5. Starting
5. Starting
Check, whether
-
-
-
-
Plug in the mains cable of the control unit and switch on the control unit by the mains switch.
The optimal operative range of the linear feeder is at a controller position of 80% at the
control unit. In case of higher deviations (>=±15%) a readjustment should be carried out.
5.1 Adjustment
With spring assemblies for a conveying track weight, which is approx. 25 % lower than the
maximum track weight described in 1. Technical data, and a running speed of 4 - 6 m/min.
In case heavier or lighter conveying tracks are installed or considerably faster or slower
conveying speeds are required, the spring assemblies must be modified. For that the
following basic rules must be observed:
10
Ensure that the frame (stand, base, frame etc.) is connected
NOTE
with the ground wire (PE). If necessary, prediction earthing
on spot should be provided.
the linear feeder stands in an isolated position and does not come in securely with a
solid body
the linear track is screwed down and adjusted
the connecting cable of the linear feeder is plugged in at the control unit.
The electric connection of the linear feeder may only be made
by trained personnel (electricians). In case modifications are
made at the electric connection, it is necessary to observe the
WARNING
operating "Hardware (Hopper Controller)".
The available supply voltage (frequency, voltage, output) is in accordance with the
connection data of the control unit (see type plate at the control unit).redf
At first a rough adjustment of the conveying speed
(adjustment of the natural frequency) must be made, which is
NOTE
followed by the adjustment of the running behavior. Finally
you adjust the conveying speed (natural frequency).