Fault
Freezer compartment door
was open tor a long time;
temperature is no longer
reached.
Possible cause
The evaporator (refrigeration
generator) in the No Frost
system is covered in thick ice
and can no longer be defrosted
fully automatically.
Remedial action
T o defrost the evaporator,
remove the frozen food with the
compartments, insulate well and
store in a cool location.
Switch off the appliance and move
it away from the wall. Leave the
appliance door open.
After approx. 20 min. the
condensation begins to run into the
m,
evaporation pan, Fig.
of the appliance. To prevent the
evaporation pan from overflowing in
!his case, mop up the condensation
with a sponge.
The evaporator is defrosted when
the water stops running into the
evaporation pan. cıean the interior.
Switch the appliance back on again.