Overpressure (without degrading performance)
Temperature effects over compensated range (zero-span)
Output short circuit and reverse polarity protection
(*) Other voltage values of Zero and Full Scale available on request.
NOTE: SIL2 certification is available from 0-4 bar range and above
FS = Full Scale Output
1 Incl. Non-Linearity, Hysteresis, Repeatability, Zero-offset and Final-offset (acc. to IEC 61298-2)
2 The operating pressure range is intended from 0.5% to 100% FS
3 Time within which the rated performance is achieved
Range (bar)
1
1.6
Overpressure
6
6
(Bar)
Burst pressure
9
9
(Bar)
85194D_MAN_Electrical Installation for Probes_KS and KS-SIL2 Series_11-2021_ENG

4. Technical specifications

Output signal
Accuracy (1)
Pressure ranges (2)
Resolution
Pressure containment (burst test)
Pressure Media
Power supply
Dielectric strengh
Zero output signal
Full scale output signal
Max allowed load
Long term stability
Operating temperature range (process)
Operating temperature range (ambient)
Compensated temperature range
Storage temperature range
Response time (10...90%FS)
Warm-up time (3)
Mounting position effects
Mechanical shock
Vibrations
Protections
CE Conformity
Electromagnetic compatibility Emission
2
2.5
4
6
10
6
10
10
20
20
9
15
15
30
40
Voltage
from 1 bar to 1000 bar (see table)
Fluids compatible with Stainless Steel AISI 430F and 17-4 PH
Housing
15...30Vdc
0.1V; 0.5V; 1V (*)
5V; 5.5V; 10V; 10.1V; 10.5V (*)
2 mA
± 0.015% FS/°C typical (± 0.02% FS/°C max.)
Humidity
Up to 100%RH non-condensing
Weight
100g/11msec according to IEC 60068-2-27
20g max a 10...2000 Hz according to IEC 60068-2-6
IP65/IP67 (M12 version) with female homologated connector
mounted, tightening torque 0.6Nm + low strenght threadlocker
Lifetime
16
20
25
40
60
32
40
50
80
120
64
80
100
160
240
Current
< ±0.5% FS
Infinite
see table below
see table below
Stainless Steel AISI 304
10...30Vdc
250 Vdc
4 mA (nominal)
20 mA (nominal)
see load diagram
< 0.2% FS/per year
-40...+125°C (-40...+257°F)
-40...+105°C (-40...+221°F)
-20...+85°C (-4...+185°F)
-40...+125°C (-40...+257°F)
< 1 msec.
< 30 sec.
Negligible
80-120 gr. nominal
YES
EC Directive 2004/108/CE
EN61326-1/EN61326-2-3
10 years
100
160
200
250
400
200
320
400
500
800
400
640
800
1000
1500
600
1000
1200
1200
1500
1500