Olympus IPLEX GAir IV9000GA Instructions Manual

Olympus IPLEX GAir IV9000GA Instructions Manual

Industrial endoscope
Table of Contents

Advertisement

Quick Links

INSTRUCTIONS
IPLEX GAir
INDUSTRIAL ENDOSCOPE
IV9000GA
IV98200GA
IV98300GA
Industrial Endoscope
MM3868 04
Issued in September, 2021

Advertisement

Table of Contents
loading

Summary of Contents for Olympus IPLEX GAir IV9000GA

  • Page 1 INSTRUCTIONS IPLEX GAir INDUSTRIAL ENDOSCOPE IV9000GA IV98200GA IV98300GA Industrial Endoscope MM3868 04 Issued in September, 2021...
  • Page 3: Table Of Contents

    Contents Introduction Intended use Instruction manual Product configuration Safety precautions Safety precautions - General safety precautions - Safety precautions - Battery precautions - Safety precautions - External battery precautions - Safety precautions - Illumination light precautions - Rating plate / Caution plate 1.
  • Page 4 3.7 Attaching and removing the guide head 3.8 Connecting and disconnecting the USB wireless LAN adapter 3.9 Attaching and removing the pole unit 3.10 Attaching and removing the push rod adapter 3.11 Attaching and removing the centering device 3.12 Pre-operation / Post-operation inspections 4.
  • Page 5 4.11 Displaying live images on the external monitor 4.12 Displaying live images on the mobile terminal 4.12.1 Connecting the USB wireless LAN adapter 4.12.2 Enabling the USB wireless LAN adapter from the menu 4.13 Using recorded images on a PC 4.14 Displaying the gravity direction 4.15 Rotating the live images automatically 4.16 Displaying the insertion length...
  • Page 6 9. Storage and maintenance 9.1 Replacing the battery or the external battery 9.2 Replacing the O-ring 9.3 Cleaning components 9.3.1 Cleaning the insertion tube 9.3.2 Cleaning the distal end 9.3.3 Cleaning the optical adapter 9.3.4 Cleaning the LCD monitor 9.3.5 Cleaning the centering device or the guide head 9.3.6 Cleaning other units 9.4 Removing water from the drain 9.5 Replacing the fuse...
  • Page 7: Introduction

    If you have any questions about any information in this instruction manual, please contact Olympus. The symbols used in the texts of this manual have following meanings: [ ] indicates the words on the user interface of the product displayed in English.
  • Page 8: Safety Precautions

    Safety precautions Note that use of this instrument in ways that are not specifically described in this instruction manual does not ensure the safety and it may also cause the malfunction of this instrument. Be sure to follow this instruction manual when using this instrument. The following symbols are used throughout this instruction manual.
  • Page 9 Olympus is not liable for any accidents or instrument damage that occurs as a result of repairs attempted by personnel who are not authorized by Olympus. Stop using the instrument immediately at the first sign of heat, smoke, abnormal odor, abnormal noise or any other abnormality.
  • Page 10 Do not use commercially-available electronic transformers for overseas travel use (travel converters). Use only the power cord and the AC adapter specified by Olympus and connect the power cord to the power outlet within the rated range. Otherwise, smoke, fire, or electric shock may occur.
  • Page 11 Never use the optical adapter if any of its parts are loose. Otherwise, the loose parts may fall off. If the optical adapter cannot be attached or removed because the nut does not rotate, stop using it. Contact Olympus.
  • Page 12 CAUTION: If abnormality is found in the observation image, stop using immediately and pull out the insertion tube from the inspection object carefully. If the optical adapter is about to fall off from the distal end of the insertion tube while inserting the insertion tube into the inspection object, the illumination turns OFF.
  • Page 13 IPLEX GAir CAUTION: Do not subject the LCD monitor to strong impact, strong pressure or to scratching by a hard or pointed object. Otherwise, the LCD monitor may be cracked or scratched, or the damaged monitor may cause personal injury. When pushing down the handle, be careful not to get your hand or other objects caught in between.
  • Page 14 NOTE: Do not store the instrument in the following locations. Environments exposed to high temperature, high humidity and large amounts of dust or particulate Locations exposed to direct sunlight or radiation Locations exposed to gas containing halide Otherwise, the instrument may be damaged. *1 The performance of some electrical parts may deteriorate due to the halide in insecticides, pesticides and gaseous extinguishing agents, etc.
  • Page 15 IPLEX GAir NOTE: Be careful not to allow scattered water droplets to come in contact with the terminals. Be careful not to allow scattered water droplets to come in contact with each terminal of the AC adapter, relay cable, drum unit, scope unit or base unit. Otherwise, the instrument may be damaged.
  • Page 16: Safety Precautions - Battery Precautions

    Safety precautions - Battery precautions - If you experience any problems when using this instrument with batteries, contact Olympus. Comply strictly with the precautions described below when handling the battery. If the batteries are handled improperly, the battery fluid leakage, excessive heat generation, smoke, battery burst, electric shock and/or burns may result.
  • Page 17 Do not allow metal or water, or any other fluid to get into the battery compartment or onto the battery terminals. If any foreign object enters the drum unit, remove the battery and disconnect the AC adapter, and immediately contact Olympus. Do not remove the battery immediately if the instrument was used continuously for a long time.
  • Page 18 If you are experiencing problems removing the battery from the drum unit, do not attempt to remove it forcibly. Contact Olympus. Contact the airlines in advance if you plan to transport the battery by aircraft. When replacing the battery, do not repeat inserting or removing it rapidly.
  • Page 19: Safety Precautions - External Battery Precautions

    MH battery to be attached to the external battery case is called “External battery”. DANGER: Use the external battery case MAJ-2485. Use the external battery recommend by Olympus described below. Single shape NiMH battery complied with IEC62133-1 Temperature range: Sufficiently wider than the temperature range of external battery case (0 °C to 48 °C) is recommended.
  • Page 20 If any foreign object enters the external battery case, remove the external battery and disconnect the AC adapter, and immediately contact Olympus. Do not remove the external battery immediately if the instrument was used continuously for a long time.
  • Page 21 If you are experiencing problems removing the external battery from the external battery case, do not attempt to remove it forcibly. Contact Olympus. When replacing the external battery, do not repeat inserting or removing it rapidly. Otherwise, the power may not be turned ON.
  • Page 22: Safety Precautions - Illumination Light Precautions

    CAUTION: Note the following when replacing the fuse of the external battery case. Do not touch the fuse with your wet hands. Remove the external battery case from the drum unit carefully. Remove the external battery from the external battery case carefully. Use the specified fuse.
  • Page 23 IPLEX GAir CAUTION: Turn OFF the illumination if not necessary. If the illumination light enters your eyes, your eyes may get injured. If you see the illumination light for a long time even though it is at the edge of your field of view, your eyes may get injured. If there is any possibility that the illumination light enters human eyes, turn OFF the illumination if not necessary.
  • Page 24: Rating Plate / Caution Plate

    Study the meaning of the safety symbols and always use the product in the safest possible manner. If labels are missing or if their contents are illegible, contact Olympus. Conformity label, rating, model, serial number DO NOT USE CAUTION: Do not peel off the sticker showing "DO NOT USE".
  • Page 25 IPLEX GAir Conformity label, model, serial number, precautions CAUTION: Be careful for the possibly hazardous optical radiation emitted from this product. (See page 16) Pay careful attention to the temperature of the distal end of the insertion tube immediately after using this instrument in warm temperature environments.
  • Page 26 Conformity label, model, precautions CAUTION: When using the external battery, follow cautions described in instruction manual. (See page 13) Information of fuse CAUTION: Be sure to use the specified fuse. Otherwise, a fire may be caused. (See page 135) Information of insertion direction of external battery CAUTION: Do not insert the external battery in the external battery case with wrong polarity (+ or -).
  • Page 27: Unpacking

    IPLEX GAir Unpacking 1.1 Unpacking When unpacking, make sure that all items listed below are included. If anything is missing or damaged, contact Olympus. Name Quantity Base unit Drum unit SDHC card (4 GB, inserted into the SDHC card slot of the base unit)
  • Page 28: Options

    Storing the optical adapter case The optical adapter case can be stored in the optical adapter case holder on the drum unit. 1.1.2 Options Scope unit IV9●●●GA ((●●●) indicates the scope diameter and the length.) Name Quantity Scope unit Tip cap Spool Lens cleaning kit (cotton swab, brush) O-ring...
  • Page 29: Nomenclature

    IPLEX GAir Nomenclature 2.1 Nomenclature Base unit Name Handle Hook for attaching the remote control unit Interface door LCD monitor [POWER] button ( ) [LIGHT] button ( ) DC-IN terminal USB connector HDMI terminal 10 Headset terminal 11 SDHC card slot 12 microSDHC card slot 13 SD card door 14 Relay cable door...
  • Page 30 Drum unit Name Drum rotator Optical adapter holder Drum rotation handle Handle Main switch DC-IN terminal Battery door Lock belt Ext-Batt.-IN terminal 10 Drain Scope unit Name 1 Scope unit main body 2 Insertion tube 3 Angulation section 4 Distal end 5 Tip cap...
  • Page 31 IPLEX GAir Relay cable or 5 m relay cable Name 1 Branch 2 Connector (for drum unit) 3 Connector (for base unit) 4 Connector for power supply 5 Fixture Remote control unit Name Name 1 [ZOOM] lever [MEAS/ENTER] joystick 2 [BRIGHT] lever [LIVE] button 3 [ANGLE/SPEED] joystick 10 [CENT] button...
  • Page 32: Distal End / Optical Adapter Nomenclature

    External battery case Name 1 External battery case main body 2 Strap 3 Connector 4 Latch 2.2 Distal end / Optical adapter nomenclature Name Distal end Optical adapter positioning groove First screw thread Second screw thread Connecting screw thread Objective lens Optical adapter O-ring Illumination...
  • Page 33: Lcd Monitor Nomenclature

    IPLEX GAir 2.3 LCD monitor nomenclature Live screen Freeze screen Icon/ Name Indicator Folder name Optical adapter name Distal end temperature indicator Insertion length information Gravity direction icon Zoom level Brightness level Date/Time Grid SD card icon Number of images that can be recorded External battery indicator Battery indicator Freeze icon...
  • Page 34 Icon/ Name Indicator Wireless LAN icon Image rotation stop icon Angle centering icon LED icon Gain mode icon Title Logo *1 This is displayed for three seconds when the SDHC card is inserted or when the number of recordable images changes. TIP: The title input on the live screen last time the systems was used is displayed.
  • Page 35 IPLEX GAir Button name Function FOLDER Shows or hides the [MEAS/ENTER] button (No.6) [ZOOM] Shows or hides the zoom level buttons (T, W) [BRT] Shows or hides the brightness level buttons (+, -) Switches between the live image and frozen image [FRZ]/[STOP] Stops recording when recording the movie [REC]...
  • Page 36 Thumbnail screen Icon/ Name Indicator Folder name File name Distal end temperature indicator Note icon Optical adapter name Movie icon Zoom level Brightness level Date/Time SD card icon Remaining space on SD card External battery indicator Battery indicator Angulation speed icon Wireless LAN icon Image rotation stop icon Check-mark icon...
  • Page 37 IPLEX GAir Icon/ Name Indicator Gain mode icon Title Logo LED icon Thumbnail screen (touch panel buttons) No. Button name Function 1 Previous page Jumps to the previous page Next page Jumps to the next page Check-mark Switches the check-mark assignment mode of the thumbnail images [ON] Check-mark Selects or deselects all the check-marks of the thumbnail images...
  • Page 38 Icon/ Name Indicator Folder name File name Distal end temperature indicator Optical adapter name Zoom level Brightness level Date/Time Grid SD card icon Number of recordable images External battery indicator Battery indicator Angulation speed icon Wireless LAN icon Image rotation stop icon LED icon Gain mode icon Title...
  • Page 39 IPLEX GAir ●When playing back the movie Icon/ Name Indicator Movie playback time Movie playback position bar Index mark Total movie duration Play movie icon Pause movie icon End movie playback icon View screen (touch panel buttons) ●When playing back the still image Button name Function Display Previous...
  • Page 40 Button name Function Image ●When playing back the movie No. Button name Function Backward Jumps to previous index mark when playing back the movie 6 Fast Reverse Fast reverse when playing back the movie 7 Fast Forward Fast forward when playing back the movie Forward Jumps to next index mark when playing back the movie Play movie...
  • Page 41 IPLEX GAir ●Playing back using the touch panel and [MEAS/ENTER] joystick No. Button name Function ERASE Erases a constant video COPY Copies a constant video on an SDHC card 3 Fast Reverse Fast reverse when playing back the movie 4 Fast Forward Fast forward when playing back the movie *For procedures to play back the movie using the joystick, see "Playing back and pausing the movie"...
  • Page 42 ●Operating using the touch panel and [MEAS/ENTER] joystick No. Button name Function RETURN Returns to the menu of the view screen COLOR Selects the line color LINE Selects the line width Records the image with note information CLOSE Closes the note display screen and returns to the previous screen [CURSOR/OK Shows, moves or hides the [CURSOR/OK] button TEXT...
  • Page 43: Pre-Operation Preparation And Inspection

    IPLEX GAir Pre-operation preparation and inspection Be sure to perform the preparation and inspection described in this chapter before using the instrument. At the first sign of any abnormality, immediately stop using the instrument and perform the required actions as described in "Troubleshooting" (page 124). Inspections are not only required before use but also should be conducted periodically.
  • Page 44: Preparing The Product

    Make sure that the latch (A) of the case is completely closed. Press the PUSH button (B) to unlock the extendable handle (C), and then extend it. To store the extendable handle, press the PUSH button to push down the extendable handle.
  • Page 45 IPLEX GAir Remove the following units. Instruction manual External battery case 5 m relay cable, battery charger, AC adapter, AC power cord and HDMI cable...
  • Page 46: Removing The Scope Unit From The Scope Case

    Hold the handle of the drum unit, and remove the drum unit and the base unit from the carrying case. 3.2.2 Removing the scope unit from the scope case Hold the scope unit main body (A) and the spool (B), and remove them from the case. 3.2.3 Attaching the scope unit NOTE: Turn OFF the power of the drum unit before connecting or disconnecting the scope unit.
  • Page 47 IPLEX GAir Make sure that no foreign objects such as dirt or dust, etc. are attached to the terminals of the drum unit and the scope unit. NOTE: Check that there is no scratch or damage on the O-rings (4 positions) (A) of the terminal on the scope unit side.
  • Page 48: Attaching And Removing The Relay Cable

    Tighten the clamping screws (2 positions) of the scope unit using the coin, etc., and secure it to the drum unit. NOTE: Make sure that the clamping screws (2 positions) of the scope unit are tightened completely. Rotate the drum rotation handle (C) of the drum unit and wind the insertion tube (D) of the scope unit around the drum rotator.
  • Page 49 IPLEX GAir NOTE: Be sure to turn OFF the power before connecting or disconnecting the relay cable. Attaching the relay cable Slide the fixing lever of the handle at the upper area of the drum unit horizontally, open the handle cover, and remove the base unit from the drum unit. Put the relay cable through the cable holder (A) of the base unit.
  • Page 50 Open the relay cable door (E) of the base unit, and connect the relay cable (F). Route the cable so that it is not subject to excess force or twist, and close the relay cable door (E) while paying attention not to allow the cable to be caught. When using the 5 m relay cable, push the cable in the dent and close the relay cable door (E).
  • Page 51: Attaching And Removing The Base Unit

    IPLEX GAir Open the relay cable door (H) of the drum unit, and connect the relay cable. Push the cable in the cable fixing part (I) of the drum unit, and close the relay cable door (H). NOTE: Close the relay cable door securely. Removing the relay cable Remove the relay cable in the reverse order of the attaching procedures.
  • Page 52 When attaching the base unit to the drum unit, attach the base unit to the handle of the drum unit. TIP: The example of attaching the base unit is illustrated below. The screen of the LCD monitor must be For procedures to use the pole unit, see rotated 180 degrees.
  • Page 53 IPLEX GAir Using the base unit without attaching to the drum unit The base unit can be placed on a flat surface, hung from a height, or attached to a tripod for operation and observation. Placing the base unit on a flat surface When performing the observation by placing the base unit on a flat surface, use the handle as a stand.
  • Page 54: Preparing The Power Supply

    CAUTION: Be sure to attach the base unit to the tripod securely to prevent it from falling off, which may cause injury or damage to the unit as a result. 3.3 Preparing the power supply 3.3.1 Using the battery Checking the remaining battery level (on battery alone) The remaining battery level can be checked on the [POWER INDICATOR] of the battery.
  • Page 55 IPLEX GAir Slide the release knob of the battery door of the drum unit to open the door. Insert the battery paying attention to the orientation of the battery. Make sure that the battery is locked, and close the door. Make sure that the battery door is locked.
  • Page 56: Using The External Battery

    Removing the battery Remove the battery by moving the tab (A) at the battery insertion slot in the arrow direction. 3.3.2 Using the external battery Follow the procedures below to connect the external battery...
  • Page 57 IPLEX GAir Insert the eight external batteries straight in the external battery case paying attention to the orientation of the external batteries, and close the latch (A) of the case. NOTE: Do not insert the external battery in the external battery case with wrong polarity (+ or If you insert the external battery diagonally, it is caught in the middle as shown in the picture below and it cannot be inserted completely.
  • Page 58 Attach the case connector to the Ext-Batt.-IN terminal on the drum unit. TIP: Be sure to recharge the external battery before using it for the first time after purchase or after it has not been used for a long period. In general, the external battery performance is degraded temporarily as the ambient temperature drops.
  • Page 59: Using The Ac Adapter

    IPLEX GAir 3.3.3 Using the AC adapter Follow the procedures below to connect the AC adapter. Open the DC-IN terminal cap (A) on the drum unit. Connect the connector (B) for power supply of the AC adapter to the DC-IN terminal of the drum unit.
  • Page 60: Attaching And Removing The Optical Adapter

    3.4 Attaching and removing the optical adapter NOTE: Be sure to attach the O-ring to the distal end of the insertion tube before using the optical adapter. Water or dirt that enters the unit from the connecting area between the insertion tube and the optical adapter may cause malfunction or damage to the unit.
  • Page 61 IPLEX GAir Attaching the optical adapter Holding the optical adapter and the distal end so that they make one straight line with each other, carefully insert the optical adapter into the distal end. Rotate the nut (G) of the optical adapter (H) clockwise until the connecting screw thread passes the first screw thread.
  • Page 62: Inserting And Removing The Sdhc Card Or The Microsdhc Card

    3.5 Inserting and removing the SDHC card or the microSDHC card Inserting the SDHC card or the microSDHC card Open the SD card door. While paying attention to the orientation of the SDHC card or the microSDHC card, insert it to the end until a “click” sound is heard. Then, close the SD card door. SDHC card microSDHC card Removing the SDHC card or the microSDHC card...
  • Page 63: Attaching And Removing The Remote Control Unit

    IPLEX GAir 3.6 Attaching and removing the remote control unit Open the interface door (A). Connect the remote control unit to the USB connector (B). TIP: Hanging the hanger for attaching the base unit (C) of the remote control unit over the hook (D) for attaching the remote control unit of the base unit allows you to attach the remote control unit to the base unit.
  • Page 64 TIP: You can attach the guide head when using the forward-view optical adapter. There are two types of guide head: One for optical adapter 120D and the other for optical adapter 220D. The guide head for optical adapter 120D has a positioning hole (A). For 120D For 220D Attaching the guide head (when using the optical adapter 120D)
  • Page 65 IPLEX GAir Insert the cap (D) into the distal end and rotate it to attach to the base. If it is difficult to rotate the cap (D), there is a possibility that the position of the hole (E) of the guide head is not aligned with the position of the D cut (F) of the distal end. Align the positions again and rotate the cap (D).
  • Page 66: Connecting And Disconnecting The Usb Wireless Lan Adapter

    3.8 Connecting and disconnecting the USB wireless LAN adapter Connecting the USB wireless LAN adapter Open the interface door. Attach the USB wireless LAN adapter (recommended) to the USB connector. For the recommended USB wireless LAN adapter, please contact Olympus.
  • Page 67: Attaching And Removing The Pole Unit

    IPLEX GAir TIP: One USB connector is equipped with the base unit. Connecting the USB hub (commercially- available) allows you to use the remote control unit and the USB wireless LAN adapter at the same time. Use the commercially-available USB hub that supports USB 2.0. Removing the USB wireless LAN adapter To remove the USB wireless LAN adapter, follow the steps for attaching the USB wireless LAN adapter in the reverse order.
  • Page 68 Insert the pole unit so that the attaching pins (B) of the base of the pole unit align with the pole mounting holes (A) of the handle cover, and tighten the fixing knob (C). Insert the pole unit so that the fixing knob (C) is positioned as shown in the picture below. If the pole unit is attached in wrong orientation, you cannot tighten the fixing knob.
  • Page 69: Attaching And Removing The Push Rod Adapter

    IPLEX GAir 3.10 Attaching and removing the push rod adapter Rotate the cap to remove it from the push rod adapter. Put the insertion tube through the push rod adapter. CAUTION: Attach the push rod adapter at the position approximately 2 m away from the distal end of the insertion tube.
  • Page 70 NOTE: The centering device is a consumable item. It will wear out after repeated use. The centering device may come into contact with surroundings during use, which may cause wear powder to fall inside the pipe. Do not use the centering device if the wear powder causes problems for inspection objects.
  • Page 71 IPLEX GAir Insert the parts assembled in the Step 2 into the insertion tube (F) as shown below, and move it to the position just passing the fixing groove (H) of the angulation section (G). Insert the other plate (B) into the insertion tube, and position it in contact with the parts assembled in the Step 3.
  • Page 72 Insert the cap (D) into the insertion tube, and fit the surface (I) of the cap (D) with the fixing groove (H) at the base of the angulation section. The cap with O-ring (E) attached inside is the cap (D). TIP: When the surface (I) of the cap (D) is fitted with the fixing groove (H) at the base of the angulation section, the (J) part is engaged with the fixing groove (H) and the centering...
  • Page 73 IPLEX GAir Attach the parts assembled in the Step 5 to the cap (D). As the cap (D) is a 2-thread type screw, the screw is engaged twice. When the centering device is attached to the insertion tube securely, all are secured except plates.
  • Page 74: Pre-Operation / Post-Operation Inspections

    (page 131) tube or doors? □ Are there cracks or scratches on the LCD Replacement required. monitor, insertion tube or doors? Contact Olympus. □ Any irregularities such as damage to or deformation of the exterior materials, buttons, joysticks, or levers? □...
  • Page 75 IPLEX GAir Inspection location Item If abnormality is discovered positioning groove or screw threads of the distal end? □ Any distal end deformation or looseness, "Storage and maintenance" or unusual wear of connecting screw (page 131) thread? Never use the instrument while there is any looseness on the distal end.
  • Page 76 □ LCD monitor Any surface cracks or other abnormalities Replacement required. on the screen? Contact Olympus. TIP: The LCD monitor is manufactured based on precision technologies. The LCD monitor may contain pixels that do not light (visible as black dots) or light permanently (visible as bright dots).
  • Page 77 IPLEX GAir Inspection location Item If abnormality is discovered or broken. □ Guide head Are any parts loose? See "Attaching and removing the guide head" Never use the unit if any looseness is (page 57). found. Otherwise, the loose parts may fall off. □...
  • Page 78: Basic Operation

    Basic operation 4.1 Turning ON the power 4.1.1 Turning ON the power Turn ON the main switch of the drum unit. [POWER]LED on the drum unit turns ON in orange. Press the [POWER] button ( ) on the base unit for approx. 1.5 to 2 seconds. The power of the system turns ON, and [POWER]LED on the drum unit turns ON in blue.
  • Page 79: Selecting An Optical Adapter

    IPLEX GAir TIP: When the remote control unit is connected, buttons turn ON if the power of the system turns If the angulation speed icon ( ) is blinking when the power of this instrument turns ON, the compressor is being filled up with air. Please wait until the angulation speed icon turns ON.
  • Page 80: Checking The Remaining Battery Level And The Remaining External Battery Level

    Select the optical adapter to use, and press the [MEAS/ENTER] joystick. TIP: If the optical adapter is replaced during observation, reselect the new optical adapter on the menu screen. See "Menu operations" (page 104) and "Initial setting menu" (page 106). 4.2 Checking the remaining battery level and the remaining external battery level If the battery and/or the external battery (both or alone) is connected to this instrument, the...
  • Page 81: Turning On The Illumination

    IPLEX GAir TIP: The remaining battery level can also be checked on the [POWER INDICATOR] of the battery. (Note the remaining battery level shown on the LCD monitor is different from that shown on the battery indicator.) For details, see "Checking the remaining battery level (on battery alone)"...
  • Page 82 Turning ON/OFF the illumination manually Pressing the [LIGHT] button ( ) (A) turns ON or OFF the illumination. When the illumination turns ON, the LED icon ( ) is displayed on the LCD monitor. TIP: Long-pressing the [VIEW] button on the remote control unit allows you to switch the illumination in the order of turning ON (high beam), normal beam (eco) and turning OFF.
  • Page 83: Operating The Instrument

    IPLEX GAir 4.4 Operating the instrument This instrument can be operated using the buttons, levers and joysticks on the remote control unit as well as the touch panel on the base unit. Buttons, Levers Function Touch panel and Joysticks (A) [ZOOM] lever Uses the zoom function.
  • Page 84 Buttons, Levers Function Touch panel and Joysticks Adds the index marks while recording the movie. Displays the scaler measurement screen. Pressing this button while playing back the movie on the view screen will pause or resume playing back the movie. [MEAS/ENTER] Selects a menu.
  • Page 85 IPLEX GAir Buttons, Levers Function Touch panel and Joysticks On the thumbnail screen, operating this lever upward shows or hides the mark ( ) of the selected thumbnail image. Operating this lever downward shows or hides the mark ( ) of all thumbnail images. (H) [LENGTH] Shows the length setting dialog.
  • Page 86: Observing The Inspection Object

    Buttons, Levers Function Touch panel and Joysticks button + [CENT] button (press for 2 seconds or more at the same time) Switches the folder. Shows, moves or hides the [CURSOR/OK] button. TIP: If multiple functions are assigned to the button, the time to press the button distinguishes each function.
  • Page 87 IPLEX GAir NOTE: If the following message appears during inspection, immediately stop observation, carefully pull out the insertion tube, and perform the required action as instructed in "Error messages" (page 124). <HIGH TEMPERATURE (DISTAL END). PLEASE IMMEDIATELY PULL OUT THE INSERTION TUBE>...
  • Page 88 TIP: Keep the insertion tube as straight as possible until it reaches 2 m from the distal end to get the best angulation performance. When the ambient temperature of the distal end reaches approx. 88°C, the following message appears and the illumination changes from the high beam to the normal beam (eco). <ILLUMINATION MODE CHANGED TO ECO.>...
  • Page 89: Adjusting The Display Of The Live Image

    IPLEX GAir When the lock belt is secured When the lock belt is released 4.6 Adjusting the display of the live image 4.6.1 Still image (Freeze) While the live image is displayed, press the [FREEZE] button. The observed image is frozen and the freeze icon ( ) is displayed in the upper right corner of the LCD monitor.
  • Page 90: Switching The Folder On The Live Screen

    Operating the [BRIGHT] lever upward brightens the entire image and downward darkens the entire image respectively. Brightness can be adjusted to one of the 24 different levels. Switching the gain mode Pressing the [GAIN] button while a live image is displayed switches the gain mode. Mode Description Auto (No...
  • Page 91: Recording Images

    4.8 Recording images You can record the images being observed to a SDHC card as still images or movies. Use the provided SDHC card or the SDHC card recommended by Olympus. SD and SDXC cards cannot be used. Make sure that the SDHC card is correctly loaded before use.
  • Page 92 If the <FILE NAME MARK> menu is set to <ON>, you can add the letter “_A”, “_B”, “_C” or “_D” at the end of image file names. Use this function to categorize image files. The category names of the file marks can be changed. (Contact Olympus for details.)
  • Page 93: Recording The Still Image

    IPLEX GAir 4.8.2 Recording the still image Select the folder of the save destination. Operate the [MEAS/ENTER] joystick to select the folder of the save destination. (See "Switching the folder on the live screen" (page 84).) While the live image is displayed, short-press the [FREEZE] button. The image is frozen.
  • Page 94 Select the strings in the preset title list registered in advance. TIP: For procedures to register the preset title in advance, see "Registering a text string as a preset title" (page 114). The still image is recorded. The screen goes black for a moment and then the frozen image is displayed.
  • Page 95: Recording The Movie

    IPLEX GAir 4.8.3 Recording the movie Select the folder of the save destination. Operate the [MEAS/ENTER] joystick to select the destination folder for saving files. (See "Switching the folder on the live screen" (page 84).) While the live image is displayed, long-press the [RECORD] button. Confirm the folder name and select <YES>.
  • Page 96: Adding The Movie

    Select <YES>. The recording of the movie and the sound starts. While the movie recording is in progress, the recording movie icon ( ) on the LCD monitor blinks. If you select <NO> in the movie recording confirmation dialog, only the still image is recorded and the movie is not recorded.
  • Page 97: Playing Back An Image In A Full-Screen View (View Screen)

    IPLEX GAir The thumbnail screen shows multiple images in a list, which is useful when finding a particular image among a large group of images. Live screen or Freeze screen [THUMBNAIL] button [VIEW] button [LIVE] button [LIVE] button [THUMBNAIL] button [VIEW] button [THUMBNAIL] button Press [MEAS/ENTER] joystick...
  • Page 98: Displaying The Thumbnail Screen And Selecting The Played Back Image

    4.9.2 Displaying the thumbnail screen and selecting the played back image The thumbnail screen shows multiple recorded movies and still images in a list (up to nine images per screen). The thumbnail screen is useful when finding a particular image among a large group of images or when selecting multiple images to move and delete at a time.
  • Page 99 IPLEX GAir Press the [THUMBNAIL] button on the live screen, freeze screen or view screen. A multi-image view of recorded images is displayed (up to nine images per screen). The movie icon ( ) appears for the movie. The sound icon ( ) appears for the image containing the sound.
  • Page 100: Sound Attached To The Still Image

    Constant video is a feature that automatically records movies up to about 50 minutes while the live screen is displayed. The constant video can be recorded on a microSDHC card. Use the microSDHC card recommended by Olympus. microSD and microSDXC cards cannot be used. Make sure that the microSDHC card is correctly loaded before use.
  • Page 101: Recording A Constant Video

    IPLEX GAir Mount a microSDHC card. Select the menu - <RECORD MODE> - <CONSTANT VIDEO> and set to <ON>. A constant video recording icon is displayed. To record the sound while recording the constant video, select the menu - <RECORD MODE>...
  • Page 102: Displaying Live Images On The External Monitor

    (commercially-available) where IPLEX Image Share is installed. To use IPLEX Image Share, install the application from Apple’s App Store. For details, refer to the Olympus website. https://www.olympus-ims.com/en/service-and-support/downloads/ IPLEX Image Share comes with the following features.
  • Page 103: Enabling The Usb Wireless Lan Adapter From The Menu

    The images recorded with this instrument can be used on a PC using InHelp VIEWER. The recorded images are loaded directly on the PC from the SDHC card where those images area recorded. To use InHelp VIEWER, download it from the Olympus website (https://www.olympus- ims.com/en/service-and-support/downloads/). TIP: Data on microSDHC cards cannot be loaded directly by a PC.
  • Page 104: Rotating The Live Images Automatically

    The gravity direction icon expresses the surface that is cut vertically against the inserting direction of the distal end of the insertion tube. The brown area indicates the ground side (gravity direction) and the blue area indicates the sky side (direction opposite to gravity). The white circle in the icon indicates the center of the ground side (gravity direction) and the red circle indicates the center of the sky side (direction opposite to gravity).
  • Page 105: Displaying The Insertion Length

    IPLEX GAir TIP: The rotation mode of the live image can also be changed on the <IMAGE ORIENTATION> menu. The rotation mode of the live image can also be changed by long-pressing the [LENGTH] button on the remote control unit. In <AUTO-ORIENTATE>...
  • Page 106 The reference point and the passing points are set in the insertion length setting dialog. The insertion length setting dialog can be displayed by pressing the insertion length displayed on the live image. TIP: The insertion length setting dialog can also be displayed by pressing the [LENGTH] button on the remote control unit.
  • Page 107 IPLEX GAir Example 1 With the pipe as shown below, assume the case to start observation from the position A, set the elbows B and C as the passing points, and observe up to the position D. The insertion length information (in meter) for each position is shown below. 1.
  • Page 108 Example 2 With the same pipe used in Example 1, the displays when setting the passing points at elbows and clearing each passing point are shown below. Tapping <S2 DELETE> or <C2 DELETE> at the position D will delete the information of the passing point C that was set second.
  • Page 109: Detecting When Pulling Out The Bent Angulation Section

    IPLEX GAir 4.17 Detecting when pulling out the bent angulation section When the insertion tube is pulled out from the inspection object while the angulation section is bent, the message appears or the remote control unit vibrates. TIP: When the drum unit is rotated in the winding direction, it is detected that the insertion tube is pulled out while the angulation section is bent.
  • Page 110: Menu Operations And Functions

    Menu operations and functions 5.1 Menu operations This instrument can be operated using the buttons and joysticks on the remote control unit as well as the touch panel on the base unit. Operation using the buttons and joysticks on the remote control unit Press the [MENU] button.
  • Page 111 IPLEX GAir Press the [MEAS/ENTER] joystick to apply the settings and return to the screen before displaying the menu. Using the touch panel Press the [MENU] button on the LCD monitor. The menu screen is displayed. Press the menu button you want to run. Pressing the [RETURN] button ( ) during menu operations will return to the screen one screen before.
  • Page 112: Using The Live Screen Or Freeze Screen

    5.2 Using the live screen or freeze screen 5.2.1 Initial setting menu When you turn ON the power of this instrument, the live screen appears. Pressing the [MENU] button on the live screen or the freeze screen allows you to make the following settings.
  • Page 113 IPLEX GAir Main Item menu menu NOISE You can specify whether to enable or disable the dynamic REDUCTION> noise reduction. <OFF> : Disable <ON> : Enable This option cannot be used for the freeze screen. <IMAGE Rotates the live image in gravity direction. ORIENTATION>...
  • Page 114 Main Item menu menu image. <SIDE STRETCH LOW>: Softly corrects the distortion shrinked outward. <SIDE STRETCH HIGH>: Strongly corrects the distortion shrinked outward. This option cannot be used for the freeze screen. This option cannot be used if any optical adapter is not selected.
  • Page 115 IPLEX GAir Main Item menu menu TIP: Formatting the microSDHC card deletes all data. <MOVIE FRAME Select the frame rate for movie recording. RATE> <30 Frames/Sec> <60 Frames/Sec> <STILL AUDIO> Makes settings for sound recording. You can specify whether to record the sound while recording the still image or the movie.
  • Page 116 Main Item menu menu You can display the software version of the base unit, initial data version and the upgrade information of the system. <START UP> Saves the settings when the power was turned OFF. By saving the settings when the power was turned OFF, you can specify whether to automatically apply such settings or not when the power is turned ON next time.
  • Page 117 IPLEX GAir Main Item menu menu in the following cases. When the insertion tube is pulled out from the inspection object keeping the distal end of the insertion tube bent. (When <SCOPE PROTECTION> is set to <ON>.) TIP: When the drum unit is rotated in the winding direction, the remote control unit vibrates.
  • Page 118: Inputting A Title

    Main Item menu menu <EXECUTE>: Formats the wireless settings. <PLAY Plays back the constant video. CONSTANT Plays back the constant videos automatically if there are VIDEO> recorded constant videos. <SELECT Displays the optical adapter list. OPTICAL You can set the optical adapter that is connected to the ADAPTER>...
  • Page 119 IPLEX GAir Select the input mode. Select </*@> or <ÀÁÂ>. Select the text buttons you want. To delete texts To delete a single text, move the cursor to it and select <DELETE>. To delete all input texts, select <CLEAR>. To input a space Move the cursor to the location where you want to input the space, and select <SPACE>.
  • Page 120: Registering A Text String As A Preset Title

    5.2.3 Registering a text string as a preset title Registering the frequently used text strings as preset titles in advance allows you to recall them when you input the titles. You can register a maximum of 54 text strings for preset titles. Input the text string you want to register in the title field.
  • Page 121: Adjusting The Image Sharpness

    IPLEX GAir Select the line for registering the text string. The text string you input in the title field is registered as the preset title. Registering a preset title overwrites anything currently in the line you specify in the list. You can, therefore, delete a preset title by registering the title input field keeping it blank.
  • Page 122: Date And Time

    5.2.6 DATE and TIME Use the procedure below to specify date and time. <SYSTEM SETUP> - <DATE TIME> - D.M.Y, H:M, DATE FORMAT SETUP Be sure to set the correct date and time before use if you use the instrument for the first time. The date and time information is recorded together with the screen information on the still image and the movie.
  • Page 123 IPLEX GAir Menu Available settings You can delete the images selected on the thumbnail screen or images with the mark ( <MOVE FILE> Moves image files from one folder to another. You can move the recorded images to a different folder. The images currently selected on the thumbnail screen or images with the mark ) are moved.
  • Page 124 Menu Available settings <EXECUTE>: Delete the image. You can delete the image displayed on the view screen. <NOTE> Inputs the note information (text/mark/free drawing) to the desired position on the screen (view screen for still image only). You can input the note information (text/mark/free drawing) on the still image that is being played back.
  • Page 125: Measurement Functions

    IPLEX GAir Measurement functions 6.1 Scaler measurement function 6.1.1 Scaler measurement Scaler measurement measures the length of an object using the reference length value that is preset according to a known length inside the observation image. NOTE: Therefore, if the reference length is incorrect, the correct measurement accuracy cannot be obtained.
  • Page 126 TIP: Tapping the [CURSOR/OK ON ] button ( ) each time changes the [CURSOR/OK] button repetitively in the order of show, move and hide. The recommended measurement region is displayed with dotted line when the optical adapter 220D is used. When <OFF>...
  • Page 127: Using Scaler Measurement

    IPLEX GAir Menu Description You can select <mm> or <inch>. <CURSOR> Selects a cursor shape. You can select <EXIT Exits the scaler measurement. MEASUREMENT> 6.1.3 Using scaler measurement Start up Press the [MEAS/ENTER] joystick while the image to be measured is displayed. Specify the reference points Align the cursor with one end of the object which is displayed in the image and of which length is known, and press the [MEAS/ENTER] joystick, and then align the cursor with the...
  • Page 128: Remote Operation

    This instrument can be operated away from the base unit using the repeater (transmitter) and the repeater (receiver) (recommended products). For the recommended repeater (transmitter) and repeater (receiver), contact Olympus. 7.1 Configuration example 1 Connecting units as follows allows you to operate this instrument remotely using the remote control unit while looking at the external monitor.
  • Page 129 Connecting units as follows allows you to control the power of the drum unit in addition to the remote operation shown in Configuration example 1. (Special settings are required for this configuration. Contact Olympus for details.) Remote side Operation side...
  • Page 130: Troubleshooting

    Inspect the instrument as described in "Pre-operation preparation and inspection" (page 37). If there are any obvious malfunctions, do not use the instrument and contact Olympus for repairs. If a slightest irregularity is suspected, do not use the instrument and take the actions described in "Troubleshooting guide"...
  • Page 131 While recording the movie or the sound, it cannot be recorded on the SDHC card for some reason. →Record the movie or the sound again. Or use the SDHC card recommended by Olympus. <MEASUREMENT IS NOT AVAILABLE The scaler measurement started while displaying the ON ZOOMED IMAGE.>...
  • Page 132 Message Cause and recommended action temperature became too high. →Stop inspection temporarily, turn OFF the power of the system to allow this instrument to cool down, and turn ON the power again. <PLEASE CENTER THE DISTAL END BY The distal end of the insertion tube may be caught by PRESSING THE CENTER BUTTON.>...
  • Page 133: Common Problems

    IPLEX GAir Message Cause and recommended action the external battery became too hot. →Stop inspection temporarily, turn OFF the power of the system to allow this instrument to cool down, and turn ON the power again. <OVER CURRENT (COMPRESSOR The self-check function was activated to prompt MOTOR).
  • Page 134 Problem Cause and recommended action →Attach the optical adapter. (See "Attaching and removing the optical adapter" (page 54).) The optical adapter cannot be A foreign object is stuck to the screws. attached to the insertion →Wipe with a clean piece of gauze or a cotton swab. tube.
  • Page 135 IPLEX GAir Problem Cause and recommended action →Turn OFF the main switch of the drum unit. The image is not sharp. The objective lens of the distal end of the insertion tube or the optical adapter is dirty. →Wipe with a clean piece of gauze or a cotton swab. The optical adapter is not attached correctly.
  • Page 136: Requesting Repair Of This Product

    Be sure to attach the warranty agreement when returning the instrument for repairs. The repair will be charged if the warranty agreement is not attached. The freight fees are paid by the user even if repairs are done free of charge. Olympus will not repair an instrument contaminated by noxious substances.
  • Page 137: Storage And Maintenance

    Contact Olympus about changing the battery. For detail procedures to load and remove the battery, see "Using the battery" (page 48).
  • Page 138: Cleaning The Optical Adapter

    You could also use the brush to brush away dirt and water droplets. Best results may be obtained by using a commercially available absolute ethanol or isopropyl alcohol. Cotton swab Brush Dirt on the optical adapter positioning groove or screw threads of the distal end Use the brush provided with the cleaning kit to brush away built up dirt.
  • Page 139: Cleaning The Lcd Monitor

    IPLEX GAir NOTE: Do not clean the optical adapter under running water. Otherwise, the optical adapter may be damaged. 9.3.4 Cleaning the LCD monitor LCD monitor viewing problems due to fingerprints and dirt Wipe the LCD monitor with a soft cloth moistened with clean water. Then, lightly wipe it with a clean and dry cloth.
  • Page 140 NOTE: Remove water from the drain after the air is exhausted from the compressor sufficiently. Otherwise, water may be scattered. Turn OFF the power of the system and wait until the air is exhausted. Press <OK> to close the message and turn OFF the power of the system. Place the dry cloth under the drain.
  • Page 141: Replacing The Fuse

    IPLEX GAir 9.5 Replacing the fuse CAUTION: To prevent the electric shock, turn OFF the power of the product, remove the external battery case from the drum unit, remove the external battery from the case, and then replace the fuse. Be sure to use the specified fuse.
  • Page 142: Storing In The Case

    9.6 Storing in the case 9.6.1 Storing in the carrying case Turn OFF the power, and remove the battery, AC adapter and remote control unit. Wrap the insertion tube around the drum of the drum unit, and cover it with the lock belt.
  • Page 143 IPLEX GAir Hold the handle of the drum unit, and store the drum unit and the base unit in the carrying case by paying attention to the orientation. Store the following units in the carrying case. Instruction manual External battery case 5 m relay cable, battery charger, AC adapter, AC power cord and HDMI cable...
  • Page 144: Storing The Scope Unit In The Scope Case

    Store the following units in the top cover. Optical adapter case Remote control unit Guide head Push rod adapter Pole unit (pole, camera platform) Battery * The optical adapter case can be stored either in the carrying case or the drum unit. NOTE: Do not close the cover of the case if the insertion tube is still protruding from the lock belt.
  • Page 145 IPLEX GAir Insert the distal end of the insertion tube into the distal end holder (A) (loop of the rubber band) on the spool gently until it touches the end. NOTE: Do not insert the distal end of the insertion tube into the distal end holder with excess force.
  • Page 146 Hold the scope unit main body and the spool, and store them in the scope case. NOTE: Do not close the cover of the case if the insertion tube is still protruding from the case. Otherwise, the insertion tube may be damaged.
  • Page 147: Specifications

    IPLEX GAir Specifications 10.1 Operating environment Item Specifications Operating temperatures Insertion tube In air: -25 to 100 °C In water: 10 to 30 °C Parts other than In air: -15 to 48 °C (Battery-powered operation) insertion tube and :    0 to 40 °C (AC adapter-powered operation) external battery case External battery case In air:   0 to 48 °C...
  • Page 148: Storage Environment

    NOTE: Meeting the operating environment specifications does not constitute any guarantee against damage to or malfunction of this instrument. Use AC adapter indoor (normal temperature). 10.2 Storage environment Item Specifications Storing temperatures Battery -20 °C to 60 °C (Recommended: 20 °C) 10.3 Other specifications 10.3.1 Other specifications Item...
  • Page 149 IPLEX GAir Item Specifications Base unit Dimensions 241(W) x 190(H) x 70(D) mm (excluding protrusion) Weight 1.56 kg Scope unit Dimensions 246(W) x 79(H) x 119(D) mm (excluding insertion tube and protrusion) Weight (including LED IV98200GA: 3.1 kg unit) IV98300GA: 4.2 kg Remote control unit Dimensions 39(W) x 137(H) ×...
  • Page 150 Input voltage : 100 V to 240 V AC ± 10% Frequency : 50/60 Hz Output voltage: 16 V DC External battery For recommended products, contact Olympus. 51W (AC adapter-powered operation) Power consumption SDHC card (for still image and movie recording)
  • Page 151 Output signal format Outputs in the HDMI signal format Frame rate 60 fps Manufacturer OLYMPUS CORPORATION Shinjuku Monolith, 2-3-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo 163-0914, Japan TIP: The images recorded with this instrument can be played back on a computer, etc., but the images recorded with other image recording devices such as a digital camera or a personal computer cannot be played back with this instrument.
  • Page 152: External Application Standard

    10.3.2 External application standard This product conforms to the following. EMC Information This product is applied with the requirements of standard IEC/EN61326-1 concerning electromagnetic compatibility. Emission Class A, applied to industrial environment requirements. Immunity Applied to industrial environment requirements. Some interference may occur if this product is used in domestic location.
  • Page 153: Software License Information

    Electronic Equipment, this symbol indicates that the product must not be disposed of as unsorted municipal waste, but should be collected separately. Refer to your local Olympus distributor for return and/or collection systems available in your country. Chinese RoHS Directive This logo is the logos to be applied to electrical and electronic products sold in China based on “Management Methods for the...
  • Page 154: Using Open Source Software

    THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE OSS IS WITH YOU. SHOULD THE OSS PROVE DEFECTIVE, YOU ASSUME THE COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. http://www.olympus-ims.com/rvi-products/iplex-gair/oss-license/ You shall not inquire information relating to the source codes obtained in the above URL from Olympus.
  • Page 155 IPLEX GAir AT120D/NF AT120D/FF AT120S/NF AT120S/FF AT220D Name -IV98G -IV98G -IV98G -IV98G -IV98G Optical Field of view 120° 120° 120° 120° 220° system Direction of Forward Forward Side view Side view Forward view view view view Depth of field 4 to 190 25 to ∞...
  • Page 156: Appendix

    Appendix System chart SDHC card IPLEX Image Share microSDHC card (provided / (Download from (recommended) Headset recommended) App Store) HDMI cable (commercially- External available) monitor (commercially- available) Main unit Mobile terminal (commercially- available) Base unit USB wireless LAN adapter (recommended) Relay cable Optical adapter case (1.5 m)
  • Page 157 IPLEX GAir Pole unit 5 m relay cable (optional) (optional) MAJ-2483 MAJ-2487 Scope unit (optional) IV98200GA IV98300GA Tip cap Optical adapter Guide head Push rod adapter (optional) (optional) MAJ-2484 120D/NF-IV98GA Centering MAJ-2486 120D/FF-IV98GA device Push rod 120S/NF-IV98GA (optional) (commercially- 120S/FF-IV98GA available) MAJ-1935 220D-IV98GA...

This manual is also suitable for:

Iplex gair iv98200gaIplex gair iv98300ga

Table of Contents