Whisper Power WhisperTouch WP 5.0 inch User Manual

Remote control panel

Advertisement

Quick Links

User Manual
Remote Control Panel
WhisperTouch
E n j o y G r e e n E n e r g y
WP 5.0 inch | WP 7.0 inch | WP 10.0 inch
whisperpower.com

Advertisement

Table of Contents
loading

Summary of Contents for Whisper Power WhisperTouch WP 5.0 inch

  • Page 1 User Manual Remote Control Panel WhisperTouch E n j o y G r e e n E n e r g y WP 5.0 inch | WP 7.0 inch | WP 10.0 inch whisperpower.com...
  • Page 2 WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch...
  • Page 3: Table Of Contents

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch Table of contents Introduction Firmware Revision WPCI2000 Features (Touch display) Quick Install Installation Mounting the WP Touch Display Connecting the WP Touch Display Checking Connections Configuring the WhisperPower Touch Display WhisperPower Touch Display screens 3.2.3 GENERATOR screen 3.2.4 SETTINGS screen...
  • Page 4: Introduction

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch Introduction Congratulations on your purchase of the WhisperPower Touch Display, displaying WPC in- verter/ battery charger information, precise battery monitoring and/or WhisperPower Genera- tor information. The WhisperPower Touch Display is available in 3 sizes: a 5 inch WP 5.0 Touch (order number 40280100), the 7 inch WP 7.0 Touch (order number 40280101).
  • Page 5: Quick Install

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch Quick Install Installing the WhisperPower wpXXarm Touch Display involves the following steps. Please refer to the individual sections for additional details. 1. Unpack the Box (Section 2.2) 3. Mount the Touch Panel (Section 2.3) 4.
  • Page 6 WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch The WhisperPower Touch Displays provide a connection to a WPC-RS232-i serial interface and a RS485 connection for the generator; these connections can be found on the back of the device. The device is powered by an external power source ranging from 6-42V DC.
  • Page 7 WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch WhisperPower Touch Display WP 5.0 inch Rear-side used ➜ ➜ ➜ - ➜ ➜ + ➜ + Generator RS232-i RS232-i WhisperPower Centre WhisperPower Centre WhisperPower Touch Display WP 7.0 inch Rear-side Generator Generator ➜...
  • Page 8: Checking Connections

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch 2.5 Checking Connections Once the connection to the WPC-RS232-i interface and the connection to the generator have been completed, power can be supplied to the WhisperPower Touch Display. Check to see that information is being properly transmitted by observing the ENERGY screen and/or the GENERATOR screen.
  • Page 9: Generator Screen

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch 3.2.2 ENERGY screen To set the current limit Charger only Charger + inverter (combi mode) On the Energy screen the WPC status is shown. Input and output voltage and current, battery voltage and current of the shunt and WPC (optional), charge state and remaining time of the battery.
  • Page 10: Settings Screen

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch 3.2.4 SETTINGS screen On the Settings screen the in user mode buttons are shown to access the Maintenance, Authorization, Display and System screens. After entering the appropriate Maintenance pass- word the buttons Start Screen, Lock Brand, Energy Config, Generator Config, WPC Settings, BSP Settings and WP Genset Settings are unlocked.
  • Page 11: Settings Screen In Installer Mode

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch USER LEVEL PASSWORD User Basic 0000 Expert 1234 Installer level 1 8051 Extra Warning: Improper settings can make the installation inoperable and/or damage the installation. To go back to User Level ‘User’ : enter nothing in the text box and press ‘Verify’. Once user level is set, you need to go back to the main menu for further actions 3.2.6 Settings screen in Installer mode On the Settings screen in Installer mode all additional buttons are unlocked.
  • Page 12: Authorization Screen

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch 3.2.7 Authorization screen On the Authorization screen a password can be set to access the WhisperPower Touch Display’s webserver. After entering the IP address of the display a authorization display pops up, the default user is admin and the default password is also admin.
  • Page 13: Generator Configuration Screen

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch On the Energy Config screen settings are provided for the WPC and WPC-BSI (shunt) con- nections. For direct connection the option Interface has to be set to RS232, the connection to the WPC and WPC-BSI is made through the WPC-RS232-I interface which is not included (Order Number 60201084).
  • Page 14: Display Screen

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch 3.2.10 Display screen On the Display screen settings are provided for the screensaver and the dimming of the screen. The screensaver can be turned on and off and a screensaver time out can be set. The dimming can be set on and off and a dimming level can be set for day and night conditions.
  • Page 15: Auto Starting The Generator

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch be set when the display is entering the secure mode. If the option Use PIN code is turned on a password has to be entered to return from security mode. 3.2.12 System screen On the system screen a button is provided to reboot the WhisperPower Touch Display.
  • Page 16: Troubleshooting

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch Troubleshooting SYMPTOM TROUBLESHOOTING PROCEDURE Check the connections to the WhisperPower Touch Display. Screen doesn’t turn on Ensure that power is supplied to the 6-42V DC connection. Check the RS232 connection from the WPC-RS232-I interface to No WPC data the WhisperPower Touch Display.
  • Page 17: Dimensions

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch Dimensions WP 5.0 WP 5.0 WP 7.0 WP 7.0 WP10.0...
  • Page 18: Technical Specifications

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch 7. Technical Specifications As WhisperPower is constantly improving its products, all specifications are subject to change without notice Electrical PARAMETER VALUE COMMENT Operating Voltage 6 to 42 Volts Power Consumption 100 to 240 mA Mechanical PARAMETER VALUE...
  • Page 19: Technical Support

    WhisperPower Touch Display WP 5.0, 7.0 and 10.0 inch Technical Support If you require technical support for WhisperPower products, you can reach us in any of the following ways: Telephone: +31 (0) 512 571 550 E-mail: sales@whisperpower.com World Wide Web: www.whisperpower.com...
  • Page 20 E n j o y G r e e n E n e r g y WhisperPower BV Kelvinlaan 82, 9207 JB Drachten The Netherlands www.whisperpower.com sales@whisperpower.com...

Table of Contents