Alignment and Adjustment

2-2 Mechanical Adjustment

Note : Refer to the Mechanical Manual ÒDX-9R (AC68-00001A)Ó for the adjustment and confirmation of
assÕy full deck.
2-2-1 The number and position of test point
Test point :
TP601 (Control Pulse)
TP602 (H'D S/W -Trigger)
TP301 (Envelope)
TP302 (Audio output)
TP303 (Video output)
2-2-1 ACE Head Position (X-Point) Adjustment
(See the 2-2-1(d) ACE Head Position (X-Point) Adjustment
on page 2-2 of the Mechanical Manual)
1) Playback the alignment tape (Color bar).
2) Intermittently short-circuit the two test points on
Main PCB to set the adjustment mode.
(See Fig. 2-2 and 2-3)
3) Press the Ò5Ó button of remote control then adjust-
ment is operated automatically. (See Fig. 2-1)
2-4
All manuals and user guides at all-guides.com
AUDIO OUTPUT
ENVELOPE
HEAD SWITCHING
Fig. 2-4 Location of Test point (Main PCB-Top View)
4) Connect the CH-1 probe to TP301 (Envelope) the
CH-2 probe to TP602 (HÕD switching pulse) and
then trigger to CH-1.
5) Insert the (-) driver into the X-Point adjustment
hole and adjust it so that envelope waveform is
maximum.