Events; Indication - NEC PASOLINK+ Manual

6-38 ghz 155 mb digital radio system
Table of Contents

Advertisement

MTD-PL-028/141005
7) Mechanical Dimension
ODU
IDU
1 + 0
1 + 1
Note*: Including option panel
Note : Salt damage
In case of operating in the sea or around the coast area (within 3 km from coastline),
measure must be taken for the ODU against salt damage. Please ask NEC for
countermeasure.
6.5

Events

Alarm Events for 1+0 system
Event
LOS
Input signal lost (Input STM-1 signal)
LOF
Frame synchronization lost (Input STM-1 signal)
INTFC ALM
STM-1 interface unit failure, Loss of output STM-1 signal
BER (RX) ALM
Excessive BER
BER degraded worse than preset value (10e-3 to 10e-
5)
MOD ALM
TX side alarm includes unit failure, IF output signal
degraded.
DEM ALM
RX side alarm includes unit failure, IF signal input lost.
WS ALM
Unit fail, WS input signal lost.
TX PWR ALM
ODU transmitting power decreased
TX IN ALM
Receiving TX IF signal level decreased
RX IN ALM
Receiving signal level decreased
APC ALM
ODU APC loop is out of lock
MAINT ALM
LCT set to MAINT status
6.6

Indication

LED Indication on the equipment front
Failure indication of the equipment unit to be replaced.
1+0 Equipment
LED indication
MAINT
ODU ALM
IDU ALM
PWR
: 240(W) x 243(H) x 124(D) : Approx. 5 Kg (Type 1)
: 260(W) x 410(H) x 190(D) : Approx. 10 Kg (Type 2)
: 482(W) x 44(H) x 292(D) : Approx. 5 Kg*
: 482(W) x 133(H) x 300(D) : Approx. 13 Kg*
Event conditions
Condition
During Maintenance
ODU equipment failure
IDU equipment failure
On power
- 25 -
+
PASOLINK
155 MB 1+0/1+1 SYSTEM
ALM indication
LED
LED on Module panel
IDU ALM and LED on Module
panel
IDU ALM and LED on Module
panel
IDU ALM
IDU ALM
IDU ALM
IDU ALM
ODU ALM
ODU ALM
ODU ALM
ODU ALM
MAINT
Color
Yellow
Red
Red
Green

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents