REPLACE METER
1. Disconnect the meter cable from the
meter. (If ow meter cable is attached)
C o u p l i n g
Adapter
3. Remove the coupling adapter from
the bypass.
CLEAN INJECTOR ASSEMBLY
2×Screws
O-ring on Cap
Injector Cap
1. Remove the two screws of the injector cap.
2. Pull the injector cap out, watch for the o-ring on the cap.
3. Screw the injector assembly out, clean/replace it.
4. Pull the screen out, clean/replace it.
5. After servcing, reverse following steps in this section.
2. Disconnect the bypass from valve by removing clips.
Meter
Support
4. Remove the meter support from the
bypass.
Injectors
Screen
2 X Screws
2 X Clips
Meter Ball
Meter
5. Remove the meter and replace it.