MP range of bottle sampler products to enable laboratory based particle counting. The LPA2 is a solution for online monitoring of contamination in your hydraulic fl uid, providing an immediate hydraulic health check. It employs predictive maintenance procedures to help reduce downtime and in turn costs.
Page 4
Product Presentation The LPA2 is designed to measure and quantify the numbers of solid contaminants in Hydraulic, Lubrication and Transmission applications. The LPA2 is designed to be a laboratory accurate instrument suitable for “on-site’’ applications utilising hydraulic fluid as the operating medium. Please contact your local sales office for other operating fluid options.
Page 5
PRODUCT OVERVIEW Data logger The LPA2 includes a built-in data logger, which adds the facility to log and timestamp test results locally within an internal memory, even when not connected to a computer. • Test logging is determined by the log settings •...
BS EN 62262:2002 Degrees of Protection Provided for Electrical Equipment against External Mechanical Impacts (IK Code) • BS EN 60721-3-4: 1995 Part 3: Classifi cation of Groups of Environmental Parameters and their severities, Section 3.4 Date: July 2020 Signed: Phil Keep (Managing Director) on behalf of MP Filtri UK Ltd Automatic Particle Counters...
Product overview EC Declaration of Conformity Table of Contents What this guide is for 1 General warnings and information for the Operator General safety warnings Operator position and dangerous areas Dangers and Hazards that cannot be eliminated Personal Protective Equipment Precautions related to product handling of the Liquid Crystal Touchscreen display 2 Transportation and Storage Transportation and Handling Conditions...
Page 9
TABLE OF CONTENTS 5.12 Moisture Sensor 5.13 Alarms 5.14 Wiring 5.15 Bottle Sampling 5.16 Battery Charging 5.17 Printer Paper 5.18 Computer Analysis 5.18.1 Software Installation 5.18.2 Results Download 6 Troubleshooting / FAQ Misuse of Product Fault Finding Warranty Calibration Clean Working Practices 7 Reference Spare Product / Part numbers Com Ports...
It contains detailed information to enable you to master the full functionality of the device, as well as key information on safety, waranty, maintenance and accessories. At MP Filtri we are commited to customer service and hope this manual will help you to fully master the LPA2. Disclaimer As a policy of continual improvement, MP Filtri reserves the right to alter the specification without prior notice.
1 General warnings and information for the Operator 1.1 General Safety Warnings Do not operate, maintain or carry out any procedure before reading this manual. Any individual operating the unit shall wear the following Personal Protective Equipment: - Protective eyewear - Safety shoes - Gloves - Overalls (or other suitable protective clothing)
Page 13
GENERAL WARNINGS To allow rapid identification of the employees who must read this manual, definitions have been used with the following meaning: This is any individual whose task is to use the machine for production purposes. The operator is aware of all the measures taken by the machine manufacturer in order to eliminate any source OPERATOR of injury risk in the workplace and takes into account the operational constraints.
The operator should be trained to use this equipment. Care should be taken when connecting to live systems. Always connect to the LPA2 unit first then connect to a system. The waste should always be to atmosphere, failure to do so may result in damage to the unit and leakage of fluid.
1.5 Precautions related to product handling of the LPA2 Battery • It is recommended that the LPA2 be charged for a minimum of 24 hours prior to first use, to fully charge the internal battery Internal Cleaning • Do NOT clean the LPA2 or Bottle Sampler with Acetone or similar solvents that are not compatible with the seals in the LPA2.
The unit is shipped in a cardboard box with appropriate protective packaging and these should be recycled accordingly where possible. The packed weight of the LPA2 and accessories is 14 kg, the box dimensions are 60 x 50 x 40 cm. 2.2 Storage The unit should be stored in a suitable location away from the production area when not in use.
How to obtain service? To obtain service under the terms of this warranty, the customer is required to notify MP Filtri before the expiration of the warranty period and to return the item in accordance with MP Filtri product return policy. Any product returned for warranty repair must be accompanied by a full fault report specifying the symptoms and the conditions under which the fault occurs.
