(7) Mode 4:
Service Data 1: The second recent fault indication code is displayed.
Service Data 2: Indicate complementary data (VCR mode, mechanism position and so on) for the most recent
fault indication code.
(8) Mode 5:
Service Data 1: The third recent fault indication code is displayed.
Service Data 2: Indicate complementary data (VCR mode, mechanism position and so on) for the most recent
fault indication code.
(9) Mode 6:
Service Data 1: Check cylinder motor circuit.
Indicate if the system control IC has received the command to rotate the cylinder motor.
Service Data 2: Check capstan motor circuit.
Indicate if the system control IC has received the command to rotate the cylinder motor.
(10)Mode 7: Check the loading/unloading mechanism action.
The loading motor rotates for loading when the "PLAY" button is pressed.
The loading motor rotates for unloading when the "STOP" button is pressed.
This mode can be displayed until the POWER button is pressed.