FURUNO
4.6 Vertical Scan Mode Control
4.7 Transceiver Beam Width
4.8 Allowable Ship's Speed
4.9 Stabilization
5.
I/O INTERFACE
5.1 Data Format
5.2 Input
5.3 Output
6
POWER SUPPLY
6.1 MU-100C/Control Unit, Transceiver Unit
6.2 Control Unit, Transceiver Unit
6.3 Hull Unit
7.
ENVIRONMENTAL CONDITIONS
7.1 Ambient Temperature
7.2 Relative Humidity
7.3 Waterproofing
7.4 Vibration
8.
COATING COLOR
8.1 Control Unit
8.2 Transceiver Unit
8.3 MU-100C
Scanning angle: 6° to 180°, 12° step
Scanning center: 0° to 180°, 6° step
Scanning step angle: Normal: 3°, High speed: 6°
Time to train: 360°, 6° step
Frequency
Horizontal
60 kHz:
16°/22°
85 kHz:
11°/15°
153 kHz:
7°/9°
215 kHz:
5°/6°
20 knot or less (15 knot during raise/lower operation)
Within 30°, optional motion sensor required
IEC61162-1 (NMEA0183 Ver 1.5/2.0)
DBS, DBT, DPT, GGA, GLL, HDG, HDM, HDT, MDA, MTW, RMA,
RMC, VDR, VHW, VTG, att (P sentence)
SSTLL
12-24 VDC: 7.0-3.5A
12-24 VDC: 5.0-2.5A
12/24 VDC: 4.7/2.3A (16.7/8.2-A, during raising and lowering)
-15°C to +55°C (Soundome: 0°C to +35°C)
Less than 95%
Control unit: IPX5
Transceiver unit: IPX0
Hull unit: IPX2
MU-100C: IPX5
2 Hz-5Hz to 13.2 Hz: Amplitude: ±1 mm ±10%
13.2 Hz to 100 Hz: Max. acceleration 7m/s
Panel: N3.0, Chassis: 2.5GY5/1.5
2.5GY5/1.5
Panel: N3.0 Newtone No.5, Chassis: 2.5GY5/1.5
SP - 3
CH-300
Vertical
14°/20°
10°/14°
5°/8°
4°/6°
2
, fixed
E125S01A