9
Transport and storage of cordless tools and batteries
Transport
CAUTION
Accidental starting during transport !
▶ Always transport your products with the batteries removed!
▶ Remove the battery/batteries.
▶ Never transport batteries loose and unprotected. During transport, batteries should be protected from
excessive shock and vibration and isolated from any conductive materials or other batteries that may
come in contact with the terminals and cause a short circuit. Comply with the locally applicable
regulations for transporting batteries.
▶ Do not send batteries through the mail. Consult your shipper for instructions on how to ship undamaged
batteries.
▶ Prior to each use and before and after prolonged transport, check the product and the batteries for
damage.
Storage
WARNING
Accidental damage caused by defective or leaking batteries !
▶ Always store your products with the batteries removed!
▶ Store the product and the batteries in a cool and dry place. Comply with the temperature limits stated in
the technical data.
▶ Do not store batteries on the charger. Always remove the battery from the charger when the charging
operation has completed.
▶ Never leave batteries in direct sunlight, on sources of heat, or behind glass.
▶ Store the product and batteries where they cannot be accessed by children or unauthorized persons.
▶ Prior to each use and before and after prolonged storage, check the product and the batteries for
damage.
10

Troubleshooting

If a problem occurs, always observe the charge-status and fault indicator of the battery. See the section
headed Status indicators of the Li­ion battery.
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
Trouble or fault
The saw blade drops out.
The saw blade cannot be
inserted.
The orbital action cannot be
adjusted.
The orbital action doesn't
work.
The battery runs down more
quickly than usual.
The battery does not engage
with an audible click.
*2264216*
Possible cause
The saw blade is not correctly en-
gaged.
The clamping system is clogged
with foreign matter.
The clamping system is clogged
with foreign matter.
Foreign matter in the orbital-action
adjusting lever groove.
The orbital-action mechanism is
clogged with foreign matter.
The orbital-action adjusting lever is
in position "0".
Very low ambient temperature.
The retaining lug on the battery is
dirty.
2264216
Action to be taken
▶ Repeat the insertion procedure.
▶ Make sure that the blade holder
is fully open and that the saw
blade is pushed all the way in
against the spring resistance.
▶ Clean out the blade holder.
▶ Clean out the blade holder.
▶ Clean out the orbital-action
adjusting lever groove.
▶ Check whether foreign matter
is present in the area of the
orbital-action fork and clean it
out.
▶ Adjust it to the desired setting.
▶ Allow the battery to warm up
slowly to room temperature.
▶ Clean the retaining lug and
re-insert the battery.
English