Page 2
Audience This book is written for hardware installer/service personnel, system integrators, and field engineers. Notice: This document is NCR proprietary information and is not to be disclosed or reproduced without consent. Safety Requirements The NCR RealPOS 60 conforms to all applicable legal requirements. To view the compliance statements see the NCR RealPOS Terminals Safety and Regulatory Statements (B005-0000-1589).
Page 3
Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the product’s plug. Repair or replace damaged or worn cords immediately. References • NCR RealPOS 60 User Guide (B005-0000-1974) • NCR RealPOS 60 Hardware Service Manual (B005-0000-2013) • NCR RealPOS 60 Parts Identification Manual (B005-0000-2014)
Page 7
USB (5964) DVI to DVI PS/2 - RS-232 & Power (5964) Power (5942 12", 5966) VGA Extension Powered RS-232 (5975) Dual Cash Drawer Y-Cable Ethernet, 10/100/1000BaseT Cable PS/2 Keyboard Extension Cable RS 232 w/Power (5945/5992 EPT) AC Power Cables Appendix A: TransientProtection AC Power Line Transient Protection Data Line Transient Protection...
Page 8
viii Revision Record Issue Date Remarks Oct 2010 First Issue Jul 2012 Updated Solid State Optimization chapter Jun 2013 Release 2.0...
Introduction This document provides the information necessary to prepare a site to NCR specifications prior to installing an NCR RealPOS 60 terminal (also referred to as the NCR 7601). Prepare the site properly before installing the terminal because site preparation deficiencies may be difficult to detect and correct after installation.
Page 10
• a customer has been notified that a full or partial consultancy service is available and/or that NCR is willing to undertake a preliminary or final site survey and • the customer shall have entered into a formal contract with NCR for provision of the same.
• Provide and install floor coverings and environment systems that limit or control static electricity build-up and discharge In general, keep the NCR equipment area free from dust, smoke, lint, and other particles. Restrict smoking, eating, and drinking around the equipment. Avoid locating...
Third party peripherals must be certified with the POS terminal or a potential ESD issue can occur. Third party peripherals include any electrically powered devices connected to the POS terminal that is not an NCR branded product or a certified solution advocated by NCR. Examples of third party products include printers, external CD- ROM drives, cash drawers, cigarette boxes, pin pad devices, etc.
NCR RealPOS 60 Terminal Site Preparation Environmental Requirements Barometric Pressure The terminal operates within the following barometric pressure conditions: • Maximum operating altitude: 3,000 m (9,843 ft.) • Operating range of pressure: 105 to 69 kPa (15.2 to 10.0 lb./in.) Temperature The terminal operates over the temperature ranges shown below.
NCR RealPOS 60 Terminal Site Preparation Handling Components One person may move terminal system components. However, consider the following when moving the terminal or handling individual components. • Peripherals do not attach to the base unit and may slide off if the base unit is tipped.
NCR RealPOS 60 Terminal Site Preparation VESA Mounting Hole Dimensions The bottom chassis of the 7601 has a VESA hole pattern (100 mm) that can be used to mount the unit on any standard VESA mount.
NCR RealPOS 60 Terminal Site Preparation NCR 5964-K038/K039 Checkstand Mount The Checkstand Mount is fully adjustable between the minimum and maximum dimensions that are illustrated below. The DynaKey can also be rotated right and left of center (shown) by approximately 90 degrees, as well as tilted from a vertical position to...
NCR RealPOS 60 Terminal Site Preparation Tall Pole Mount There are four different length posts available for the 5975/5976 displays, in four inch increments. Note: Heights greater than 215 mm (8.5 in.) should be screwed to the counter top.
NCR RealPOS 60 Terminal Site Preparation Tall Pole Mount There are four different length posts available for the 5975/5976 displays, in four inch increments. Note: Heights greater than 215 mm (8.5 in.) should be screwed to the counter top.
NCR RealPOS 60 Terminal Site Preparation Service Clearance Requirements...
Page 36
NCR RealPOS 60 Terminal Site Preparation Above Left Side Right Side Front Behind Device mm (in.) mm (in.) mm (in.) mm (in.) mm (in.) 300 (11.8) 40 (1.5) 40 (1.5) 40 (1.5) 90 (3.5) 7601 Keyboard 100 (4) Cash Drawer 330 (13.0) -...
NCR RealPOS 60 Terminal Site Preparation Airflow Requirements Do not block the air vents on the terminal or peripherals. These vents are necessary for cooling.
NCR RealPOS 60 Terminal Site Preparation Customer Enclosure Observe the following guidelines when placing the terminal inside an enclosure: • Leave at least 90 mm (3.5 in.) in the rear and 40 mm (1.5 inches) of clearance on sides and top.
Note: The RealPOS 60 does not offer an AC convenience outlet for CRT power. A separate country-specific power cord must be ordered separately. Available NCR power cords are described in the System Cables section.
NCR RealPOS 60 Terminal Site Preparation Cable Routing Peripheral cable connectors are located on the rear of the unit. There is an additional USB port located on the front of the terminal...
NCR RealPOS 60 Terminal Site Preparation Cable Cover If a Cable Cover is present then cables from devices that may be located on top of the terminal can be routed down through the opening in the top of the Cable Cover.
NCR RealPOS 60 Terminal Site Preparation USB (5964) 497-0445078 - 1 m (1432-C158-0010) 497-0445079 - 4 m (1432-C158-0040) Powered USB (Terminal) (5964) 19.0 mm 19.0 mm Access Hole Diameters (0.75 in.) (0.75 in.) 23531a DVI to DVI 497-0446721 - 1.0 m...
NCR RealPOS 60 Terminal Site Preparation (Host Terminal) (Display) 38.0 mm 38.0 mm Access Hole Diameters (1.5 in.) (1.5 in.) Power (5942 12", 5966) 497-0428512 - 4 m 1416-C851-0040 Power Powered USB (Display) (Host Terminal) 19.0 mm 23.0 mm Access Hole Diameters (0.75 in.)
Improvement of any deficiencies in power quality is a customer responsibility. Malfunction and/or component failure as a result of power quality problems are/is not covered by the NCR Maintenance Agreement. NCR accepts no liability for any such occurrence nor for its consequences.
Note: NCR provides a full line of both AC power and data line transient surge suppressors to protect your RealPOS system and reduce downtime and extend the life of the RealPOS Retail Solution. For sizing and product information, please call NCR Site Preparation Services at 800-257-0458.