SPSR-115/230
Self-Powered Sensor
TTL Pulse Output
15 Columbia Drive
Amherst, NH 03031 USA
Phone: (603) 883-3390 • Fax: (603) 886-3300
Email:
support@monarchinstrument.com
Website:
www.monarchinstrument.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPSR-115/230 and is the answer not in the manual?

Questions and answers

Summary of Contents for MONARCH INSTRUMENT SPSR-115/230

  • Page 1 Instruction Manual SPSR-115/230 Self-Powered Sensor TTL Pulse Output 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 • Fax: (603) 886-3300 Email: support@monarchinstrument.com Website: www.monarchinstrument.com...
  • Page 2 CYCLED in accordance with local regulations; contact your local authorities for more information. This product may be returnable to your distributor for recycling; con- tact the distributor for details. Monarch Instrument’s Limited Warranty applies. www.monarchinstrument.com for details. Warranty Registration and Extended Warranty Coverage information is...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ............1 FUNCTIONS AND OPERATION .......... 1 SPSR Interface Module ..........1 2.1.1 Connections ............ 2 2.1.2 Controls ............ 2 2.1.3 Recharging the Batteries ........ 3 3.0 SPSR-115/230 SERIES - SPSR-IM WITH ROS-P ..... 3 ROS-P ................ 3 3.2 Operating the SPSR as a Triggering Source .... 4 4.0 BATTERY DISPOSAL ............ 4 5.0 SPECIFICATIONS ............. 5 6.0 SENSORS/OPTIONS AND ACCESSORIES ......8...
  • Page 4: Introduction

    Universal Recharger The SPSR-115/230 is comprised of the SPSR-IM Interface Module, which provides power to a sensor and couples the sensor to a BNC output; an input sensor with a visible red LED light source (ROS-P); and a battery recharger.
  • Page 5: Connections

    2.1.1 Connections Connect the input sensor via the 1/8” [3.5 mm] phone plug to the mating connector on the SPSR-IM. This sensor may remain connected even when recharging the internal batteries of the SPSR-IM. NOTE: Do not plug an input sensor into the SPSR with the Power switch in the ON position.
  • Page 6: Recharging The Batteries

    Allow up to 4 hours to fully charge. 3.0 SPSR-115/230 SERIES - SPSR-IM WITH ROS-P The SPSR-115/230 consists of the SPSR-IM Interface Module described above, an ROS-P Remote Optical Sensor with eight foot cable and mounting bracket, and an SPSR-U (115/230 V ac) external power connection. One foot of T-5 Reflective Tape is also supplied.
  • Page 7: Operating The Spsr As A Triggering Source

    For most applications, a 1/2" square piece of T-5 Reflective Tape should be applied to a clean area on the rotating object. The sensor should be mounted and optically aligned to illuminate the reflective target once per revolution. It is recommended that the optical sensor be placed at a slight angle (approximately 10-15 degrees) from perpendicular, so that the sensor will detect only the reflected pulses from the target.
  • Page 8: Specifications

    5.0 SPECIFICATIONS Specifications* SPSR-IM Interface Module Internal Batteries Nickel metal hydride (NiMH) battery pack, 4.8 V dc Operating Interval >40 hours typical with ROS-P ( ~ 40 mA load) Charge Time Up to 4 hours TTL compatible pulse, INVERTED or NON-INVERTED switch selectable With ROS (negative pulse) input, output will be a Output positive pulse when set to inverted or negative pulse...
  • Page 9 Specifications* ROS-P Remote Optical Sensor Operating Envelope Up to 3 ft. [0.9 m] and 45° from reflective target Speed Range 1 to 250,000 RPM Illumination Source Visible red LED, 5 V dc @ 30 mA Operating Temperature 14 °F to 158 °F (-10 °C to 70 °C) Output Signal 5 to 0 V dc TTL compatible pulse On-Target Indicator...
  • Page 10 5.1 Compliance Both the SPSR-IM and ROS-P units are CE compliant. • Low Voltage Directive (LVD) 2014/35/EU • Electromagnetic Compatibility Directive (EMC) 2014/30/EU • Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU...
  • Page 11: Sensors/Options And Accessories

    6.0 SENSORS/OPTIONS AND ACCESSORIES ROS-P Remote Optical Sensor with 8 ft. [2.5 m] cable and mounting bracket PN: 6180-057 ROS-P-25 Remote Optical Sensor with 25 ft. [7.6 m] cable PN: 6180-057-25 and mounting bracket ROLS-P Remote Optical Laser Sensor with 8 ft. [2.5 m] cable and mounting bracket PN: 6180-029 IRS-P...
  • Page 12 The Professional’s Choice Monarch Instrument is committed to excellence and quality in manufacturing, sales, and service. Track-It Data Loggers Panel Tachometers Portable ™ Tachometers Frequency Portable Strobes Fixed Mounted Converters Strobes Speed Sensors DataChart Paperless ™ Recorders 15 Columbia Drive, Amherst NH 03031 USA Tel.: (603) 883-3390 // Fax: (603) 886-3300...