Bosch HXS59AI.0Q User Manual And Installation Instructions page 48

Free standing cooker
Table of Contents

Advertisement

en Installation instructions
24.3 Selecting the gas connection side
On many appliances, you can carry out the gas con-
nection on the right- or left-hand side. If necessary, you
can change the connection side.
Requirements
¡ Shut off the main gas line.
¡ Seal the gas connecting piece on the side that is not
being used with a blind plug.
Place the new seal in the blind plug. Ensure that the
1.
seal is seated correctly.
Note: Use a torque wrench when connecting the ap-
2.
pliance.
Secure the gas connecting piece to the appliance
using a 22 mm spanner and place the blind plug
onto the connecting piece using a 24 mm spanner.
After changing the connection side, carry out a leak
3.
test. You can find additional information about this in
the section entitled "Leak and function test"
→ Page 53.
24.4 Gas connection
These instructions apply only if the appliance is in-
stalled in countries that are specified on the rating
plate.
If the appliance is installed and used in a country that
is not specified on the rating plate, add installation and
assembly instructions that contain the necessary in-
formation for the connection conditions for the appli-
ance in the respective country.
Note: Use a torque wrench when connecting the appli-
ance.
Natural gas connection (NG)
If you are using natural has (NG), the gas supply
should be connected via a gas pipe or a safety gas
hose with threaded fittings at both ends.
Connection types:
¡ *G½: EN ISO 228 G½ (TS EN ISO 228 G½)
¡ *R½: EN 10226 R½ (TS 61-210 EN 10226 R½)
WARNING ‒ Risk of explosion!
A gas leak may occur due to a damaged connection
nozzle.
When connecting the gas pipe or safety gas hose,
never tighten the gas connecting piece on the appli-
ance using a 22 m spanner. This may damage the
connecting piece.
48
SW
22
SW
24
20-25
Nm
Connection in accordance with EN ISO 228-1 G½ (TS
EN ISO 228-1 G½)
Insert the new seal in the connecting piece. Ensure
1.
that the seal is seated correctly.
Secure the gas connecting piece to the appliance
2.
using a 22 mm spanner and place the connecting
piece into the connecting piece using a 24 mm
spanner.
Place the new seal into the gas pipe or safety gas
3.
hose. Ensure that the seal is seated correctly.
Secure the connecting piece using a 24 mm span-
4.
ner. Use a 24 mm spanner to place the threaded fit-
ting of the gas pipe or safety gas hose on the con-
necting piece and tighten it firmly.
Open the gas connection shut-off. Carry out a leak
5.
test → Page 53.
Connection in accordance with EN 10226-1 R½ (TS
61-210 EN 10226-1 R½)
Insert the new seal in the connecting piece. Ensure
1.
that the seal is seated correctly.
Secure the gas connecting piece to the appliance
2.
using a 22 mm spanner and place the connecting
piece into the connecting piece using a 24 mm
spanner.

Advertisement