Page 2
Manufacturer Safe Use Guidance Class 2 lasers are considered safe Monarch Instrument for accidental eye exposure. Do 15 Columbia Drive not look or stare into beam. Do Amherst, NH 03031 USA not aim at aircraft.
ROLS24-W-25 24VDC ±10% 25 feet tinned wires 2.0 MODELS WITH STEREO PLUG The ROLS-P and ROLS-P-25 models have an 8-foot or 25-foot length cable ending with a 3.5mm [1/8 in] stereo plug connection. These models will work directly with all Monarch handheld tachometers and stroboscopes that accept pulse input through an input jack (e.g.
3.0 MODELS WITH TINNED WIRES The ROLS-W, ROLS24-W and ROLS24-W-25 models have an 8-foot or 25-foot length cable ending with tinned wires. These models will work directly with all Monarch panel instruments that accept pulse inputs (e.g. ACT Series, Frequency to Analog Converters, DataChart™...
(15 degrees) from perpendicular, so that the sensor will receive only pulses from the reflective marker. Triggering from contrasting colors should be done perpendicular to the target. The ROLS should be at least 1 inch from the reflective target to avoid false triggering. The green LED On-Target Indicator will blink at the input frequency rate when the ROLS is properly aimed.
5.0 SPECIFICATIONS Specifications* ROLS ROLS24 Speed Range 1-250,000 RPM Illumination Visible Red Laser, Class 2 Laser Specifications: Class 2 (per IEC 60825-1:2014) This product complies with IEC60825-1 Ed. 3 and Classification 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50 of June 2007...
Specs ROLS ROLS24 continued Operating Temperature 14°F to 158°F (-10°C to 70°C) Maximum relative humidity 80% for temperature up Humidity to 88°F (31°C), decreasing linearly to 50% relative humidity at 104°F (40°C) 1/8 in. (3.5 mm) male Connection stereo plug or tinned...
Need help?
Do you have a question about the ROLS and is the answer not in the manual?