This is an unpublished work the copyright in which vests in Comba International ("Comba"). All rights reserved. The information contained herein is confidential and the property of Comba and is supplied without liability for errors or omissions. No part may be reproduced, disclosed or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.
EQUIPMENT MANUAL FOR RD-9120 0.2 CONTENTS Section Page CONTENTS ...........................2 INDEX TO FIGURES AND TABLES ..................4 HISTORY ..........................5 ISSUE CONTROL........................6 REFERENCES ........................7 GLOSSARY OF TERMS......................8 SAFETY NOTICES AND ADMONISHMENTS ..............9 SERVICING POLICY AND RETURN OF EQUIPMENT............10 0.10 READERS COMMENTS......................11 GENERAL INFORMATION....................12 EQUIPMENT DESCRIPTION ....................14...
Page 3
EQUIPMENT MANUAL FOR RD-9120 APPENDICES ........................43 APPENDIX A: TOOLS AND EQUIPMENT FOR INSTALLATION........43 APPENDIX B: VSWR – RETURN LOSS TABLE ..............43 APPENDIX C: UPLINK ATT AND NOISE LEVEL ...............43 APPENDIX D: INSTALLATION OF OMT ................44 7.4.1 ENVIRONMENT FOR OMT OPERATION ................44 7.4.2...
EQUIPMENT MANUAL FOR RD-9120 0.4 HISTORY Change No. Details Of Change 1-0-0 Created and issued in June 2006 Updated base product name: RD-9120 = R-9110AC RD-9120 QE Copyright - refer to title page Page 5 ENU Status : 1-0-0...
EQUIPMENT MANUAL FOR RD-9120 0.6 REFERENCES 0.6.1 R-9110AC QE 1-2-0 Equipment manual created for product variants on the product list plus product variant of 1W model and released in Jan 2006. 0.6.2 R-9110 AC datasheet Datasheet for product variant of 1W released Issue: B on 7 April 2005.
EQUIPMENT MANUAL FOR RD-9120 0.7 GLOSSARY OF TERMS Abbreviation Definition Automatic Level Control Attenuation Base Station Base Transceiver Station Channel Decibel Decibels relative to 1 milliwatt Downlink Donor Terminal Duplexer EEPROM Electrically Erasable Programmable Read Only Memory Frequency Selector Global Standard for Mobile Communication...
EQUIPMENT MANUAL FOR RD-9120 0.8 SAFETY NOTICES AND ADMONISHMENTS This document contains safety notices in accordance with appropriate standards. In the interests of conformity with the territory standards for the country concerned, the equivalent territorial admonishments are also shown. Any installation, adjustment, maintenance and repair of the equipment must only be carried out by trained, authorised personnel.
0.9 SERVICING POLICY AND RETURN OF EQUIPMENT The repair of individual units and modules of this equipment is not considered practicable without factory facilities. It is, therefore, the policy of Comba whereby faulty units or modules are returned to the local agent for repair.
EQUIPMENT MANUAL FOR RD-9120 0.10 READERS COMMENTS Whilst every endeavour is made to ensure the accuracy of this and all Comba documents, there is always the possibility that an inaccuracy or omission could occur. In order that any amendment/remedial action can be carried out promptly, we would appreciate your co–...
Remote configuration and surveillance is possible through Comba’s remote control and monitoring system, via PC or wireless modem to the OMC. Li-ion backup battery built in enclosure ensures alarm signals are sent out while power is down.The RD-9120 comes in a sealed, cast aluminum chassis, suitable for all weather conditions.
Page 13
EQUIPMENT MANUAL FOR RD-9120 Shown below are the mechanical drawings of RD-9120 enclosure. Figure 1: Front, side and bottom views of the equipment End of section RD-9120 QE Copyright - refer to title page Page 13 ENU Status : 1-0-0...
Li-ion Alarm Data card Main Control Unit Supply BATT Indicator Modem Wireless Modem External Power Figure 2: RD-9120 functional block diagram 2.2 EQUIPMENT LAYOUT DL LNA UL LNA Li-ion battery DL FS UL PA Distribution board Surge Wireless modem protector...
