HDP135V6 DC Power Supply User Manual
I. Product Introduction
HDP135V6
power
supply
cost-effectiveDC power supply. It has four-digit LED
voltage and current display. It also has over voltage
protection (OVP), over current protection (OCP), over
temperature protection (OTP) and USB quick charging
functions.
II. Product Model
Model
CH
Output V/A
HDP135V6
1
35.2V/6.2A
HDP135V6A
1
35.2V/6.2A
HDP135V6B
1
35.2V/6.2A
HDP135V6S
1
35.2V/6.2A
III. PerformanceSpecifications
1 Rated Working Condition
AC input: 115 VAC ± 10%, 230 VAC ± 10%, 50/60Hz
Working Conditions: Temperature -10℃~40℃
Relative humidity ≤80%
Storage Conditions: Temperature -20℃~60℃
Relative humidity ≤80%
2 Specifications
All technical specifications can only be guaranteed
when the instrument is operated continuously for more
than 30 minutes at the specified operating temperature
(18℃ to 28℃).
Voltage
≤0.1% + 5mV
Load Regulation
≤0.01% + 5mV
Line Regulation
Set Resolution
10mV
≤0.1% + 1 digits
Set Accuracy
Readback
10mV
Resolution
≤0.1% + 1 digits
Readback Accuracy
Ripple
10mVrms
Current
≤0.2% + 3mA
Load Regulation
≤0.2% + 3mA
Line Regulation
Set Resolution
1mA
≤0.2% + 3mA
Set Accuracy
Readback
1mA
Resolution
≤0.2% + 3 digits
Readback Accuracy
Ripple
5mArms
OVP
0 ~ 35.2V ± 0.2%FS
Maximum Voltage
35.2V ± 0.2%
OCP
0 ~ 6.2A ± 0.2%FS
Maximum Current
6.2A ± 0.2%
is
a
high
quality,
LCD
RS232
AC input
digits
4
None
115/230VAC
4
None
230VAC
4
None
115VAC
4
Yes
115/230VAC
Quick Charge
Output
Voltage
5V ~ 12V
Range
Output Power
Maximum: 18W
DCP (Apple, Samsung and BC1.2),
Supported Quick
Qualcomm
Charging Protocol
Quick Charge Protocol FCP, Samsung
Quick Charge Protocol AFC
General Features
RS232 (Optional)
Baud rate: 2400
Remote Interface
Data bit: 8
Stop bit: 1
No parity check
115 VAC ± 10%, 230 VAC ± 10%,
AC Input
50/60Hz
Temperature -10 ℃ to 40 ℃
Working Conditions
Relative Humidity ≤ 80%
Temperature -20 ℃ to 60 ℃
Storage Conditions
Relative Humidity ≤ 80%
Cooling
Air cooling
Weight
2.2 Kg
Size
85 * 150 * 230 (mm)
IV.Front Panel
1 Voltage Display
2 Current Display
3 Save and Recall Keys M1 ~ M10
M1 ~ M4: Press [M*] once, and the indicator lights
up to display the group settings.Use the voltage and
current adjustment knobs to adjust the settings that
need to be saved, and then long press the [M*]key
until the indicator lights up, the settings will be saved
in the [M*] position.
M5 ~ M10: To use M5 ~ M10 to save and recall, use
it in conjunction with the [Shift] key.TakingM5 as an
example, press the [Shift]key and the [Shift]
QC2.0/QC3.0,
Huawei
1