Information About The Soft Water Supply - Henny Penny SPACE SAVER 605ESC63XXXX Planning And Installation Manual

Combisteamer (electric)
Table of Contents

Advertisement

Space$aver
2
1

5.1.1 Information about the soft water supply

Cl/Fe content
Supply pressure
Contamination of the water
Global Foodservice Solutions
7. When preparing the hoses, calculate the length to allow 0.8 m to
be pulled out from the unit after connection, for later servicing.
8. Rinse out customer-supplied hoses for the hard and soft water
connections.
9. Make sure that the filters fitted as standard to the unit's water inlets
are present.
CAUTION
Damages caused by incorrect water supply!
→ Do not confuse the hard water and the soft water connections.
NOTICE
The connections for hard and soft water are located on the floor of
the unit on the left.
10. Connect the hose for the hard water supply to the hard water
connection (1).
11. Connect the hose for the soft water supply to the soft water
connection (2).
If the Cl content is greater than 150 mg/l, Fe content greater
than 0.1 mg/l or Cl
in the cooking chamber. The Cl content can be reduced with an
activated charcoal filter.
If the supply pressure is not within the given limits (see
"Specifications, soft water", Page
fail to produce any steam.
If the water is heavily contaminated, a sedimentation filter (grit size
0.08 mm) must be installed upstream.
Planning and installation instructions
content greater than 0.1 mg/l, corrosion can occur
2
13), the cooking art "Steaming" will