COMPR
NO. 1
VOLTAGE
RANGE
RLA
LRA
414-508
34.6
173.0
LEGEND
CV
— Constant Volume
ETL
— ETL Testing Laboratory
FLA
— Full Load Amps
Hp
— Nominal Horsepower
IFM
— Indoor (Evaporator) Fan Motor
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps (for wire sizing)
MOCP — Maximum Overcurrent Protection
OFM
— Outdoor (Condenser) Fan Motor
RLA
— Rated Load Amps
*Electric heat available on 50 Series vertical discharge units.
†108 kW available on CV applications only.
Table 4 — Electrical Data, 044 Units (cont)
COMPR
OFM
IFM
NO. 2
Total
RLA
LRA
Hp
FLA
7.5
10.0
34.6
173.0
8.1
15.0
20.0
460-3-60 (V-Ph-Hz)
BASE UNIT
ONLY
Total
FLA
MCA
MOCP
Hp
6.0
10.0
15.0
6.0
11.0
96.9
125
6.0
6.0
10.0
10.0
10.0
15.0
15.0
15.0
6.0
10.0
15.0
6.0
14.0
99.9
125
6.0
6.0
10.0
10.0
10.0
15.0
15.0
15.0
6.0
10.0
15.0
6.0
21.0
106.9
125
6.0
6.0
10.0
10.0
10.0
15.0
15.0
15.0
6.0
10.0
15.0
6.0
27.0
112.9
125
6.0
6.0
10.0
10.0
10.0
15.0
15.0
15.0
NOTES:
1. Electric resistance heaters are rated at 208/240 v, 480 v, or 575 v. To
determine heater capacity (kW) at unit operating voltage, multiply 240 v,
480 v, or 575 v capacity by appropriate multiplier below.
HEATER kW
RATING
240
480
575
Electric heaters are tested and ETL approved at maximum
total external static pressure of 1.9 in. wg.
2. Boldface indicates 48 and 50 Series units. All other data is for 50 Series
units only.
23
EXHAUST
ELECTRIC
FAN
HEAT*
Total
kW
FLA
FLA
9.6
15.2
22.0
36
46.3
72
93.0
108†
139.0
9.6
36
46.3
9.6
72
93.0
9.6
108†
139.0
15.2
36
46.3
15.2
72
93.0
15.2
108†
139.0
22.0
36
46.3
22.0
72
93.0
22.0
108†
139.0
9.6
15.2
22.0
36
46.3
72
93.0
108†
139.0
9.6
36
46.3
9.6
72
93.0
9.6
108†
139.0
15.2
36
46.3
15.2
72
93.0
15.2
108†
139.0
22.0
36
46.3
22.0
72
93.0
22.0
108†
139.0
9.6
15.2
22.0
36
46.3
72
93.0
108†
139.0
9.6
36
46.3
9.6
72
93.0
9.6
108†
139.0
15.2
36
46.3
15.2
72
93.0
15.2
108†
139.0
22.0
36
46.3
22.0
72
93.0
22.0
108†
139.0
9.6
15.2
22.0
36
46.3
72
93.0
108†
139.0
9.6
36
46.3
9.6
72
93.0
9.6
108†
139.0
15.2
36
46.3
15.2
72
93.0
15.2
108†
139.0
22.0
36
46.3
22.0
72
93.0
22.0
108†
139.0
MULTIPLICATION FACTORS
VOLTAGE
MULTIPLICATION
DISTRIBUTION
FACTOR
V-3-60
200
208
230
240
440
460
480
550
575
600
BASE UNIT WITH
EXHAUST FAN
AND/OR
ELECTRIC HEAT*
MCA
MOCP
106.5
125
112.1
125
118.9
150
96.9
125
130.0
150
187.5
200
106.5
125
130.0
150
187.5
200
112.1
125
130.0
150
187.5
200
118.9
150
130.0
150
187.5
200
109.5
125
115.1
125
121.9
150
99.9
125
133.7
150
191.2
200
109.5
125
133.7
150
191.2
200
115.1
125
133.7
150
191.2
200
121.9
150
133.7
150
191.2
200
116.5
150
122.1
150
128.9
150
106.9
125
142.5
175
200.0
200
116.5
150
142.5
175
200.0
200
122.1
150
142.5
175
200.0
200
128.9
150
142.5
175
200.0
200
122.5
150
128.1
150
134.9
150
112.9
150
150.0
200
207.5
225
122.5
150
150.0
200
207.5
225
128.1
150
150.0
200
207.5
225
134.9
150
150.0
200
207.5
225
0.694
0.751
0.918
1.000
0.840
0.918
1.000
0.915
1.000
1.089