Page 2
ntroduction Wireless GSM Burglar Alarm with voice prompt for commercial and home use is built on leading microprocessor technology with advanced GSM digital signal processing power. It is a highly integrated system of digital speech, mobile messages, multiple modes of wireless coding, long-distance home appliances controlling, SMS Messages identification and other technologies.
Page 3
This is for partial arming of the alarm system when there are people at home, only some of the selected sensors are activated and could be triggered by events. In a STAY ARM status, the panel [ARM ] light is flashing. To activate using remote control: press [STAY] key once.
Page 4
"beep", "beep" two short Exit configuration or learnt tones succeed "beep", "beep", "beep" three Error indication short tones Voice prompt The prompt voice of the function and status ARM LED Light up Alarm panel at ARM state Rapid flashes Alarm panel at STAY ARM state Flash slowly Alarm panel at delay ARM or...
Page 5
System default the GSM module is on . if the user not installed the SIM card , the host will restart until find SIM card and GSM signal. Remark: If set the GSM module to off, the alarm system only used as the live alarm system,only cleared the police , can not dialed the phone alarm number.Moreover ,the host without the SIM card would not restart when you closed the GSM module.
Page 6
addressing. 3.7 Delete detector Delete the sensor of first defence zone : press 【SET】 twice ,and then press 【SET】 3s when the first defence zone indicator light on ,the alarm panel beep twice ,means delete the detector of first zone successfully. Delete the sensor of second defence zone : press 【SET】three times ,and then press 【SET】3s when the second defence zone indicator light on ,the alarm panel beep twice ,means delete the detector of second zone successfully.
Page 7
Method two: Send SMS messages 12343113812345678# to a alarm panel (which at the beginning of 1234 is the user password), the alarm panel will reply with SMS message "Group 1 phone number :13812345678” to confirm the 1st group alarm phone number is set to13812345678 successfully. For users using the telephone line extension, you should dial the number 13812345678+*+extension number.Here one * means wait 1s,Two * means wait 2s .
Page 8
new password 】 + remote, press 504321# 【#】 Method two: Send SMS message 1234504321# Set delay for system Upon armed from the remote control or alarm panel, the alarm panel is set to delay 0 - 99 before at the ready status of ARM. Syntax: The system default is 00 seconds.
Page 9
Syntax: remote, press 550# 【55】 + 【 0/1 】 + Method two:Send SMS messages 1234550# 【 # 】 Set date and time Set the system date and time of July of 2012 9 :00 : 00 am settings Example: it is now 1 Method one: After calling and connected to the panel from Syntax: remote, press 56120901090000#.
Page 10
Example: Set zone number 2 as STAY zone type, and siren not sound upon alarming Method one: After calling and connected to the panel from remote, press 600220# Method two: Send SMS message 1234600220# Set mode of wired Set wired alarm zone to NO or NC. The zone number of 07-10 alarm zone are wired defense zones, system default is 07-10 are wired zones with NO mode.
Page 11
audible Alarm panel will produce audible confirmation beep upon receipt confirmation from of signal from remote control. 1 is on, 0 is off, default is on. panel to on or off Example: users need to disable the audible confirmation. Syntax: Method one:After calling and connected to the panel from remote, 【11】+【0/1】+【#】...
Page 12
status 6# panel replies AC power ON or AC power OFF. Query the alarm panel Query the alarm panel status included: arm/disarm, relay status, general settings status of integrated alarm, status of SMS messaging, 20+【#】 status of remote operation, password, delay alarming setting, delay arm setting, length of time of siren sounding, volume of siren, keyboard locking status, audible confirmation Example: Send SMS message 123420# to the alarm panel, the...
Page 13
23+【#】 1:Normal On means the first zone is normal zone,siren on. 2:Stay Off means the second zone for STAY alarm, siren off 3: Smart On means the third zone for INTELLIGENT,siren on 4: Urgent On means the fourth zone for EMERGENCY,siren on 5: Off On means the fifth zone for CLOSE, in close state 6: Normal On means the sisth zone for NORMAL,siren on 7: Normal On NO means the seventh zone is NORMAL,siren...
Page 14
password and thus should adjust the commands listed accordingly. Remote Control of Panel 5.1 After receiving the Panel Alert: After Panel alerts, it will automatically dial the preset telephone number for three times until connected ,and send SMS message to the preset telephone number . When the user picks up the phone, a piece of pre-recorded voice message will be played back immediately and let the receiver noted about the event.
Page 15
STAY Defense zone can be shut off solely through the remote control (AT-HOME Defense (keyboard) to avoid the Infrared Detectors and other zone) in-room detectors from misinformation when master is resting at home. INTELLIGENT if the detector in the Defense zone is triggered only once, Defense zone: it will not immediately alarm.
Page 16
alarm in home and the other one in office) P.S.: One APP supports more than one alarm system 3). Device number is the phone number of the sim card which you already put inside the alarm system. 4). Device password is the password of alarm system, the factory setting is 1234 2.Operate Back to the first home page,choose the device you added just now,then you can operate it.
Need help?