Faraday 15220A Owner's Manual page 17

System control unit
Table of Contents

Advertisement

Step 2.)
B.) Use four #10 lag screws (not supplied) to
secure the control unit to the wall.
NOTE: The screw type may be required to be
different depending on the wall
material.
The screw type and length must
support up to 35 lbs.
(control unit, options and battery set).
C.) If the control unit is to be mounted
semi-flush, the backbox can be mounted
up to 3.5" into the wall.
Place the 15216 Semi-flush Trim around
the backbox and affix to the wall with four
#10 x 3/4" wood screws (P/N 940454).
NOTE: The screw type may be required to be
different depending on the wall
material.
Step 3.)
1.)
2.)
3.)
SIDE OPTION
15209
15215
(Local Energy)
15215
(Remote Station)
15217
15206
III- 2
firealarmresources.com
Attach conduit (if required) and run wires as
required. Do not connect wires at this time.
Non power limited field wires must be run in
separate conduit and be 1/4" from power
limited wires.
120VAC power use knock out "A".
Main panel and top mount options use
knock out "B".
Side mount option wiring use knock out "C"
(see chart).
NOTES
All field wiring must be power limited to
module
All field wiring must be non power limited to
module
All field wiring must be power limited to
module
Wiring may be either all power limited or all
non power limited. The 2 types cannot be
mixed together.
All field wiring must be power limited to
module