T 160.1 ~ GBZ/T 160.81-2004 Determination of toxic substances in workplace
air (Series standard).
V23-00211
Energizer Homepower HP-
Limit Value
Eight Hours
Short Term
mg/m3
ppm
mg/m3
15
-
10
-
1
-
4
-
5
-
10
-
15
-
2
-
10
-
4
-
2.5
-
3 (4)
-
0.1
-
0.2
-
0.5
-
0.01
-
0.02
Biological Limits
Sampling Time
Remark
Value
8mg/L
End of shift
28
© Energizer 2021
6
Series
Energizer Homepower HP-
8.2. Exposure Controls
8.2.1.
Engineering Controls
Ensure adequate ventilation, especially in confined areas.
Ensure that eyewash stations and safety showers are close to the workstation.
Use explosion-proof electrical/ventilating/lighting/equipment.
Setup emergency exit and necessary risk-elimination area.
8.3. Personal Protective Equipment
8.3.1.
Eye Protection: well fitted Safety Glasses (worn under shield), as approved by EN 166 (EU)
or NIOSH (US).
-
8.3.2.
Hand Protection: leather and voltage rated gloves in accordance with EN 374 (EU),
-
US F739 or AS/NZS 2161.1.
-
-
8.3.3.
Respiratory Protection: airborne exposure to hazardous substances in the electrolyte is not
10
expected when the cells of batteries are used for their intended purposes. In case of battery
-
venting or if exposure limits are exceeded, use a full-face respirator type AXBEK (EN 14387).
8.3.4.
Skin and Body Protection: arc-rated long sleeve shirt, arc-rated pants or overalls, arc-rated
-
face shield with hard-hat, hearing protection and leather work shoes, in accordance with
-
AS/NZS 5139.
-
-
9. Physical and Chemical Properties
5
-
9.1. Appearance: lithium ion batteries enclosed within protective metal case.
9.2. Nominal Voltage: 51.2V.
-
9.3. Rated Capacity: 120Ah.
-
9.4. Odour: no information available.
1
9.5. Melting Point or Freezing Point (°C): no information available.
9.6. Flammability: no information available.
9.7. pH: no information available.
9.8. Evaporation rate: no information available.
10. Stability & Reactivity
10.1.
Chemical Stability: stable under proper operation & storage conditions.
-
10.2.
Reactivity: contact with incompatible substances can cause decomposition or other
chemical reactions.
10.3.
Possibility of Hazardous Reactions: exposed ultra-fine powder may self-ignite in room-temperature.
Mixtures with metallic acetylene, when heated, cause a fire or incandescence. Reacts severely
with halogens, interhalogen or other strong oxidants.
10.4.
Conditions to Avoid: avoid exposure to heat and open flame, heating, mechanical (mutilation,
crushing and disassembly) and electrical (short circuit) abuse.
10.5.
Materials to Avoid: oxidants, halogen, interhalogen and mercury, metal acetylide, halogen oxides,
nitric acid, nitrous oxide, nitrates, nitrites, halogen oxyacid salts, chromates, permanganates,
inorganic peroxides, metal oxides, peroxyboric acid, water, corrosives, acids and alkalis.
10.6.
Hazardous Decomposition Products: under normal conditions of operation and storage, no
hazardous decomposition products are produced.
V23-00211
6
Series
29
© Energizer 2021

Advertisement