Step 2 – Shut Down Sequence (HP-6M/HP-6S)
In order to power off the Energizer Homepower HP-6 Series system completely, you will be required to follow
the procedure listed below, in conjunction with the technical advice received from your system provider.
Energizer Homepower HP-6 Series are not user serviceable and repairs must not be carried out by
system owners. Do not open the Installer Access Panel inside either the Main Unit or Sub Unit as
exposed wiring can present a risk of electrical shock.
1. If Backup/UPS loads are connected, turn off respective AC Isolators.
a. If applicable, turn off any AC Isolators connected on the backup side.
2. Turn off the Main AC Isolator, connected to the Energizer Homepower HP-6 Series system.
a. If applicable, turn off any AC Isolators connected on the grid side.
3. Turn off the Battery Isolators on all connected units as described below:
a. Lift the Magna-Flap on the HP-6M as shown in Fig. 14. to uncover the Installer Access Panel, housing
the Battery Isolator and the LCD.
Note: On the Battery Isolator, Red indicates ON and Green indicates OFF.
Fig. 14. HP-6M Magna-Flap & Installer Access Panel
b. If HP-6S unit(s) are installed, lift the Magna-Flap to uncover the Installer Access Panel, housing the
Battery Isolator.
Fig. 15. HP-6S Magna-Flap & Installer Access Panel
V23-00211
6
Energizer Homepower HP-
20
© Energizer 2021
Series
Energizer Homepower HP-
c. The Magna-Flaps on the HP-6M (and HP-6S) units shall magnetically attach to the metal casing/body
of the unit directly above.
The recommended sequence for turning on the Battery Isolators is HP-6M first,
followed by the adjacent HP-6S units.
4. Press and hold the ON/OFF Switch on the HP-6M, until a long buzzer noise is heard. Repeat the same for all
connected HP-6S unit(s). At this stage, you have powered off the Energizer Homepower HP-6 Series systems.
5. Return the Magna-Flaps to their original position on the HP-6M and all connected HP-6S units.
Step 3 – Power On Sequence (HP-6M/HP-6S)
In order to power on the Energizer Homepower HP-6 Series system, you will be required to follow the procedure
listed below:
1. Press and hold the ON/OFF Switch on the HP-6M, until a short buzzer noise is heard in conjunction
with a flicker of the Edge Lighting. Repeat the same for all connected HP-6S units. At this stage, you
have powered on the Energizer Homepower HP-6 Series system.
2. Turn on the Battery Isolators on the HP-6M and all connected HP-6S units.
The recommended sequence for turning on the Battery Isolators is HP-6M first,
followed by the adjacent HP-6S units.
3. Turn on the Main AC Isolator connected to the Energizer Homepower HP-6 Series system.
a. If applicable, turn on any AC Isolators.
4. Return the Magna-Flaps to their original position on HP-6M (& all connected HP-6S) units.
5. If Backup/UPS loads are connected, turn on respective AC Isolators.
a. Turn on any AC Isolators if applicable.
6. The system shall turn ON and resume normal operation now.
DANGER! Please do not attempt to disassemble the HP-6M or HP-6S in any way, as it
may cause damage to the product. Unsolicited disassembly shall void any applicable
manufacturer (or performance) Warranty.

Step 4 - Technical Resolutions

If the system fault remains, first attempt to connect your system to the internet and ensure you have all relevant
information pertaining to the fault, such as system serial number, contact information and a general description
of the issue prior to contacting your system provider.
V23-00211
6
Series
Wait at least five minutes for the system to completely de-energize.
21