Venturi Apparatus ME-8598 Included Equipment Part Number Air Method: Recommended Equipment Part Number 1. Venturi Apparatus base and top plate ME-8598 Spirometer Sensor PS-2152 2. T-knob Screws (qty. 8) 617-024 One of the following: 3. Spirometer Tubing, 2.5 cm ID, 15 cm long 640-053 Shop Vacuum (or similar air supply) 4.
Pitot tubes, the Venturi Apparatus allows the quantitative study and verifica- tion of the Continuity Equation, Bernoulli’s principle, and the Venturi effect. The model ME-8598 Venturi Apparatus includes the connectors and tubing needed for doing the experiment with either air or water. This manual contains complete experiment instructions, including several options for fluid supply and flow-rate mea- surement.
Mo d el No . M E- 8 5 98 E x p er i m en t Setup Connect the Quad Pressure Sensor to your PASPORT interface (but do not connect tubing to the pressure ports Quad Pressure Sensor yet).
V en tu r i A p p ar a tu s 012-09486B E x p er i m en t straight, the pressure at Point 2 would be the average of P and P . Calculate this theoretical pressure: ------------------ (eq.
Mo d el No . M E- 8 5 98 A p pe n di x A : Q ua d P r es s u r e Ca l i br a ti o n Appendix A: Quad Pressure Calibration The purpose of this calibration is to fine-tune all four pressure measurements so they read the same when exposed to the atmosphere.
V en tu r i A p p ar a tu s 012-09486B A pp en d i x B : Fl ui d S u pp l y a n d Fl ow R at e Appendix B: Fluid Supply and Flow Rate Measurement Options You can conduct the experiment using air or water as the fluid.
Page 9
Part Number Spirometer Sensor PS-2152 Use the PASCO Spirometer sensor to measure airflow rate. The Spirometer is primary designed for measuring airflow in and out of a person’s lungs, but works well to mea- sure the airflow through the Venturi Apparatus.
Start data collection (by instructions included with pressing or clicking the Start button) with the air supply off, and wait until the spirom- it (PASCO instruction eter is ready before turning the air supply on. sheet 012-08856).
Page 11
Mo d el No . M E- 8 5 98 A pp e nd i x B : F lu i d S u pp l y a n d Fl o w Ra te Me a s ur e m en t O p t io n s Open the clamp to let some water through the apparatus;...
Page 12
V en tu r i A p p ar a tu s 012-09486B A pp en d i x B : Fl ui d S u pp l y a n d Fl ow R at e Install the three-step pulley on the rotary motion sensor. Clamp the rotary motion sensor above the reservoir (see Figure 10).
Mo d el No . M E- 8 5 98 A pp e nd i x C : Co ns t an t s ------ - ----- - (eq. 4) gρ where dF/dt is the rate of increasing force, g = 9.81 N/kg, and ρ = 1000 kg/m Water-flow Measurement Method 4: Stopwatch In this method, you measure a volume and elapsed time to determine the average flow.
For a description of the product warranty, see the PASCO catalog. Copyright The PASCO scientific 012-09486B Venturi Apparatus Instruction Manual is copyrighted with all rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, providing the reproductions are used only in their lab- oratories and classrooms, and are not sold for profit.
Mo d el No . M E- 8 5 98 T ec h n ic a l Su p po r t POLYSI TECHNOLOGIES, INC. Issued 4/7/95 5108 REX MCLEOD DR. Revision 3 4/1/2005 SANFORD, NC 27330 Phone: (919) 775-4989 Material Safety Data Sheet Page 1 of 2 Product...
Page 16
V en tu r i A p p ar a tu s 012-09486B Te c hn i c al Su p po r t POLYSI TECHNOLOGIES, INC. Revision: 3 4/1/2005 5108 REX MCLEOD DR. SANFORD, NC 27330 Phone: (919) 775-4989 Material Safety Data Sheet Page 2-2 Product # Barium Grease...