Table of Contents Please Observe the Following ....................3 Emphasized Sections ......................3 For Your Safety ........................3 Unpacking and Inspection ....................5 Packing List ........................... 5 Features ..........................5 Usage ............................. 5 Description ........................... 6 2.1 Theory of Operation ........................6 2.2 Display, operating elements and connections ..............
Declaration of Conformity ......................19 Please Observe the Following Emphasized Sections Warning! Refers to safety regulations and required safety measures that protect the operator or other persons from injury or danger to life. Caution! Emphasizes what must be done or avoided so that the unit or other property is not damaged.
Page 4
WARNING! It is the responsibility of the user to ensure that all devices are set-up in a safe manner. The manufacturer is in no way responsible for injuries or damage to persons or property resulting from the device. For safe and successful operation of the unit, read these instructions completely. If the instructions are not observed, the manufacturer can assume no responsibility.
Footswitch x 1 1.4.5 Footswitch Adapter x 1 Features 1.5.1 Capacity for up to four UV LED Heads. 1.5.2 Works with Loctite EQ CL40 Spot Heads. 1.5.3 Touch screen HMI 1.5.4 3 running modes: Timer, Continue and Advance. 1.5.5 User friendly interface...
Description 2.1 Theory of Operation The EQ Controller provides electrical power to the LED’s through the connecting cable. Indicator lights located on the front panel of the power supply provide visual confirmation that the LED’s are in or out of their acceptable range. In the event of temperature fault the power supply will automatically shut down to protect the LED array.
Technical Data Dimensions (W x H x D): 99x162x163 mm Total weight: Kg (lbs.) 2 (4.4) Operating voltage: 24V DC (60W Adapter) Power consumption: <35 Watts Operating Temperature: +10 °C to +40 °C (+50 °F to +104 °F) Storage Temperature: - 10 °C to +60 °C (+14 °F to +140 °F)
Installation Before using the equipment for the first time check it carefully for signs of external damage. If any shipping damage is found DO NOT USE THE EQUIPMENT – return it to your supplier immediately. 4.1 Environmental and Operating Conditions No direct sunlight.
5.3 Main Page Channel Manual Switch Channel LED head running Mode: CONTINUE, TIMER, ADVANCE Intensity percentage Time (Exposure time) Temperature (To display LED head temperature - For indication only) To Main page To Parameter Setting page To Warning Message page...
5.4 Parameter Setting Page 1. Operating Mode selection: Continue, Timer or Advance Continue Mode: The LED head will turn ON when a footswitch is pressed and remain ON until the footswitch is released. The intensity can be set up for each channel independently. : The LED head will turn ON when a footswitch is pressed and remain ON for the Timer Mode duration that is set on the timer.
Page 12
3. Restore factory setting. 4. Save Setting: Save changes. 5. Intensity & Timer setting. When clicked, can enter below page to set intensity and timer. Continue Mode: Enter required intensity percentage setting (normal operation set 100%). Continue Timer Mode: Enter required intensity percentage setting (normal operation set 100%) and curing time required.
Page 13
Advance Mode: This enables intensity to change automatically during the curing cycle For example, if operator have defined as below, when start signal comes, LED head will work step by step. Time and power will follow each step’s setting to run 2 cycles.
5.5 Warning Message Page Connection error Overheat error(Alarm temperature threshold 65 C) Clear the warnings Application Hints As with all adhesives, performance depends on conditions of use. Suggestions or recommendations contained herein are for guidance only since actual conditions of use are outside the supplier’s control.
Page 15
Malfunction Cause/Demonstration Corrective Action Check that the main power Plug in power cable No display appears on the cable is connected to an AC properly. screen when turning on source. power supply Check the fuse in power Replace fuse. inlet. Check if selecting the target Select the target channel channel for the program.
The linked LED head does Check if linked button was Resolve the problem, and not turn on with start signal selected. then restart irradiation Care and Maintenance The unit requires no special care and maintenance. Observe the operating manual of the LED head used. Accessories and Spare Parts Item Description IDH#...
Henkel, the use of products, parts or attachments which are not manufactured by Henkel, no claim shall be allowed. No Products shall be returned to Henkel for any reason without prior written approval from Henkel. Products shall be returned freight prepaid, in accordance with instructions from Henkel.
Page 19
THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS. WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR...
Need help?
Do you have a question about the Loctite EQ CL40 and is the answer not in the manual?
Questions and answers