Performance Monitoring/Metering Items - NEC PASOLINK+ Manual

6-38 ghz 155 mb digital radio system
Table of Contents

Advertisement

+
PASOLINK
155 MB 1+0/1+1 SYSTEM
6.9

Performance Monitoring/Metering Items

Item
OFS
BBE
ES
SES
UAS
TX PWR
RX SIGNAL LEVEL
ODU PS IN VOLTAGE
BER MEASUREMENT
Control Item
• IF Loop Back
• Baseband Loop Back (near end)
• Base band Loop Back (far end)
• Modulation off (CW control)
• TX Power mute
• TX/RX compulsive switching
Description
Sum of out of frame seconds
Sum of the background block error
Sum of the errored seconds
Sum of the severely errored seconds
Sum of the unavailable seconds
Transmitter output power
Receiver input level
ODU input voltage
Bit error rate
- 28 -
MTD-PL-028/141005
Remarks
MUX/RADIO direction
MUX/RADIO direction
MUX/RADIO direction
MUX/RADIO direction
MUX/RADIO direction
Metering item
Metering item
Metering item
Metering item

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents