CM
.
Indication
The alarm code LCM, below the peripheral module (PM) subsystem header,
indicates a line concentrating module minor alarm. The number that
precedes LCM is the number of LCMs with a minor alarm.
Meaning
The indicated number of LCMs have one or more faulty drawers. An LCM
that has one or more faulty drawers is in in-service trouble (ISTb).
Impact
Lines in a drawer that is system busy (S) or manual busy (M) are line
module busy (LMB), and subscribers are without service.
Common procedures
None
Action
The following flowchart is a summary of this procedure. Use the
instructions in the step-action table that follows the flowchart to perform the
procedure.
MS
IOD
Net
.
.
.
PCM30 Line Drawer Maintenance Guide BCS33 and up
Alarm clearing procedures 3-3
Alarm clearing procedures 3-3
PM
CCS
Lns
1LCM
.
.
PM LCM
PM LCM
(continued)
Minor
Minor
Trks
Ext
APPL
.
.
.
Need help?
Do you have a question about the DMS-100 Series and is the answer not in the manual?
Questions and answers