Panasonic AG-RT850P Service Manual page 67

Time lapse recorder
Hide thumbs Also See for AG-RT850P:
Table of Contents

Advertisement

2. AUTO OFF AND ERROR MESSAGE
ERROR CODE
CONDENSATION
d
FRONT LOADING
E-2
E-3
LOADING LOCKED
E-4
CYLINDER LOCKED
E-5
T-MODE
6H
L12
L24
48,72
96,120
168,180,240
CONTENS
1.
2.
(DEW)
3.
4.
1.
2.
LOACKED
1.
2.
1.
1.
REEL LOCKED
MODE
PLAY
CUE/REV
CUE/REV
PLAY
PLAY
PLAY
PLAY
CAUSE CONDITION
If it is in POWER OFF mode, the mode turns to POWER ON and "d"
blink indication.
If a tape is inserted, the mode turns to half EJECT position and
cylinder rotates.
Dew condensation continues for about 80 minutes.
After released from condensation, if a tape is inserted, the mode
turns to STOP.
If the motor is locked for about 2-5 seconds during front loading, it is
unloaded.
After above item1 if it is locked for about 2-5 seconds again, the
mode turns to AUTO OFF and "E-2" indication.
If the motor is locked for about 5 seconds during loading, it is
unloaded. Then if it is loaded and locked again, the mode turns to
AUTO OFF and "E-3" indication.
If the motor is locked for about 2-5 seconds during unloading, the
mode turns to AUTO OFF and "E-3" indication.
If the motor is locked for about 5 seconds in cylinder rotating mode,
the mode turns to AUTO OFF and "E-4" indication.
If the reel rotation is locked during tape running, the motor in
unloaded once. Then if the rotation is locked through the trying to
load, the mode turns to AUTO OFF and "E-5" indication.
TAPE SPEED
±1
±2.5
±11,21,27
+1
+1
+1
+1
INF-5
DET. TIME
3.5S
1.6S
0.3S
21S
42S
168S
336S

Advertisement

Table of Contents
loading

Table of Contents