Refrigerant System Diagnosis Cooling; Refrigerant System Diagnosis Heating - Friedrich H)A09K25L Service Manual

Single package vertical air conditioning system r410a models vert-i-pak a series
Table of Contents

Advertisement

PROBLEM
LOW SUCTION PRESSURE
Low Load Conditions
Low Air Flow Across
Indoor Coil
Refrigerant System
Restriction
Undercharged
Moisture in System
PROBLEM
LOW SUCTION PRESSURE
Low Air Flow Across
Outdoor Coil
Refrigerant System
Restriction
Undercharged
Moisture in System
34
TROUBLeshOOTINg ChART - COOLINg

REFRIGERANT SYSTEM DIAGNOSIS COOLING

PROBLEM
HIGH SUCTION PRESSURE
High Load Conditions
High Air Flow Across
Indoor Coil
Reversing Valve not
Fully Seated
Overcharged
Defective Compressor
TROUBLeshOOTINg ChART - heATINg

REFRIGERANT SYSTEM DIAGNOSIS HEATING

PROBLEM
HIGH SUCTION PRESSURE
Outdoor Ambient Too High
for Operation in Heating
Reversing Valve not
Fully Seated
Overcharged
Defective Compressor
PROBLEM
LOW HEAD PRESSURE
Low Load Conditions
Refrigerant System
Restriction
Reversing Valve not
Fully Seated
Undercharged System
Defective Compressor
PROBLEM
LOW HEAD PRESSURE
Refrigerant System
Restriction
Reversing Valve not
Fully Seated
Undercharged
Defective Compressor
PROBLEM
HIGH HEAD PRESSURE
High Load Conditions
Low Air Flow Across
Outdoor Coil
Overcharged
Non-Condensables (air)
PROBLEM
HIGH HEAD PRESSURE
Outdoor Ambient Too High
For Operation In Heating
Low Air Flow Across
Indoor Coil
Overcharged
Non-Condensables (air)
in System

Advertisement

Table of Contents
loading

Table of Contents