Page 19
MP Filtri Ltd maintains a policy of product improvement and reserves the right to modify the specifications without prior notice. 3.1 Warranty on Recalibration The LPA2 is guaranteed for 12 months upon receipt of the LPA2, subject to it being used for the purpose intended and operated in accordance with this User Guide.
30 ml. (dynamic): 10:00 24 ml. (bottle sampler): 8:00 15 ml. (continuous): 5:00 Data Storage Approximately 600 timestamped tests in the integral LPA2 memory Keypad & LCD Full size QWERTY keyboard and backlit graphical LCD Communication Options 9 pin D type RS232 serial port for direct connection to PC and software...
TECHNICAL SPECIFICATION 4.3 Physical attributes Dimensions 430 mm / 16.9” (W) x 260 mm / 10.2”(D) x 210 mm / 8.2” (H) Weight 9.8 kg / 31 lbs Hydraulics Connections INLET M16x2 test point OUTLET Quick release coupling Seal Material M/N version: static seals - FKM, dynamic seals: NBR S version: FFKM 4.4 Fluid characteristics...
5. Product Installation and General Operation 5.1 Installation Each LPA2 supplied consists of the following: • 1 x LPA2 (*) Specific model will be as per ordered item. • 1 x M16x2 microbore pressure hose, 1500mm long • 1 x 2000mm quick release waste hose for LPA2 •...
5.2 Online Operation NOTE: Unit features are turned off as factory standard. This includes the automatic print, moisture sensor test (if applicable). Should any of these be required they MUST be switch on prior to performing an analysis, please consult the relevant section of the operators guide on how to action this.
PRODUCT INSTALLATION 5.3 Main Test / Progress Screen Button 1 - Main Test Screen START - Starts sampling and emptying cycle Button 2 - STOP - Stops test at any point in the sampling/ emptying cycle. Next test will start with an emptying cycle before the test commences Button 3 - PRINT - Prints test results.
5.4 Analyser Settings Press the SET button (Button 5) to program the Analyser to your requirements. The main “Settings Screen’’ will be displayed. To alter the Analyser settings progress through the following routine from this screen 5.4.1 Test Ref Press 1 , then input your reference details e.g. “MACHINE 1” The press return the RETURN key. 15 characters maximum 5.4.2 Test Number Press 2 , then input the required test number e.g.
PRODUCT OPERATION Note the Analyser has 5 language options: 0. English (Default) 1. Italian 2. French 3. German 4. Chinese For selection of language proceed as follows: - Press 6. - Enter chosen value (e.g. 1 then press the return button for Italian). - Press key 0 (zero) - Press key 0 (zero) - Wait 5 seconds...
Results are automatically stored to memory. To download results follow instructions, section 5.18.2 5.6 Interpreting Results Please refer to MP Filtri’s Fluid Condition Handbook for hydraulic component manufacturers’ recommendations on standard cleanliness requirements for various applications. ISO4406 and NAS1638 cannot be directly compared.
Page 29
PRODUCT OPERATION Examples of the print out details for the various test options: Automatic Particle Counters...
The Analyser upper operating limit is set at 24/22/20. Tests that result in particle counts exceeding any scale number in the three part ISO code upper limit has the scale number replaced by an asterisk. Also, the associated particle counts on the printout are repla- ced by X’s.
15ml sampling test commences. The flush valve automatically opens at the end of the sampling cycle and remains open whilst the LPA2 is emptying to waste the sample fluid from the previous test. Additionally, depending on the time set for Minutes Between Tests, the flush valve operates as follows: •...
The Waste Fluid Hose must be discharged into a tank/ vessel vented to atmosphere. To conserve battery life, the LPA2 should be permanently connected to the power adaptor when it is operated in the continuous sampling mode.
Press Stop button 2 at any point in the cycle to end continuous sampling. The test status will show Idle. 5.11 Continuous Sampling - with Clean Alarm Levels - Alarm Mode 1 This operating mode is similar to the Basic Operation, but in this mode the LPA2 will stop testing when the specified clean alarm level is achieved.
