Operation Manual
Battery Charger
PB-6207B
* Rack mount products in the Western Hemisphere(North America, South America,
and the Caribbean) do not have handles installed due to customer preference.

Advertisement

Table of Contents
loading

Summary of Contents for Inter-m PB-6207B

  • Page 1 Operation Manual Battery Charger PB-6207B * Rack mount products in the Western Hemisphere(North America, South America, and the Caribbean) do not have handles installed due to customer preference.
  • Page 2 A personal welcome to you from the management and employees of Inter-M All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.
  • Page 3: Table Of Contents

    Operating Method ......................3 Equipment Setting and Checking .................4 Front Panel ........................5 Rear Panel ........................7 Equipment Setting and Checking details ..............9 Applications ........................11 Block Diagram .......................12 Specifications .........................13 Service Procedures ........................16 Schematic........................16 Parts List.........................16 Variations and Options ....................16 Warranty ........................16 PB-6207B...
  • Page 4: Unpacking

    BATTERY CHARGER Unpacking Unpacking Although your PB-6207B is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation. As with most electronic devices, we strongly recommend you retain the original packaging. In the un- likely event the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
  • Page 5: Features

    3. When power is applied. After checking whether the battery voltage is within the charging range (16V ≤ VBATT ≤ 28.5V), charging starts. 4. If the battery connected to the device is completely discharged, it will not be charged. PB-6207B...
  • Page 6: Equipment Setting And Checking

    2) Set the termination switch to LOAD only for the first and last-numbered equipment units. All others must be set to OPEN. Equipment 1 Equipment 2 Equipment 3 Equipment N S/W: LOAD S/W: OPEN S/W: OPEN S/W: LOAD ※ Caution: Communication error may occur if setting is performed incorrectly. PB-6207B...
  • Page 7: Front Panel

    - There is no voltage at one or more outputs. - Fuse (F401 or F201 to F206) is blown The fault signal is displayed via 3 LEDs on the front as well as 3 contact outputs on the rear panel for remote monitoring. PB-6207B...
  • Page 8 During the first impedance confirmation, the BATT LED blinks green/orange several times. If the impedance increases by about 100mohm from the stored value, a warning is activated when checking the impedance. Impedance warning repeats with a short cycle of beeps. PB-6207B...
  • Page 9: Rear Panel

    - Battery status. - Output voltage status. 7. BATTERY CONNECTION TERMINALS This is the terminal for connecting the battery. Be sure to configure the connection with the battery fuse breaker before connecting, paying attention to the polarity. (up to 120A). PB-6207B...
  • Page 10 10. TERMINATION SWITCH (LOAD/OPEN) This switch is set for stable data transmission/reception of LINK IN/OUT. For detailed setting method, refer to device setting and checking. (※ Caution: Communication error may occur if it is not set correctly.) PB-6207B...
  • Page 11: Equipment Setting And Checking Details

    In normal operating mode: The battery charger charges the battery and displays its status when fully charged. The maximum current that can be provided for battery charging (CHG) and auxiliary out- put (AUX) is 15A. When in backup operating mode: the battery provides the total operating current, which must not exceed 120A. PB-6207B...
  • Page 12 2) Low battery voltage protection Voltage threshold is 19.6VDC ± 10% for PB-6207B. - Discharge when there is no AC power to the battery charger Battery Charger When discharging without AC power, the battery charger discharges the battery to 19.6V.
  • Page 13: Applications

    BATTERY CHARGER Applications Applications SOURCE AMP ONLY UNSALITOHED DC PB-6207B PB-6207B...
  • Page 14: Block Diagram

    BATTERY CHARGER Block Diagram Block Diagram PB-6207B...
  • Page 15: Specifications

    BATTERY CHARGER Specifications Specifications PB-6207B Charge Complete Voltage 27.3V@25℃ Starting Current 10A MAX Auxiliary output voltage 24.3V Auxiliary output current 10A MAX Sum of charging and auxiliary output current 15A MAX (auxiliary output priority) Main output current (per port) 40A MAX...
  • Page 16 BATTERY CHARGER ※ DIMENSIONS PB-6207B...
  • Page 17 5. In case of fixing by not using the included screws or screws of the same size, or using insufficient number of screws the manufacturer is not responsible for any safety accidents caused by this. Accessories included for fixing the product - Specification: SCREW M5x0.8P, L=12 - Quantity: 4pcs PB-6207B...
  • Page 18: Service

    To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.
  • Page 20 Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).