Morphy Richards PerformAir Manual page 6

Cyclonic vacuum cleaner
Hide thumbs Also See for PerformAir:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
71062MEE Rev2:Ion 441375253 Rev 1
E
ı
F
G
6
8/7/08
11:08
All manuals and user guides at all-guides.com
4
Close the bottom of the dust
canister by pressing the base
upwards until it clicks into place.
5
Refit the dust canister back into the
product. Make certain the dust
canister feet are located in place.
6
Close the lid securely.
ALLERGY
SUFFERERS
If the allergy sufferer is emptying the
product it is recommended that the
container is placed into a plastic
bag to empty.
1
Place the container inside the plastic
bag, releasing the
container with one hand whilst
holding the top of the bag closed
with the other, leave the dust to
settle for a few seconds before
carefully removing the empty
canister. The plastic bag can then
be sealed and disposed of.
FILTERS
Cleaning canister
filter
1
Access the filter assembly by
removing the lid. Press the lid
release button down then rotate the
lid E.
2
Use the filter cleaning brush to
remove any fluff from the outside of
the mesh filter or gently tap.
3
Rotate mesh filter anti-clockwise
to disassemble.
4
Shake the pleated filter to remove
any dust.
5
Both the mesh and pleated filters
may be washed (in cool water only)
but must be thoroughly air dried
before refitting.
6
To re-assemble, locate the pleated
filter into the lid then secure into
place with the mesh filter by rotating
the mesh filter anti-clockwise.
7
Fit the lid with filter assembly onto
the canister then rotate clockwise
until it locks into place.
IMPORTANT: Do not use detergents
to clean the filter. The filter should
be regularly washed, and must be
Page 6
thoroughly dry before the machine is
used.
The dust container may not lock
back onto the machine unless the
filter is fitted correctly
Exhaust filter
The exhaust filter  is located at
the rear of the cleaner. Press the
catch and pull the exhaust grille ‰
F
away
. Pull the bottom of the filter
outwards so the top of the filter
unhooks from the filter recess.
Foam filters may be washed (in cool
water), thoroughly air-dried and re-
fitted. The pleated filters used on the
Allergy models cannot be washed
and should be replaced every 6
months or sooner depending on
use.
IMPORTANT: To re-fit the filters, first
hook the top of the filter into the
filter recess then push the bottom of
the filter into location G.
Note: If the filter is not correctly
hooked in the exhaust filter grille will
not close.
After fitting the filter, re-fit the
exhaust filter grille by hooking the
bottom of the grille in first and then
pushing the top close until it clicks
fully closed.
IMPORTANT: All filters should be
checked regularly for signs of
damage, preferably after each
cleaning task. The filters must be
replaced immediately if they become
damaged.
Always disconnect the cleaner from
the mains when checking filters.
Always make sure all filters are fitted
before use. Failure to do so may
result in damage to your product.
Storage position
When finished you can store the
tubes and accessories by locating
the tube storage clip into the
parking slot on the side of the
cleaner as shown H.
Safety cut-out
If the cleaner overheats a motor
protection thermostat will

Advertisement

Table of Contents
loading

Table of Contents