Generator Configuration Screen - Whisper Power WhisperTouch WP 5.0 inch User Manual

Remote control panel
Table of Contents

Advertisement

WhisperPower Touch Display
WP 5.0, 7.0 and 10.0 inch
13
On the Energy Config screen settings are provided for the WPC and WPC-BSI (shunt) con-
nections. For direct connection the option Interface has to be set to RS232, the connection
to the WPC and WPC-BSI is made through the WPC-RS232-I interface which is not included
(Order Number 60201084). For more complex configurations with more than one display and
for maritime settings, contact WhisperPower for more information. The System Setup option
is provided for the WPC configuration, SINGLE for one WPC, PARALLEL for more than one
WPC's in a parallel configuration and 3-PHASE for 3 WPC's in a 3-phase configuration.
3.2.9 Generator Config screen
On the generator config screen settings are provided for the generator connection. For the
WhisperPower Touch Display the only setting for system is WhisperPower. For a direct con-
nection to the generator DDC interface has to be set to RS485. A second option NMEA2000
is provided for more complex configurations with more than one display and for maritime
settings, contact WhisperPower for more information. The Energy Button option is provided
to change the text on the Energy Button. The option 'AC from WPC' is provided for generators
without a voltage measuring coil, the output voltage/current/power and frequency are meas-
ured by the WPC in this case.