Page 34
“Analyser Settings” Section 5.4. Testing will automatically continue until the Class number has been achieved at each of the six Size Codes. Also, the LPA2 will handle deviations from the above format intelligently. The size code can be out of order: 7F / 4A / 5C / 4B / 6E / 6D If any sizes are missing, they will be assigned the “*”...
Page 35
PRODUCT OPERATION Step 11 Press flush valve push button to open flush valve – push button illuminates to indicate valve is open. Leave valve open for at least one minute or 200ml of fluid, to remove any entrapped air and fluid from the previous test ensuring no cross-contamination between samples.
5°C to 10°C less than the actual system temperature, depending on operating conditions. The LPA2 can be configured to do a test with or without the moisture sensor selected. If the moisture sensor has been selected, the flush valve will open automatically for a period of 3 minutes before the particle count test commences. This is to allow the moisture sensor to stabilise and give an accurate reading.
Page 37
PRODUCT OPERATION The LPA2 includes two solid state relays for connections to an external circuit. These can be arranged to function as follows: 1 Alarm Mode: 0 Selecting option 0 switches relays 1 and 2 always off. 2 Alarm Mode: 1 Selecting option 1 will configure relays 1 and 2 as described on page 36 - refer to the examples given on the simple wiring diagrams.
5.14 Wiring The LPA2 contains two solid state relays which can be used to switch an external circuit, when using the Continuous Test mode. The function of these relays for Alarm Mode 1 is shown in the following simple wiring diagrams, using a battery and bulb circuit for illustrative purposes.
5.15 Bottle Sampling Press the Log button 6 to access results stored within the LPA2’s memory, the Log Screen will be displayed. To view the contents of the LPA2’s memory progress through the following routine •...
The LPA2 is equipped with an internal rechargeable battery capable of sustaining 8 hours continuous operation following an initial 24 hour charging period (approximately 100 tests). To conserve battery power the LCD screen is illuminated at a reduced level when the LPA2 is operated without an external power supply connected.
PRODUCT OPERATION 5.17 Printer Paper To access the thermal printer, remove the four thumbscrews securing the cover and serrated paper cutter. Thermal printer paper is sensitised on one side only and must be fed into the printer mechanism as shown below. Using a finger, press down on the print head spring at position A and tilt the print head to the open position by pulling it back at point B.
Install software on to a suitable PC running Windows XP or later. Follow instructions as detailed in the LPA-View User Manual. 5.18.2 Results Download Step 1 Connect the cable to LPA2 and PC via an appropriate port. Step 2 Switch ON the LPA2. Step 3 Switch ON the PC.
(minimum 2 bar maximum 400 bar) (29 - 5800 PSI) • Connection hoses should never be allowed to lie along the floor when the LPA2 is installed and in use. • The operator should follow all standard operating procedures previously set at the operating location as well as the procedures required by the manufacturer.
Please ensure that the test results in the Log are downloaded to LPA-View before the LPA2 is despatched, in case action taken by MP Filtri during the service / recalibration causes the Log to be cleared. Please go to mpfiltri.com to book a time slot for service and recalibration.
6.5 Clean Working Practices The majority of hydraulic systems require cleanliness levels below 40 micron - the threshold of human eyesight. When analysing particles down to levels of 4um, 6um & 14um you are talking about objects of a cellular/bacterial size. This creates various challenges, and is starting to drive better and cleaner working practices in industry.
For spares and part numbers please see the website: www.mpfiltri.com 7.2 Com Ports The LPA2 uses the RS232 connection standard to interface with a computer. If the computer does not have a built-in RS232 (“COM’’) port, a USB:RS232 adaptor can be used.
Page 50
The data and information contained in this publication are provided only for the purpose of information. MP Filtri reserves the right to make changes to the models and versions of the products described at any time, both for technical and commercial reasons.
Need help?
Do you have a question about the LPA2 and is the answer not in the manual?
Questions and answers