5 Servicing

Indoor unit

5.2 Indoor unit

5.2.1 Removing the service cover

1 Unscrew the 2 screws which are fixed to the lower front
cover and remove it.
2 Unscrew the 2 screws on the bottom of the upper front
cover.
3 Unscrew the screw on the top of the upper front cover
and remove it.
1
2
3
4
5

5.2.2 Replacement of the LCD Controller

1 Insert the tip of a slotted screwdriver into the notches
at the bottom of the holding bracket, push and turn
the slotted screwdriver and then remove the holding
bracket from the remote control switch.
53
SMGB0135 rev.0 - 06/2020
!
C A U T I O N
Take care, do not damage the LCD when removing the service
cover.
Pay attention of no falling off the service cover.
Take care when removing service cover; the parts inside the
unit could be hot.
?
N O T E
When reassembling, proceed in reverse way than disassem-
bling.
Please note that for the maintenance operations described be-
low, it will be necessary to remove the maintenance cover as
a first step.
2 Unplug the CN2 connector -1- from the LCD controller.
3 Remove the fixing screws (x4) -1- of the LCD controller
to the tank.
?
N O T E
When reassembling, proceed in reverse way than disassembling.
5
1
1

Hide quick links: