Advertisement

Quick Links

INSTALLER MANUAL
Pellet Stove
EN
©2019 CADEL srl | All rights reserved - Tutti i diritti riservati
GRACE
- SPIRIT
- MADISON - TABLA - ROXY - ATRIUM - SOLO 5
3
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GRACE3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cadel GRACE3

  • Page 1 INSTALLER MANUAL Pellet Stove ©2019 CADEL srl | All rights reserved - Tutti i diritti riservati GRACE - SPIRIT - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 2: Table Of Contents

    6.1 INTRODUCTION .............24 6.2 FUME CONDUIT CLEANING ........25 6.3 FUME PASSAGES CLEANING ........25 6.4 HOW TO CLEAN THE ROOM FAN ......26 6.5 FUME PIPES ANNUAL CLEANING ......27 GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 3: Manual Simbology

    European Standards (EN 15287 - EN 13384 - EN 1856 - EN 1443) and UNI 10683:2012. It provides instructions for a good and correct execution of the chimney flue but it does not absolutely replace the current stan- GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 4: Chimney Flue

    Height over the ridge of the roof = 0,5 mt Roof inclination ≥ 10° 90° Measured distance at 90° from the roof surface = 1,3 mt GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 5: Height-Depression

    • Have your chimney flue and chimney pot checked and cleaned by an expert chimney sweep at least once a week. The chimney sweep has to release a written declaration about the security of the system. • Not cleaning compromise safety. GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 6: Chimney Pot

    Fig. 5 - Chimney components LEGEND Fig. 5 Chimney pot Fume outlet Chimney flue Termal insulation External wall Chimney union Fume pipe Heat generator Inspection door T-union with inspection plug GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 7: Chimney Flue Connection

    In any case, strictly follow the product/installation requirements of the relative regulations/ legislation in force in that country. EXAMPLES OF CORRECT INSTALLATION Fig. 6 - Example 1 GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 8 • Old chimney flue with an inserted pipe of minimum Ø100/120 mm and with an external door which enables the chimney cleaning. Fig. 8 - Example 3 GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 9: Combustion Air

    • The air inlet must be realized at a height close to the floor with an external grid against birds. In such a way it cannot be ob- structed by any object. • In case of installation with sealed-chamber the air inlet is not necessary. GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 10: Combustible Air Inlet For Sealed-Chamber

    In some countries and/or regions the installation with sealed-chamber is obligatory: in case of doubt, please follow the most restrictive regulations. COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATION How to connect to the stove in the sealed chamber with concentric system: GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 11: Installation

    • To install more appliances, the external air inlet must be correctly dimensioned (see FEATURES a pag. 31). OVERALL DIMENSIONS Fig. 12 - General dimensions: Spirit LEGEND Fig. 12 60 cm 95,5 cm GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 12 17,3 cm 79,5 cm 6,6 cm 76 cm 13,2 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 14 - General dimensions: Atrium GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 13 13,5 cm 17,1 cm 29,8 cm 19,7 cm 76 cm 17,3 cm 76 cm 13,2 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 14 12,5 cm 14,5 cm 30 cm 18,7 cm 76 cm 16,5 cm 76 cm 13,2 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 15: General Installation

    • If the walls are made up of flammable materials, check the safety distances (see Fig. 19). • At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary please install a fire GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 16: Stove Door Removal/Installation

    • Once the frame is made (see Fig. 25), hook it to the stove using the special teeth (see Fig. 26). • Lock the frame with 2 screws (see Fig. 27). GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 17 • Take the stone and fit the screw head in the appropriate hole in the brackets (see Fig. 32 and Fig. 33). • Proceed in the same way for all the stones (see Fig. 34). • Follow the procedure in reverse order to remove. GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 18 • Take the glasses and fit the screw head in the appropriate hole in the brackets (see Fig. 39 and Fig. 40). • Proceed in the same way for all the glasses (see Fig. 41). • Follow the procedure in reverse order to remove. GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 19: Frame Disassembly Spirit

    • Remove the 2 screws of the faceplates located under and above the door (see Fig. 44 and Fig. 45) and then take them out (see Fig. 46). GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 20: Upper Exhaust Grace

    • Once the passage is open, insert the d.80 mm pipe of the smoke exhaust (see Fig. 51). Fig. 50 - Remove grid Fig. 51 - Insert pipe GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 21: Assembly Of The Grace Pedestal

    The stove is suitable for wall mounting. The can be attached to a load-bearing wall in masonry (NOT plasterboard, wood, etc...) suitable for the entire weight of the stove. Fig. 56 - Wall mounting GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 22 Fig. 59 - Step 3 RIF. GRACE Hole d.120 mm for fumes extraction Hole d.80 mm for combustion air inlet Wall support Metal dowels Clamping bracket Screw GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 23: 5.11 Electric Connection

    • Press the "menu" button. • Scroll with the arrows to "Settings". • Select by pressing "menu". • Scroll with the arrows again to "Ext.Thermostat". • Select by pressing "menu". GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 24: 5.14 Stove Calibration And Depression Measurement

    All these operations must be planned in time with your Autorized Technical Assistance Service. • After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust. GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 25: Fume Conduit Cleaning

    • Remove the door and the front coating (see dedicated chapters). • Loosen the screws and remove the inspection cap (see Fig. 64). • Vacuum the ash accumulated inside (see Fig. 65). GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 26: How To Clean The Room Fan

    • The room fan is fixed to the back of the stove, to remove it loosen the 4 screws behind the stove (see Fig. 70). • Remove the fan and vacuum the ash and dust accumulated in the fan (see Fig. 71). GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 27: Fume Pipes Annual Cleaning

    In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to avoi irreparable damages! GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 28 The auger geared motor is out of Replace the geared motor. order Check if on the display there is an Have the stove checked. "ACTIVE ALARM" GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 29 Not sealed fume and/or for replacing pipes with those in compliance to current pipes regulations. A not sealed fume channelisation can be noxious to health. GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 30 When this flashing message appears upon start-up, it means tenance alert (it display showing that the preset operating hours have elapsed before mainte- does not block the "SERVICE" nance. Contact the service centre. system) GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 31: Technical Datas

    (vedi Fig. 74).To assembly proceed at the contrary. Fig. 73 - Remove the screws Fig. 74 - Remove the screw GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 32: Features

    40 / 300 / 0 mm 40 / 300 / 0 mm DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front) - / 1000 mm - / 1000 mm - / 1000 mm GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 33 40 / 300 / 0 mm 40 / 300 / 0 mm DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front) - / 1000 mm - / 1000 mm - / 1000 mm GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 34 40 / 300 / 0 mm 40 / 300 / 0 mm DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front) - / 1000 mm - / 1000 mm - / 1000 mm GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 35 EXTERNAL AIR INLET FOR SEALED CHAMBER 60 mm DISTANCE FROM COMBUSTIBLE MATERIAL (back/side/bottom) 40 / 300 / 0 mm DISTANCE FROM COMBUSTIBLE MATERIAL (ceiling/front) - / 1000 mm GRACE3 - SPIRIT3 - MADISON - TABLA - ROXY - ATRIUM - SOLO 5...
  • Page 36 Rev. 02 - 2020 CADEL srl www.cadelsrl.com 31025 S. Lucia di Piave - TV www.free-point.it Via Foresto sud, 7 - Italy www.pegasoheating.com Tel. +39.0438.738669 Fax +39.0438.73343...

This manual is also suitable for:

Spirit3MadisonTablaRoxyAtriumSolo 5