Page 15
EQUIPMENT MANUAL FOR RD-9120 Typical RD-9120 unit consists of the following components: Low Noise Amplifier (LNA): One Low Noise Amplifier (LNA) is installed in each UL/DL branch. The repeater UL/DL ATT value corresponds individually to UL/DL LNA gain. Frequency Selector (FS): The FS is used to select the demand carriers and reject unwanted signals effectively.
Page 16
EQUIPMENT MANUAL FOR RD-9120 Power Supply Unit (PSU): The PSU converts the input 220VAC into stable DC to supply power to FS, PA, LNA, MCU and to charge Li-ion battery. Surge protector: The surge protector is mounted next to the PSU. Within it there are three connections: 220V VAC Live, Neutral and ground.
EQUIPMENT MANUAL FOR RD-9120 2.3 MANUFACTURING ENTITIES RD-9120 is composed of modules with the following identifiers. Identification Code Description PA-4250CSS00D Downlink power amplifier PA-4250CSS00U Uplink power amplifier FB-C947.5B25SS06 Downlink frequency selector FB-C902.5B25SS06 Uplink frequency selector LA-1439C1SS01 Low noise amplifier FD-U902.5D947.5B25SS01/03...
EQUIPMENT MANUAL FOR RD-9120 2.5 TECHNICAL SPECIFICATIONS 2.5.1 ELECTRICAL AND POWER Model Electrical Frequency Range, Uplink 890 – 915 Frequency Range, Downlink 935 – 960 92 ± 2 Maximum System Gain Gain Adjustment Range (1dB step) 0 – 30 Operating Bandwidth 2 –...
Fault, Chassis Lock, Self oscillation, DL Input Power Local and Remote Monitored Parameters Low, Over Temp, UL/DL Output Power Low), UL/DL Output Power, DL Input Power Table 5: Management of RD-9120 End of section RD-9120 QE Copyright - refer to title page...
EQUIPMENT MANUAL FOR RD-9120 3 INSTALLATION 3.1 WARNINGS AND ALERTS Radio Frequency energies There may be situations, particularly workplace environments near high- powered RF sources, where recommended limits for safe exposure of human beings to RF energy could be exceeded. In such cases, restrictive measures or actions may be necessary to ensure the safe use of RF energy.
The equipment must not be opened for installation or maintenance in bad weather (e.g. gale, storm rainfall, extreme temperatures and high humidity) Installation location Mounting surface shall be suitable to support weight pf the equipment. For RD-9120, it is about 37 kg (82 lb.). Environmental Humidity has an effect on the reliability of the equipment.
EQUIPMENT MANUAL FOR RD-9120 3.2.1 REPEATER INSTALLATION CHECKLIST Installation Location Requirement Considerations Ample space on mounting pole or wall surface Working Space available Recommended space: 800mm x800mm x800mm Power cord length is no less than 2m, use a dedicated VAC power: AC breaker or fuse circuit, and with good access to an 176 –...
EQUIPMENT MANUAL FOR RD-9120 3.4 MOUNTING OPTIONS 3.4.1 MOUNTING RACK The following figure shows the dimension of mounting rack, which is used for mounting the equipment to either a wall or on a pole. Figure 5: Mounting rack dimensions The mounting rack is pre-installed for shipment. Follow the following steps to separate the mounting rack...
EQUIPMENT MANUAL FOR RD-9120 3.4.2 WALL MOUNTING DETAILS This manual takes mounting the equipment with relatively small enclosure as an example. Mount the equipment to the wall according to the following steps: Drill four holes on the wall using the mounting rack as a guide. Then fix the mounting rack to the wall using four masonry bolts (M10X110).
3.4.4 DRIP-LOOP Comba recommends that every horizontal cable entry to the equipment forms a 'U' before its entry to the equipment. Any accumulated water on the cable will drip down at the bottom of the loop and will not climb up to the equipment.
