THE INSTALLATION SPACE
All models may be used freestanding.
NOTE: If installing between frameless cabinets, a 1/2"
wide filler strip or side panel may be needed on the
hinge side. The filler strip will act as a spacer between
the door case and adjacent cabinet and will prevent in-
terference with the cabinet door swing. The width of the
opening must include the filler panels.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is re-
quired. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall as shown. Electrical must be located on
rear wall as shown.
NOTE: GFCI (ground fault circuit interrupter) is not
recommended.
• Products must operate from separate, properly ground-
ed receptacles.
Black or Stainless Steel Toekick Options
• These products are shipped with a stainless steel
toekick and a black toekick. For shipping purposes, one
of the toe kicks will be secured to the back of the unit,
and the second will be installed on the unit. Keep the
unused toekick and any unused parts for future use.
6
Design Guide
For models ZDWI240, ZDWR240, ZDBI240, ZDBR240
SIDE-BY-SIDE INSTALLATIONS
For a complete refreshment center, Install a fresh food
refrigerator beside a Double-Drawer refrigerator, Bever-
age Center, or Wine Chiller/Wine Reserve.
• A side by side installation requires minimum width
openings depending on if the product will be flush or
standard mounted and if there are stainless or custom
panels. See chart below.
• For a standard installation: The product must be
installed so that the product front will project forward
of the adjacent cabinets by the dimensions T or U
according to the model in the chart. This position will
allow a full door swing and prevent interference with
adjacent cabinetry. The opening between cabinets
must be a minimum of dimension K.
Panel
Mount Depth Style
Stainless
Flush
Stainless
Standard
Custom
Standard (only)
NOTE: To minimize interference when products are
placed side by side, adjust door swing to put hinges
farthest away from each other and handles closest to
each other. Please consult model availability to ensure
Minimum width