8 Operating Limits

Figure 2-8.1: Operating limits
Coolinging operation
°
12 17
Indoor temperature(
Table 2-8.1: Operating limits
Cooling operation
Heating operating
Dehumidification operating
Notes:
1. If the unit is running outside the above condition, protective device will start, and even then the units take place abnormality running.
2. These figures base on the operation conditions between indoor units and outdoor units: Equivalent pipe length is 5m, and height difference is 0m.
Precaution:
1. The indoor relative humidity should be lower than 80%. If the air conditioner works in an environment with a relative humidity higher than mentioned above,
the surface of the air conditioner may condensate. In this case, it is recommended to set the air speed of the indoor unit to high.
22 27 32 37
C WB
)
°
Mode
Outdoor temperature
-5ºC〜55ºC
-15ºC〜27ºC
-5ºC〜55ºC
Room temperature
17ºC〜32ºC
0ºC〜30ºC
12ºC〜32ºC
65