Content Voltage source characteristics ..............1 Software Introduction ................. 2 System Installation ..................2 System Requirement ................. 8 Contact Us ....................8 Function Introduction ..................9 Menu ......................9 Voltage Setting..................10 Mode Setting ................... 12 Waveform Display ..................13 ...
PPS1004A Voltage source characteristics 1. Low ripple,low noise Support high precision and dynamic programming output Fast automatic test software Data automatic storage function 1) Software corrected standard instrument board design 2) support USB2.0 communication 3) Support UXI agreement 4) DC Input power range of +12~+18 5) Can match any other instrument 2.
PPS1004A software, as a user simple operation and practical control software of QINGDAO HANTEK ELECTRONICS CO., LTD, is applicable for PPS1004A series power supply of our company. It allows users to achieve though the computer control in the power supply on the front panel.
Page 5
PPS1004A 4. Choose a destination directory. Click 'Next' to continue. 5. Check the setup information. Click Next to start copying of files. 6. This status dialog is displayed during copying of files. User’s Manual...
Page 6
PPS1004A Updating Your System Configuration. 8. The installation is complete. User’s Manual...
Page 7
PPS1004A Note: If you encounter any firewall prompts, please select the allow operation. After the installation, there will be a shortcut on the desktop Install Driver 1. Connect the A-Type Plug of USB cable to your PC’s USB port. 2. Connect the B-Type Plug of USB cable to PPS1004A’s USB port. 3.
Page 8
PPS1004A 5. New hardware search wizard starts to search the driver. 6. New hardware search wizard starts to search. User’s Manual...
Page 9
PPS1004A 7. New hardware wizard installs software. 8. Finish new hardware search wizard. User’s Manual...
Disk Space 500M disk free space Screen resolution 800 x 600 Contact Us Name: QINGDAO HANTEK ELECTRONICS CO., LTD. Site: www.hantek.com Tel: +86-532-88703687 +86-532-88703697 Fax: +86-532-88705691 E-mail: service@hantek.com support@hantek.com ...
PPS1004A Function Introduction Menu Voltage Setting Mode setting Waveform Display Menu 1. File: Save date as .txt, .xls, and .doc file. Open: Open a document saved according to the specified format Save: Save a document generated according to mode selection in the form of text files Save as: Save a document generated according to mode selection in the form of text files or Excel or Word...
PPS1004A Voltage Setting Click “OFF” key to open CH1. The left light turns red, and we will see the following picture: There are three ways to set the volt value. 1. Click the right green panel, the voltage value will display in “VOLT_SET” column.
Page 13
PPS1004A 3. Please input the volt value in “VOLT_SET” column directly. Note: Input voltage rang is from 0.600V to 9.000V. After setting voltage, click key, actual output voltage displays in “VOLT_ACTUAL” column. Click the following key to expansion PPS1004A interface. Then, you will observe the following waveform in right waveform area.
PPS1004A Mode Setting User can set voltage value continuously by PPS1004A. 1. Mode There are two modes to set a list file. You can select 1*10 or 2*5 mode. 1*10: Set a ten-step list file; 2*5: Set two five-step list files. 2.
PPS1004A At the same time, you will observe the waveform in the right area. If click the key constantly, it will set the voltage value in the list circularly. ⑧ Click the key to stop setting voltage. And the actual output voltage displays in “VOLT_ACTUAL”...
Page 16
PPS1004A Note: If select “Millisecond”, input time interval range is from 100 to 1000. If select Second, Minute and Hour, input time interval range is from 1 to 100. User’s Manual...