EQUIPMENT MANUAL FOR RD-9120 3.4.5 EQUIPMENT CONNECTIONS The equipment has been designed for all cable entries from the bottom of the enclosure. The only exception is the RS232 connection where it a temporary connection for equipment commissioning. DT ANT MT ANT...
Page 28
EQUIPMENT MANUAL FOR RD-9120 Powering option: -48V connectivity The DC power cable for -48V is color coded, typically as BLUE for “-48V or Battery” and BLACK for “0V or Return” connections. On the PSU is a Combicon connector (plug), please consult the PSU pinout and identify the -48V and 0V pin and wire the DC power cable to the -48V and Return pin.
EQUIPMENT MANUAL FOR RD-9120 4 COMMISSIONING 4.1 MCU LED INDICATORS Four diagnostic LEDs are located on the MCU, each indicates the status of a particular function: Identifier Colour Indication Online programming. This will flash when users read, set or download files via OMT.
OMT software is based on Windows operation system, and is designed for monitoring and maintaining of Comba repeaters and boosters. For RD-9120 repeater, the OMT software can accomplish the following functions: To configure and adjust the repeater’s operating parameters To display the repeater’s internal operation status...
EQUIPMENT MANUAL FOR RD-9120 4.5 PREPARATION REMOTE CONNECTION USING WIRELESS MODEM An integratged wireless modem with the equipment provides the option of remote connection of the equipment by OMT. The wireless modem implements the link for data and SMS. The power cable and data wire has already been connected to the wireless modem, customer only need to insert the SIM card into the wireless modem.
OMT Explorer software window will pop up, as shown below. Figure 11: OMT explorer window Double click ‘RD-9120 GSM900 Bandwidth adjustable Repeater’ in the left window, or click ‘AutoLink’ icon on the toolbar to connect the equipment to the OMT, by doing so the following window will appear.
Page 33
EQUIPMENT MANUAL FOR RD-9120 Figure 12: OMT screenshot - connection to the equipment Select ‘Local Connection’ in the above window, the window for choosing serial port will pop up. Figure 13: OMT screenshot - communication setup In the above window select the desired communication port and then click ‘Ok’ button to continue. Click ‘Online’...
Page 34
EQUIPMENT MANUAL FOR RD-9120 Enter the correct phone number and click ‘Dial’, wait until the system indicates ‘Online Ok’. Note: For remote connection, please ensure that SMS center number is set already before remote connection. Otherwise, a window will pop up indicating to set the SMS center number.
EQUIPMENT MANUAL FOR RD-9120 4.7.1 DESCRIPTION OF PARAMETERS The parameters being described are applicable to the RD-9120 variants. 4.7.1.1 NETWORK PARAMETERS The following parameters are located on the left of the main screen, these include: Site Address, SMS and data link parameters, all of enables communication with the OMC located in a Network Operation Centre.
Page 36
EQUIPMENT MANUAL FOR RD-9120 4.7.1.2 RF PARAMETERS The RF parameters include: PW On/Off, Oscilation On/Off, master ATT (UL/DL), temperature, assistant ATT (UL/DL), gain (read-only), uplink freq., downlink freq., VSWR threshold, power threshold (UL/DL) and field threshold. Identifier Application Setting 1...
Page 37
EQUIPMENT MANUAL FOR RD-9120 4.7.1.3 ALARM LIST The Alarm list for the RD-9120 is shown below, these are enabled/disabled with OMT/OMC by placing a ‘tick’ in the adjacent box against the required alarm condition and select ‘Set’: Alarm name Observations UL / DL LNA Monitor whether uplink/downlink LNA is normal.
Page 38
EQUIPMENT MANUAL FOR RD-9120 4.7.1.4 ALARM ACKNOWLEDGEMENT As and when the designated Alarm occurs, it will be visible on OMT and/or reported to OMC. If OMC does not acknowledging after a time-out of three minutes, the same alarm will be reported to OMC.
