Customer Enclosure - NCR RealPOS 60 Site Preparation Manual

Hide thumbs Also See for RealPOS 60:
Table of Contents

Advertisement

30

Customer Enclosure

Observe the following guidelines when placing the terminal inside an enclosure:
• Leave at least 90 mm (3.5 in.) in the rear and 40 mm (1.5 inches) of clearance on sides
• The enclosure must provide adequate ventilation.
• The enclosure doors must be of a type that allows adequate airflow through the
• The enclosure ventilation must maintain an internal temperature as close to room
and top.
enclosure from front to back.
ambient temperature as possible, and always below the maximum specified
operating temperature (40C / 104F).
NCR RealPOS 60 Terminal Site Preparation