What to do if ...
Malfunction
The appliance is over-
cooling.
The freezer compartment
temperature is insufficient.
Interior illumination does
not function.
Accumulation of frost at
the door seal.
Unusual noises.
The compressor does not
start immediately after
pressing the FROSTMATIC
button, or after changing
the temperature setting.
26
Possible cause
The temperature has been
set too low.
Temperature is not properly
adjusted.
Door was open for a long
time.
Within the last 24 hours a
large quantity of warm
foods were loaded.
Appliance is next to a
source of warmth.
Light bulb is defective.
Door is not properly sealed
(perhaps after reversing
the door).
Appliance is not level.
Appliance is in contact
with wall or other objects.
A part at the back of the
appliance, e.g. a tube, is in
contact with another
appliance part or the wall.
This is normal, no error has
occurred.
Remedy
Temporarily select a higher
temperature setting.
Please refer to the section
"Temperature Adjustment".
Only leave the door open
as long as necessary.
Press FROSTMATIC button.
Please refer to the section
"Installation Location".
Please refer in this chapter
under "Replace light bulb" .
Carefully warm the door
seal with a hand-held hair
dryer at those points which
are not airtight (no warmer
than approx. 50°C). At the
same time, shape the
warmed door seal by hand,
so that it is again properly
seated.
Readjust the front levelling
feet.
Push appliance away a
short distance.
Bend this part away
carefully if necessary.
The compressor starts after
a period of time.