Observation 1. On-line & inquiry status Enter into RD-9120 Main window. Initialization of monitoring system will be up in about 2 minutes, at that time, on MCU L4 is off and L3 begins to flash. Click ‘online’ button and inquiry the repeater’s status.
EQUIPMENT MANUAL FOR RD-9120 4.9 REMOTE MONITORING USING OMC OMC offers flexibility to manage a network of equipment, all the tasks carried out by the OMT can performed centrally from the OMC terminal. In order for OMC to communicate to each equipment, an unique equipment identification must be referred to, and it is entered using OMT after local commission has been completed.
EQUIPMENT MANUAL FOR RD-9120 5 OPERATION Following installation and commissioning, occasional operation tasks to handling alarms may be required: Alarm condition Diagnosis Power down / power fault Check AC power cable and verify AC mains supply is normal. During power alarm fault alarm, DC power supply has no output.
Make sure the cable gland and sealing on the RF cable connectors are not damaged. Verify lightning and grounding protection is in good condition. For the Li-ion back-up battery, verify its state. Deeply discharged battery shall be return to Comba for replacement.
EQUIPMENT MANUAL FOR RD-9120 7 APPENDICES 7.1 APPENDIX A: TOOLS AND EQUIPMENT FOR INSTALLATION Shown below is the list of the recommended tools for new installation and routine maintenance Description Slotted screwdriver Phillips screwdriver Ring spanner (M10) Electrically operated drill and masonry drill bits...
Operation and Maintenance Terminal (OMT) is windows-based software designed for the control and maintenance of Comba repeaters. Installed in a PC, it performs the operation on the repeat either by local connection via RS232 cable or remote connection via wireless modem.
EQUIPMENT MANUAL FOR RD-9120 7.4.2 INSTLLATION OF OMT Copy installation programs by creating a new folder on the hard disk and give it a name. Then copy all the files from the installation disk to the newly created folder. Double click the OMT Explorer 2.10 software setup logo Figure 16: OMT software installation window When the message window appears, select ’Next’, the following pop-up window appears:...
Page 46
EQUIPMENT MANUAL FOR RD-9120 Create the installation folder and select ‘Next’, OMT Explorer installation would be finished as the following window appears: Figure 18: Installation of OMT explorer completed Select ‘Finish’, the OMT Explorer installation is completed. At this stage, OMT Explorer 2.10 software icon will be shown on the desktop.
” setup icon. Follow the instructions until the following window is shown. Select “Finish” to complete the installation. Figure 19: Installation of RD-9120 component completed At this stage, OMT could be executed immediately by selecting ‘Launch OMT explorer V2.10 immediately’.
‘Ok’, the component will be uninstalled. g) Double click the OMT software icon can also uninstall it from the PC. Figure 20: RD-9120 component unistallation - confirmation 7.4.5 OMT EXPLORER UN-INSTALLATION To uninstall OMT explorer software from the PC, follow the steps: a) Select: “START”...
EQUIPMENT MANUAL FOR RD-9120 7.5 APPENDIX E: OMT EXPLORER V2.10 INTRODUCTION The OMT Explorer V2.10 software providing the functionality of one OMT can manage a group of products, originally one OMT will manage one equipment. When the equipment is physically connected to the OMT software, click the [Autolink] button in the on the toolbar (see the following figure), OMT Explorer can automatically recognize the corresponding product OMT software.
EQUIPMENT MANUAL FOR RD-9120 7.5.1 PULL DOWN MENU Identified as part 1 of the screen The command menu bar of the window presents the options, which illustrates the commands that can be executed from the various options. Menu item •...
EQUIPMENT MANUAL FOR RD-9120 7.7 APPENDIX G: RMA (RETURN MATERIAL AUTHORIZATION) FORM End of section End of Document RD-9120 QE Copyright - refer to title page Page 56 ENU Status : 1-0-0...
Need help?
Do you have a question about the RD-9120 and is the answer not in the manual?
Questions and answers