8. Special Menu
This menu lets you adjust and set up the video signal
of the camera to meet your requirements.
Move the cursor to END on the bottom line of the CAM
SET UP menu and press
2 seconds or longer. The SPECIAL menu appears on
the monitor as shown below.
** CAM SET UP **
CAMERA ID
OFF
ALC/ELC
ALC
SHUTTER
---
AGC
ON
SYNC
INT
WHITE BAL
ATW
LENS DRIVE
DC
END
SET UP DISABLE
8-1. Chroma Level Setting (CHROMA GAIN)
1. Move the cursor to the CHROMA GAIN parameter.
2. While observing the vectorscope or colour video
monitor, move the "I" cursor to adjust the chroma
level.
8-2. Aperture Gain Setting (AP GAIN)
1. Move the cursor to the AP GAIN parameter.
2. While observing the vectorscope or video monitor,
move the "I" cursor to adjust the aperture gain
level.
or
simultaneously for
** SPECIAL **
CHROMA GAIN
....I....
AP GAIN
....I....
PEDESTAL
.I.......
-
+
CAMERA RESET
PUSH SW
RET
END
8-3. Pedestal Level Setting (PEDESTAL)
1. Move the cursor to the PEDESTAL parameter.
2. While observing the waveform monitor/oscillo-
scope or video monitor, move the "I" cursor to
adjust the pedestal level (black level).
To reset to the factory settings
1. Move the cursor to the CAMERA RESET parame-
ter. The words PUSH SW start blinking.
2. While holding down
seconds or longer. The camera is reset to the fac-
tory settings.
To close the SPECIAL menu and return to the CAM
SET UP menu
Move the cursor to RET and press
To close the SPECIAL menu and return to the
camera picture
Move the cursor to END and press