Figure 18 Test Assignment List

You may quit the test at any time by clicking on the "Quit Test" button.
IMPORTANT.
When the test is complete, you will still be in the Test Mode. So you MUST go to
the Test Setup, enter your Name and log out. Click on Test Set up, and then click on Log Out.

4.0 Group Listening

To teach with PAT in a classroom or auditorium, the Classroom Infrared Emitter (Cat. No. 718-
0015), the SimulScope Bedside Auscultation System (Cat. No. 718-7003), the Auditorium
Infrared Sound System (Cat. No.718-4006) or the CardioSim Digital Heart Sound Teaching
System is recommended. With the SimulScope or Classroom Infrared Emitter, each listener
must wear a Heartman
Infrared Headphone (Cat. No. 718-7040). A low frequency speaker
system may also be used; however, speakers of any kind do not reproduce heart sounds well.
Speakers can be connected by inserting the appropriate cable into the Headphone Output Jack
(Figure 2).
4.1 Group Listening with the Classroom Infrared Emitter
Connect the output of the supplied E-Scope Electronic Stethoscope to the input of the
Classroom Infrared Emitter using the supplied cable. The output is on the side of SAM (see
Figure 2). The instructor and each student must wear a Heartman
Infrared Headphone. Place
the E-Scope on SAM in the appropriate anatomical location. The sounds will be heard by the
instructor and students simultaneously. Also,
4.2 Group Listening with the SimulScope
The SimulScope System is designed for group listening in a classroom or at the bedside. The
typical System is supplied with six Heartman
Infrared Headphones. More can be added, if
desired, up to a maximum of about 25.
The SimulScope is a small, portable, battery-operated (and/or line-operated), wireless infrared
transmitter that picks up heart, lung and bowel sounds and transmits them via infrared energy to
the wireless Heartman
headphone worn by each listener. The headphone senses the infrared
signal and converts it into an audible sound. Each headphone has its own volume control.
After PAT has been set up (see section 2.0), place the stethoscope of the SimulScope on the
manikin at the appropriate anatomical site. Each listener wearing a Heartman
Infrared
.
Headphone hears the sounds
Adjust the volume of the SimulScope to maximum
volume, then adjust the volume control knob on the HeartMan Headphone to a comfortable
listening level.