Water
2
3
1
32
CAUTION
Damage to the unit caused by water
→ Check that the metal rings are positioned correctly.
3. Check that both metals rings (3) are lying on the respective plastic
sprocket in the threaded connector (2).
If not, open the threaded connector (2) and repeat the process.

5.2 Waste water connection

The unit is equipped with a siphon (odour trap) with an overflow and can
be connected to the waste water system without taking additional action.
Customer-supplied siphons should be avoided.
If the waste water outlet is connected to a customer-supplied siphon (1),
counter pressure may cause the siphon in the unit (3) to overflow.
Therefore, in this case, the waste water pipe must be fitted with an aerator.
A PA-I 1818 DIN 19560 HT pipe is recommended for the connection to
the waste water system.
The diameter of the waste water pipe must not be reduced.
1. Make sure that the customer-supplied pipes meet the requirements
for the waste water connection (see
water", Page
2. Observe the provisions for the disposal of waste water (see
"Waste water", Page
3. Connect the unit to the waste water system using a heat-proof pipe
(DN 40).
4. With customer-supplied siphons: connect aerator to a waste water
pipe.
5. With customer-supplied siphons: pour 2 quarts (2 l) of drinking water
into the siphon.
This ensures the siphon will work properly.
Planning and installation instructions
13).