Odstock Medical Limited
USER INSTRUCTION MANUAL
OML LINQ
Model: OML LINQ
Model Version: 1.0
Software: V1.2
To be used in conjunction with the
OML Stimulator Instruction Manual
www.odstockmedical.com
TM
TM

Advertisement

Table of Contents
loading

Summary of Contents for OML LINQ 1.0

  • Page 1 Odstock Medical Limited USER INSTRUCTION MANUAL OML LINQ Model: OML LINQ Model Version: 1.0 Software: V1.2 To be used in conjunction with the OML Stimulator Instruction Manual www.odstockmedical.com...
  • Page 2: Table Of Contents

    Table of Contents Introduction and Key Features Precautions Attaching the Holder Removing the Holder Installing a Battery Joining Instructions Installing a Wired Footswitch Use and Care Instructions Miscellaneous Warranty Components and Accessories Specification and Operating Environment Fault Finding Description of Symbols Manufacturer Details...
  • Page 3: Introduction And Key Features

    Pace XL. Uniquely the OML ® LINQ can have two Wired Footswitches attached allowing for additional triggering options (refer to the OML LINQ : Addendum for Clinicians). The OML LINQ has been designed to allow the user to set the device up with their wireless stimulator. However some functions identified in this manual require a clinician to set them up.
  • Page 4: Precautions

    Odstock Medical Limited. Doing so will invalidate the warranty. 9. The OML LINQ must only be used with Odstock Medical Ltd products. 10. Before use check that the OML LINQ has no visual signs of damage.
  • Page 5 12. Like all wireless devices the OML LINQ should not be used in areas where wireless is prohibited (e.g. aircraft). The OML LINQ should be carried in luggage with the battery removed from the device. Revert to using the stimulator with a Wired Footswitch.
  • Page 6: Attaching The Holder

    Attaching the Holder 1. Ensure that the OML LINQ is positioned correctly in the Holder. 2. Push the OML LINQ into the Holder ensuring that both arms click into place into the slots on the side of the device. Arms...
  • Page 7: Removing The Holder

    Removing the Holder 1. Pull either arm of the Holder away from the OML LINQ 2. Gently lift the Holder away from the OML LINQ...
  • Page 8: Installing A Battery

    4. If present then remove the old battery. 5. Install the new battery with the positive side of the battery facing out from the OML LINQ . If installed correctly the blue light will flash once (please refer to image C).
  • Page 10: Joining Instructions

    5. Bring the stimulator and OML LINQ close to each other. 6. After a few seconds the stimulator will indicate that joining has been successful and the blue light on the OML LINQ will stop flashing. 7. Your OML LINQ is now joined.
  • Page 11 Flashing Blue Light Joining Button ‘Joining in Progress’ ‘Single Press’...
  • Page 12: Installing A Wired Footswitch

    Installing a Wired Footswitch Prior to inserting the footswitch plug into the socket make sure that there is no debris in the socket of the OML LINQ Insert the Odstock Medical Wired Footswitch into either socket of the OML LINQ .
  • Page 13: Use And Care Instructions

    Normal Use Normal use of the OML LINQ is defined as wearing the device in the Holder mounted to either a shoe or sock. Alternatively, the OML LINQ can be used without the Holder and placed directly in a sock.
  • Page 14: Miscellaneous

    If this occurs a small movement of the foot or force on the Wired Footswitch will wake up the OML LINQ Turning off the OML LINQ There is no off switch on the OML LINQ .
  • Page 15: Warranty

    Warranty OML LINQ is warranted for a period of one year from the date of sale or fitting. The following exceptions apply: • Footswitches are warranted for a period of one month • Leads and batteries Should the unlikely event of any failure of the device occur during the warranty period, the device should be returned to Odstock Medical Limited for inspection.
  • Page 16: Components And Accessories

    Product Code OML LINQ 01-001-0029 User Instruction Manual 11-003-0027 Clinician Addendum Card 11-003-0031 User Quick Start Card 11-003-0049 OML Warranty Card 11-003-0067 Black Wired Footswitch 22cm 01-005-0044 CR2430 Varta Coin Cell Battery 05-001-0004 Universal Foam Insole 01-005-0043 Optional Extras and Spares...
  • Page 17: Specification And Operating Environment

    Specification and Operating Environment Specification Battery VARTA, Lithium Coin Cell, CR2430, 3V Battery Life >3 weeks Dimensions 49 x 42 x 14mm Weight Materials ABS, Polycarbonate, Rubber Coating Without Holder Without battery Operating Environment Operating Temperature 0 to +45 Storage and Transport Temperature -25 to 70 Operating Relative Humidity 15 to 93%...
  • Page 18: Fault Finding

    Fault Finding...
  • Page 19: Description Of Symbols

    CE mark declares that the product meets the requirements of applicable EC directives. Use by date in the format of year/month. The OML LINQ contains an RF transmitting device. Protected against solid foreign objects of greater than 2.5mm and dripping water at an angle up to 15 degrees.
  • Page 20: Manufacturer Details

    FCC public notice DA00. 107. Transmitter. Quality of The OML LINQ™ is designed and tested to service have a response rate of less than 100ms latency depending on system configuration after the detection of a heel event.
  • Page 21 (such as home routers), the user should turn off the system and move away from the interfering equipment. Please refer to fault finding. Like all radio telemetry devices the OML LINQ™ should not be used while flying. Remove the battery to turn off the OML LINQ™ (page 8).
  • Page 22 Electromagnetic Compliance Electromagnetic Emissions The OML LINQ™ was tested a lead of the maximum length (footswitch – 0.6m) in a system with 2 ODFS® Pace XL and an OML Remote. Manufacturer’s declaration of electromagnetic emissions The OML LINQ™ is intended for use in the electromagnetic environment specified below.
  • Page 23 Electromagnetic Compliance Manufacturer’s declaration of electromagnetic immunity The OML LINQ™ is intended for use in the electromagnetic environment specified below. The customer or user of the OML LINQ™ should assure that it is used in such an environment. Immunity test...
  • Page 24 If the measured field strength in which the OML LINQ™ is used, exceeds the applicable RF compliance level above, the OML LINQ™ should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orientating or relocating the OML LINQ™.
  • Page 25 The OML LINQ™ is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the OML LINQ™ can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications...
  • Page 26 Regulatory Representatives Odstock Medical Limited is based in the United Kingdom. Odstock Medical Limited uses external bodies as representatives where required by local regulations. Any adverse incidences or regulatory problems should be reported via local representative. If in doubt please contact Odstock Medical Limited for advice.
  • Page 27 Notes Local contact information may be placed here.
  • Page 28 Manufacturer Details Manufacturer Odstock Medical Limited The National Clinical FES Centre Salisbury District Hospital Salisbury, Wiltshire, SP2 8BJ United Kingdom Tel: +44 (0)1722 439540 www.odstockmedical.com enquiries@odstockmedical.com Registered Company No. 5532620 Manual Revision: V5.0 Manual Part Number: 11-003-0027 User Manual, English, LINQ ©...

This manual is also suitable for:

01-001-0029

Table of Contents