Electrical Requirements; 7601 Terminal Power Requirements; Peripheral Power Requirements; Ac Store Wiring Requirements - NCR RealPOS 60 Site Preparation Manual

Hide thumbs Also See for RealPOS 60:
Table of Contents

Advertisement

NCR RealPOS 60 Terminal Site Preparation

Electrical Requirements

7601 Terminal Power Requirements

The terminal's external power supply has a maximum output of 150 Watts and provides
power to the terminal and its powered peripherals.
Range
LOW (115) 100-127
HIGH (230) 200-240
Caution:
heat sources, away from possible liquid spills, and where there is adequate clearance for
cooling.
Note:
separate country-specific power cord must be ordered separately. Available NCR power
cords are described in the System Cables section.

Peripheral Power Requirements

The number of peripherals that the terminal can support is dependent upon which
peripherals are connected. For planning purposes, use the RealPOS 60 (7601) Release 1.0
Power Matrix (B005-0000-2404) for details on total power distribution.
Note:

AC Store Wiring Requirements

The customer must provide suitable AC power for the terminals, associated equipment,
and devices. We recommend a dedicated unswitched power line dedicated to the NCR
equipment installation. Refer to the NCR Workstation and Peripherals AC Wiring Guide
(BSTO-2115-53) for store AC wiring requirements. The AC outlet must be installed near
the terminal and easily accessible to the operator.
Nominal Vrms Minimum Vrms Maximum Vrms Input Current Max. Arms
90
180
Locate the power supply away from other electrical equipment, away from
The RealPOS 60 does not offer an AC convenience outlet for CRT power. A
This file requires Microsoft Excel to run.
136
2.2A
265
1.2A